1 November 2011 in Journal of the American Academy of Audiology
Background:Recently, a number of popular media articles have raised some concern that portable listening devices (PLDs) may be increasing the risk for music-induced hearing loss (MIHL). However, literature regarding adolescents’ listening behavior and how their attitudes and beliefs relate to behavior is currently limited.Purpose:The purposes of this study were (1) to investigate the relationship between volume control settings and output levels of PLDs, (2) to examine how adolescents’ listening behavior changes as a function of background noise and noise isolation, (3) to investigate the relationship between self-reported listening levels and laboratory-measured listening levels, and (4) to evaluate the validity of the Listening Habits Questionnaire as a research tool for evaluating how attitudes and beliefs relate to PLD use behavior.Research
Design:A descriptive study. Experiment 1 evaluated the output levels of a set of PLDs, and Experiment 2 characterized the listening behavior and attitudes toward PLD use of a group of adolescents.Study Sample:Twenty-nine adolescents aged 13‐17 yr, with normal hearing, participated in Experiment 2.Data Collection and Analysis:Experiment 1 evaluated the output levels of a set of PLDs with stock and accessory earphones using an acoustic manikin. Experiment 2 included survey measures of listening behavior and attitudes as well as output levels measured using a probe microphone.Conclusions:The output levels of PLDs are capable of reaching levels that could increase the risk for MIHL, and 14% of teenagers in this study reported behavior that puts them at increased risk for hearing loss. However, measured listening levels in the laboratory settings did not correlate well with self-reported typical listening levels. Further, the Listening Habits Questionnaire described in this study may provide a useful research tool for examining the relationship between attitudes and beliefs and listening behavior.
1 February 2016 in Adolescent Health, Medicine and Therapeutics
Hearing loss from the overuse of portable listening devices (PLDs), such as MP3 players or iPods, is of great concern in the popular media. This review aims to discuss the current state of scientific knowledge about music-induced hearing loss from PLD use. This report evaluates the literature on the risk to hearing from PLD use, the individual and psychological factors that influence PLD usage, and strategies for reducing exposure to music through PLDs. Specific interventions are reviewed, and several recommendations for designing interventions and for individual intervention in clinical practice are presented. Clinical recommendations suggested include the “80–90 rule” and the use of isolator-style earphones to reduce background noise.
1 September 2017 in Journal of the American Academy of Audiology
Background:Vestibular-evoked myogenic potentials (VEMPs) are commonly used clinical assessments for patients with complaints of dizziness. However, relatively high air-conducted stimuli are required to elicit the VEMP, and ultimately may compromise safe noise exposure limits. Recently, research has reported the potential for noise-induced hearing loss (NIHL) from VEMP stimulus exposure through studies of reduced otoacoustic emission levels after VEMP testing, as well as a recent case study showing permanent sensorineural hearing loss associated with VEMP exposure.Purpose:The purpose of this report is to review the potential for hazardous noise exposure from VEMP stimuli and to suggest clinical parameters for safe VEMP testing.Research Design:Literature review with presentation of clinical guidelines and a clinical tool for estimating noise exposure.Results:The literature surrounding VEMP stimulus-induced hearing loss is reviewed, including several cases of overexposure. The article then presents a clinical calculation tool for the estimation of a patient’s safe noise exposure from VEMP stimuli, considering stimulus parameters, and includes a discussion of how varying stimulus parameters affect a patient’s noise exposure. Finally, recommendations are provided for recognizing and managing specific patient populations who may be at higher risk for NIHL from VEMP stimulus exposure. A sample protocol is provided that allows for safe noise exposure.Conclusions:VEMP stimuli have the potential to cause NIHL due to high sound exposure levels. However, with proper safety protocols in place, clinicians may reduce or eliminate this risk to their patients. Use of the tools provided, including the noise exposure calculation tool and sample protocols, may help clinicians to understand and ensure safe use of VEMP stimuli.
4 February 2013 in International Journal of Audiology
Objective: This study was designed to evaluate the usage patterns of portable listening device (PLD) listeners, and the relationships between self-report measures and long-term dosimetry measures of listening habits. Design: This study used a descriptive correlational design. Study sample: Participants (N = 52) were 18–29 year old men and women who completed surveys. A randomly assigned subset (N = 24) of participants had their listening monitored by dosimetry for one week. Results: Median weekly noise doses reported and measured through dosimetry were low (9–93%), but 14.3% of participants reported exceeding a 100% noise dose weekly. When measured by dosimetry, 16.7% of participants exceeded a 100% noise dose weekly. The self-report question that best predicted the dosimetry-measured dose asked participants to report listening duration and usual listening level on a visual-analog scale. Conclusions: This study reports a novel dosimetry system that can provide accurate measures of PLD use over time. When not feasible, though, the self-report question described could provide a useful research or clinical tool to estimate exposure from PLD use. Among the participants in this study, a small but substantial percentage of PLD users incurred exposure from PLD use alone that increases their risk of music-induced hearing loss.
1 January 2016 in Trends in Hearing
In patients with bilateral hearing loss, the use of two hearing aids (HAs) offers the potential to restore the benefits of binaural hearing, including sound source localization and segregation. However, existing evidence suggests that bilateral HA users’ access to binaural information, namely interaural time and level differences (ITDs and ILDs), can be compromised by device processing. Our objective was to characterize the nature and magnitude of binaural distortions caused by modern digital behind-the-ear HAs using a variety of stimuli and HA program settings. Of particular interest was a common frequency-lowering algorithm known as nonlinear frequency compression, which has not previously been assessed for its effects on binaural information. A binaural beamforming algorithm was also assessed. Wide dynamic range compression was enabled in all programs. HAs were placed on a binaural manikin, and stimuli were presented from an arc of loudspeakers inside an anechoic chamber. Stimuli were broadband noise bursts, 10-Hz sinusoidally amplitude-modulated noise bursts, or consonant–vowel–consonant speech tokens. Binaural information was analyzed in terms of ITDs, ILDs, and interaural coherence, both for whole stimuli and in a time-varying sense (i.e., within a running temporal window) across four different frequency bands (1, 2, 4, and 6 kHz). Key findings were: (a) Nonlinear frequency compression caused distortions of high-frequency envelope ITDs and significantly reduced interaural coherence. (b) For modulated stimuli, all programs caused time-varying distortion of ILDs. (c) HAs altered the relationship between ITDs and ILDs, introducing large ITD–ILD conflicts in some cases. Potential perceptual consequences of measured distortions are discussed.
1 July 2015 in Otology & Neurotology
Cervical and ocular vestibular evoked myogenic potentials (cVEMPs and oVEMPs) are commonly used in evaluation of neurotologic disorders. We present a case of sudden bilateral hearing loss immediately after oVEMP and cVEMP testing. The hearing loss did not recover. To our knowledge, no previous case reports discuss sudden hearing loss, especially bilateral, associated with VEMP testing. A single patient with sudden bilateral hearing loss that has persisted after cVEMP and oVEMP. The patient had a history of chronic daily dizziness. She underwent vestibular function testing that included cVEMP and oVEMP testing. A significant bilateral sensorineural hearing loss was noted immediately after cVEMP and oVEMP testing and confirmed with audiometric testing. Despite the use of oral steroids, her hearing loss did not recover. Serial audiograms, calculated maximum total sound energies to each ear. Pre-VEMP versus post-VEMP audiograms show increased thresholds and decreased word recognition scores; total sound energy delivered to each ear shows significant sound exposure. Although VEMP testing is thought to be safe and well tolerated, a significant amount of sound can be delivered to the cochlea, and certain individuals may be susceptible to acoustic trauma at these levels. We recommend limits for VEMP stimuli levels and attention to total sound exposure when multiple trials are used.