Laboni Rani Keya

Laboni Rani Keya

Auto-generated profile, based on publicly available information

Laboni Rani Keya

Department of EEE, Mymensingh Engineering College (University of Dhaka), Mymensingh-2000

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2026 in Solar Energy
Verified
Journal Article
Closed access
ASAsadul Islam Shimul
Asadul Islam Shimul
BBBipul Chandra Biswas
Bipul Chandra Biswas
LKLaboni Rani Keya
Laboni Rani Keya
SISahjahan Islam
Sahjahan Islam
MRMd.AZizur Rahman
Md.AZizur Rahman
NENoureddine Elboughdiri
Noureddine Elboughdiri

13 March 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
MFMotiur Rahman Foysal
Motiur Rahman Foysal
BDBrinta Dey
Brinta Dey
MAM. Ahmed
M. Ahmed
LKLaboni Keya
Laboni Keya
SHS.M.A. Haque
S.M.A. Haque
The present study introduces a novel design and analysis of a sensor based on a terahertz metamaterial absorber (MMA) to identify Glioblastoma cell by employing microwave imaging techniques. Terahertz (THz) frequencies offer unique advantages for biomedical applications. Computer Simulation Technology (CST) employs a finite integration (FIT) approach to simulate the suggested structure in the resonant frequency (RF) range of 4.5 THz to 6 THz. The crystal structure displays three distinct absorption peaks at resonance frequencies. The MTA can absorb energy in three specific spectral bands: 4.782 THz, 5.30 THz, and 5.7319 THz. At these frequencies, the MTM achieves exceptionally high absorption, reaching 99.99%, 99.98%, and 99.68% peak absorption, respectively. The electric field (E), magnetic field (H), and surface current of the MTM are also examined. Finally, detecting Glioblastoma cells is also being investigated by analyzing the E-field H-field using microwave imaging. The suggested biosensor features a high-quality factor of 143.63, a frequency shifts per refractive index of 1.45 THz/RIU. In this study, the PCR value is measured at 0.95 at a frequency of 4.782 THz, indicating a high efficiency in polarization conversion. Polarization Conversion Ratio (PCR) quantifies the efficiency of a metamaterial in converting the polarization of an incident electromagnetic wave. Extensive simulation studies confirm the sensor’s capability to distinguish between healthy and cancerous cervical tissue. The suggested MMA-based sensor has numerous advantages and can be utilized for Glioblastoma cell detection.