Monika Bjelčić

Monika Bjelčić

Auto-generated profile, based on publicly available information

Monika Bjelčić

BioMAX Beamline, MAX IV Laboratory, Lund University, Sweden

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2023 in IUCrJ
Verified
Journal Article
Open access
PDF file
FLFilip Leonarski
Filip Leonarski
JNJie Nan
Jie Nan
ZMZdenek Matej
Zdenek Matej
QBQuentin Bertrand
Quentin Bertrand
AFAntonia Furrer
Antonia Furrer
FDFlorian Dworkowski
Florian Dworkowski
Serial and time-resolved macromolecular crystallography are on the rise. However, beam time at X-ray free-electron lasers is limited and most third-generation synchrotron-based macromolecular crystallography beamlines do not offer the necessary infrastructure yet. Here, a new setup is demonstrated, based on the JUNGFRAU detector and Jungfraujoch data-acquisition system, that enables collection of kilohertz serial crystallography data at fourth-generation synchrotrons. More importantly, it is shown that this setup is capable of collecting multiple-time-point time-resolved protein dynamics at kilohertz rates, allowing the probing of microsecond to second dynamics at synchrotrons in a fraction of the time needed previously. A high-quality complete X-ray dataset was obtained within 1 min from lysozyme microcrystals, and the dynamics of the light-driven sodium-pump membrane protein KR2 with a time resolution of 1 ms could be demonstrated. To make the setup more accessible for researchers, downstream data handling and analysis will be automated to allow on-the-fly spot finding and indexing, as well as data processing.

29 July 2024 in IUCrJ
Verified
Journal Article
Open access
PDF file
ADA. Dunge
A. Dunge
CPC. Phan
C. Phan
OUO. Uwangue
O. Uwangue
MBM. Bjelcic
M. Bjelcic
JGJ. Gunnarsson
J. Gunnarsson
GBG. Brändén
G. Brändén
Structure-based drug design is highly dependent on the availability of structures of the protein of interest in complex with lead compounds. Ideally, this information can be used to guide the chemical optimization of a compound into a pharmaceutical drug candidate. A limitation of the main structural method used today – conventional X-ray crystallography – is that it only provides structural information about the protein complex in its frozen state. Serial crystallography is a relatively new approach that offers the possibility to study protein structures at room temperature (RT). Here, we explore the use of serial crystallography to determine the structures of the pharmaceutical target, soluble epoxide hydrolase. We introduce a new method to screen for optimal microcrystallization conditions suitable for use in serial crystallography and present a number of RT ligand-bound structures of our target protein. From a comparison between the RT structural data and previously published cryo-temperature structures, we describe an example of a temperature-dependent difference in the ligand-binding mode and observe that flexible loops are better resolved at RT. Finally, we discuss the current limitations and potential future advances of serial crystallography for use within pharmaceutical drug discovery.

4 April 2025 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
AGAna Gonzalez
Ana Gonzalez
TKTobias Krojer
Tobias Krojer
JNJie Nan
Jie Nan
MBMonika Bjelčić
Monika Bjelčić
SASwati Aggarwal
Swati Aggarwal
MTMarjolein M. G. M. Thunnissen
Marjolein M. G. M. Thunnissen
The first multi-bend achromat based synchrotron MAX IV operates two protein crystallography beamlines, BioMAX and MicroMAX. BioMAX is designed as a versatile, stable, high-throughput beamline catering for most protein crystallography experiments. MicroMAX is a more ambitious beamline dedicated to serial crystallography including time-resolved experiments. Both beamlines exploit the special characteristics of fourth-generation beamlines provided by the 3 GeV ring of MAX IV. In addition, the fragment-based drug discovery platform, FragMAX, is hosted and, at the FemtoMAX beamline, protein diffraction experiments exploring ultrafast time resolution can be performed. A technical and operational overview of the different beamlines and the platform is given as well as an outlook for protein crystallography embedded in the wider possibilities that MAX IV offers to users in the life sciences.

9 March 2023 in Journal of Applied Crystallography
Verified
Journal Article
Open access
PDF file
SGSwagatha Ghosh
Swagatha Ghosh
DZDoris Zorić
Doris Zorić
PDPeter Dahl
Peter Dahl
MBMonika Bjelčić
Monika Bjelčić
JJJonatan Johannesson
Jonatan Johannesson
RNRichard Neutze
Richard Neutze
Serial femtosecond crystallography was initially developed for room-temperature X-ray diffraction studies of macromolecules at X-ray free electron lasers. When combined with tools that initiate biological reactions within microcrystals, time-resolved serial crystallography allows the study of structural changes that occur during an enzyme catalytic reaction. Serial synchrotron X-ray crystallography (SSX), which extends serial crystallography methods to synchrotron radiation sources, is expanding the scientific community using serial diffraction methods. This report presents a simple flow cell that can be used to deliver microcrystals across an X-ray beam during SSX studies. This device consists of an X-ray transparent glass capillary mounted on a goniometer-compatible 3D-printed support and is connected to a syringe pump via lightweight tubing. This flow cell is easily mounted and aligned, and it is disposable so can be rapidly replaced when blocked. This system was demonstrated by collecting SSX data at MAX IV Laboratory from microcrystals of the integral membrane protein cytochrome c oxidase from Thermus thermophilus, from which an X-ray structure was determined to 2.12 Å resolution. This simple SSX platform may help to lower entry barriers for non-expert users of SSX.

1 November 2023 in Acta Crystallographica Section D Structural Biology
Verified
Journal Article
Open access
PDF file
MBMonika Bjelčić
Monika Bjelčić
KCKajsa G. V. Sigfridsson Clauss
Kajsa G. V. Sigfridsson Clauss
OAOskar Aurelius
Oskar Aurelius
MMMirko Milas
Mirko Milas
JNJie Nan
Jie Nan
TUThomas Ursby
Thomas Ursby
In recent years, the emergence of serial crystallography, initially pioneered at X-ray free-electron lasers (XFELs), has sparked a growing interest in collecting macromolecular crystallographic data at room temperature. Various fixed-target serial crystallography techniques have been developed, ranging from commercially available chips to in-house designs implemented at different synchrotron facilities. Nevertheless, there is currently no commercially available chip (known to the authors) specifically designed for the direct handling of oxygen-sensitive samples. This study presents a methodology employing silicon nitride chips arranged in a `sandwich' configuration, enabling reliable room-temperature data collection from oxygen-sensitive samples. The method involves the utilization of a custom-made 3D-printed assembling tool and a MX sample holder. To validate the effectiveness of the proposed method, deoxyhemoglobin and methemoglobin samples were investigated using the BioMAX X-ray macromolecular crystallography beamline, the Balder X-ray absorption spectroscopy beamline and UV–Vis absorption spectroscopy.

8 April 2025 in Archives of Biochemistry and Biophysics
Verified
Journal Article
Open access
OUOwens Uwangue
Owens Uwangue
JGJohan Glerup
Johan Glerup
ADAndreas Dunge
Andreas Dunge
MBMonika Bjelcic
Monika Bjelcic
GWGabrielle Wehlander
Gabrielle Wehlander
GBGisela Brändén
Gisela Brändén
The cytochrome P450 family of enzymes are key players in the metabolism of foreign substances in the body, including pharmaceutical compounds, and therefore important to take into consideration during drug development. The main human isoform is CYP3A4, a highly flexible protein that can act on a diverse set of substances and that is inhibited by compounds varying greatly in size. To accompany the different ligands, substantial conformational changes occur that transform the active-site binding pocket between a collapsed form and various open states. A large body of biophysical data including high-resolution structures are available but there is still a lack of understanding of the dynamic properties of CYP3A4. Here, we present the first room-temperature structure of CYP3A4 solved by serial crystallography. The structure is overall very similar to structures solved at cryo-temperature of the un-bound form of the enzyme including the conformation of the active-site lid. We observe that loops are better defined at room-temperature despite the lower resolution of this structure. Based on an internal distance matrix analysis of a large set of CYP3A4 structures, we conclude that the crystal form rather than temperature is determining for how the structures cluster. Finally, a workflow for generating microcrystals suitable for fixed-target serial crystallography data collection is described. This work lays the foundation for future studies of ligand-induced dynamics and structural transitions during the catalytic reaction of CYP3A4.