Yuliia Bezuhla

Yuliia Bezuhla

Auto-generated profile, based on publicly available information

Yuliia Bezuhla

National University of Civil Defence of Ukraine

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2021 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
BPBoris Pospelov
Boris Pospelov
VAVladimir Andronov
Vladimir Andronov
EREvgenіy Rybka
Evgenіy Rybka
MSMikhail Samoilov
Mikhail Samoilov
OKOlekcii Krainiukov
Olekcii Krainiukov
EKEduard Kochanov
Eduard Kochanov
A method for operational forecasting of fires is proposed that enables the sequential implementation of five procedures. The method development is necessary to predict early fires in premises in order to take measures to prevent them from escalating into an uncontrolled combustion phase ‒ a fire. As a result of research, it was found that a short-term forecast of the recurrence of increments of the air conditions by one step, based on the current measure of recurrence, is an effective indicator of early fires in premises. At the same time, it was found that before the moment of ignition of the material, the state of the air environment is characterized by dynamic stability, which is described by an irregular and time-dependent random change in the recurrence of the states of the vector of current increments of the state of the air environment. The values of the indicated levels of recurrence of the state increments are determined by the probability levels of 0.67 and 0.1, respectively. The probability of recurrence of state increments of 0.67 is characteristic of a larger number of measured states. When the material is ignited, the dynamics of the probability of recurrence of state increments change abruptly. There is a transition from two to one level of recurrence, close to zero probability ‒ the loss of dynamic stability (in the region of count 250). Further dynamics are characterized by the appearance of separate random recurrent increments corresponding to the instability of the air environment in the premises. In the course of the experiment, it was found that the accuracy of predicting a fire by the proposed method ranges from 4.48 % to 12.79 %, which generally indicates its efficiency. The obtained data prove useful in the development of new systems that early warn of fire in premises, as well as in the modernization of existing systems and means of fire protection of premises

30 August 2021 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
BPBoris Pospelov
Boris Pospelov
EREvgenіy Rybka
Evgenіy Rybka
OKOlekcii Krainiukov
Olekcii Krainiukov
OYOleksandr Yashchenko
Oleksandr Yashchenko
YBYuliia Bezuhla
Yuliia Bezuhla
ONOleksandr Nepsha
Oleksandr Nepsha
This paper reports the rationale for the modification of Brown’s zero-order model, which ensures increased accuracy of the short-term fire forecast based on the use of the current measure of recurrence in the increments of the state of the air environment in the premises. A special feature of the proposed model modification is that the a priori model of the dynamics of the level of the time series of the measure of the current recurrence of increments in the air environment states determined by the dangerous factors of the fire has been modified. In this case, it is proposed that the new a priori model should take into consideration additionally the value of the current increments of the level of the studied time series. That makes it possible to negligibly reduce errors of the short-term forecast of fire in the premises without significantly complicating Brown’s zero-order model while retaining all its implementing advantages. The provided accuracy of the forecast for one step in advance on the basis of a time series of measures of the current recurrence of increments of the state of the air environment, determined from the experimental data during the ignition of alcohol and timber in a laboratory chamber, has been investigated. The considered quantitative indicators of forecast accuracy are the absolute and average errors exponentially smoothed with a parameter of 0.4. It has been established that for the proposed modification the value of the average absolute error does not exceed 0.02 %. That means that an error of the short-term forecast of a fire in the premises based on the proposed modification is an order of magnitude less than that in the case of using known Brown’s model at the smoothing parameter from an unclustered set. The results from the ignition of alcohol and timber in the laboratory chamber, in general, indicate significant advantages of using the proposed modification of Brown’s zero-order model for a short-term forecast of a fire in the premises.

30 June 2022 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
VSVolodymyr Sadkovyi
Volodymyr Sadkovyi
BPBoris Pospelov
Boris Pospelov
EREvgenіy Rybka
Evgenіy Rybka
BKBorys Kreminskyi
Borys Kreminskyi
OYOleksandr Yashchenko
Oleksandr Yashchenko
IKIryna Kozynska
Iryna Kozynska
The object of this study is the detection of fires in the premises. The problem that was solved is the development of tools to assess the reliability of detection of fires in the premises based on the recurrence of the vector of increases in dangerous parameters of the gas environment. The method includes the sequential implementation of five procedures related to the formation of the vector of current increases in dangerous parameters, determining the recurrence of the current vector and evaluating the empirical distribution function relative to the calculated current recurrence of the state vector. Features and distinctive attributes of the developed method are the use of empirical cumulative distribution function in relation to the current recurrence of the state of hazardous parameters of the gas environment in the premises during fires. This makes it possible to solve the task of developing tools for the numerical determining of the trust limit for the predefined level of significance (reliability) and the likelihood of detecting fires in the premises in real time. The scope and conditions for the practical use of the obtained results are the modern and promising means and fire protection systems of various types of premises in buildings and structures. The proposed method was tested on the example of igniting test materials in the laboratory chamber. It is established that for materials with a high combustion rate (alcohol and cellulose) with a probability of 0.95, there is a sharp decrease in the value of the empirical function assessment to zero values. For timber, the value of this estimate is 0.15, and for textiles, the minimum value of the estimate is 0.31. It is established that the boundaries of the confidence interval with the level of significance covering the obtained estimates are determined by the value of ±0.086. In general, the results of the test indicate the operability of the proposed method for determining the reliability of detection of fires in the premises on the basis of the current degree of recurrence of increases in dangerous parameters of the gas environment

29 February 2020 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
BPBoris Pospelov
Boris Pospelov
RMRuslan Meleshchenko
Ruslan Meleshchenko
OKOlekcii Krainiukov
Olekcii Krainiukov
KKKostiantyn Karpets
Kostiantyn Karpets
OPOlena Petukhova
Olena Petukhova
EKEduard Kochanov
Eduard Kochanov
A method for preventing the emergency resulting from fires in the premises through operative control over a gas medium

30 April 2022 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
BPBoris Pospelov
Boris Pospelov
EREvgenіy Rybka
Evgenіy Rybka
MSMikhail Samoilov
Mikhail Samoilov
IMIhor Morozov
Ihor Morozov
YBYuliia Bezuhla
Yuliia Bezuhla
JVJulia Veretennikova
Julia Veretennikova
This paper theoretically substantiates research into the spectral features of the dynamics of the main dangerous parameters of a gas environment when igniting materials in a laboratory chamber. Studying such spectral features is based on the calculation of the direct discrete Fourier transform for discrete measurements, equal in number, over the current intervals of observation of the hazardous examined parameter of the gas medium before and after the material is ignited. In this approach, a Fourier discrete transform makes it possible to determine the instantaneous amplitude and phase spectra for the time intervals under consideration. This makes it possible to explore the peculiarities of the distribution of amplitudes and phases of harmonic components in the spectrum of the dynamics of dangerous parameters of the gas environment before and after the ignition of materials. The results of experimental studies established that the nature of the amplitude spectrum is low-informative and not sensitive enough to fires. The main contribution to the amplitude spectrum of the dynamics of the investigated hazardous parameters of the gas environment in the chamber is made by the frequency components in the range of 0–0.2 Hz. The contribution to the amplitude spectrum of frequency components over 0.2 Hz is insignificant and decreases with increasing frequency. It is established that from the phase spectrum, the nature of the random scattering of phases for frequency components exceeding 0.2 Hz is informative. It was found that the nature of the phase spread for these frequency components in the spectrum depends on the type of ignition material. The results reported here could prove useful when devising new effective technologies for detecting fires in the premises of objects in various fields to protect against fires. This is explained by the fact that for the detection of fires in the premises, high-frequency components are important, characterized by the increase in dangerous parameters of the gas environment

30 June 2021 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
BPBoris Pospelov
Boris Pospelov
EREvgenіy Rybka
Evgenіy Rybka
RMRuslan Meleshchenko
Ruslan Meleshchenko
OKOlekcii Krainiukov
Olekcii Krainiukov
IBIgor Biryukov
Igor Biryukov
RVRuslan Vasylchenko
Ruslan Vasylchenko
Possibilities of parameterization of the zero-order Brown model for indoor air forecasting based on the current measure of air state gain recurrence are considered. The key to the zero-order parametric Brown forecasting model is the selection of the smoothing parameter, which characterizes forecast adaptability to the current air state gain recurrence measure. It is shown that for effective short-term indoor fire forecast, the Brown model parameter must be selected from the out-of-limit set defined by 1 and 2. The out-of-limit set for the Brown model parameter is an area of effective fire forecasting based on the measure of current indoor air state gain recurrence. Errors of fire forecast based on the parameterized zero-order Brown model in the case of the classical and out-of-limit sets of the model parameters are investigated using the example of ignition of various materials in a laboratory chamber. As quantitative indicators of forecast quality, the absolute and mean forecast errors exponentially smoothed with a parameter of 0.4 are investigated. It was found that for alcohol, the smoothed absolute and mean forecast errors for the classical smoothing parameter in the no-ignition interval do not exceed 20 %. At the same time, for the out-of-limit case, the indicated forecast errors are, on average, an order of magnitude smaller. Similar ratios for forecast errors remain in paper, wood and textile ignition. However, for the transition zone corresponding to the time of material ignition, a sharp decrease in the current measure of chamber air state gain recurrence is observed. It was found that for this zone, the smoothed absolute forecast error for alcohol is about 2 % if the model parameter is selected from the classical set. If the model parameter is selected from the out-of-limit set, the forecast error is about 0.2 %. The results generally demonstrate significant advantages of using the zero-order Brown parametric model with out-of-limit model parameters for indoor fire forecasting