Xinyi Cheng

Xinyi Cheng

Auto-generated profile, based on publicly available information

Xinyi Cheng

University of Texas Southwestern Medical Center

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2023 in View
Verified
Journal Article
Open access
MLMengting Li
Mengting Li
SWSheng Wang
Sheng Wang
QKQunshou Kong
Qunshou Kong
XCXinyi Cheng
Xinyi Cheng
HYHuanhuan Yan
Huanhuan Yan
DJDawei Jiang
Dawei Jiang
In recent years, radiometals have been successfully applied to medicine because of their breadth of decay properties and increased production and availability. Bifunctional chelators play a key role in radiometal‐based radiopharmaceuticals, affecting the labeling, targeting, and pharmacokinetics of bioconjugations and ensuring the stable complexation of the metal in vivo. The capacity of macrocycles to form complexes with extremely high thermodynamics, kinetics, and stability compared to acyclic chelators continues to pique the curiosity of pharmacists and biochemists among all prospective chelators utilized for the radiometal chelation. As new imaging modalities and therapeutic targets develop, the discovery of novel ligand structures with suitable chemical and biological features encourages the modification of chelators with charge and chemical properties. Herein, we present a comprehensive review of developments of macrocyclic chelators for PET radiopharmaceuticals, including innovative chelating agents with new structures and known chelating agent modifications, and their physical‐chemical properties, as well as their biological characteristics and applications in vivo.

19 October 2021 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
XCXinyi Cheng
Xinyi Cheng
KHKun Hu
Kun Hu
DYDongxu Yang
Dongxu Yang
YSYiping Shao
Yiping Shao
Objective: In contrast to clinical radiation therapy (RT) that ubiquitously uses PET/CT image to accurately guide RT, all current commercial animal irradiators can only provide CT image-guided preclinical RT that severely limits their capability for preclinical and compatibility for translational radiation oncology research. To address this problem, we have developed a compact and lightweight PET with uniform, high spatial resolution that is suited to be installed inside an existing animal irradiator for potential onboard PET/CT image-guided preclinical RT research. Approach: The design focused on the balance of achieving sufficient imaging performance for practical preclinical RT guidance with constrained size and weight. The detector head consists of a ring of 12 detector panels in a dodecagon configuration and 12 front-end electronics boards that are closely attached to the detector panels. The overall size and weight of the detector head are 33.0 cm diameter, 11.0 cm axial length and ∼6.5 kg weight that can be installed inside an existing irradiator. Each detector panel has a 30 × 30 array of 1 × 1 × 20 mm 3 LYSO scintillators with depth-of-interaction (DOI) measurement. The front-end electronics boards process and convert detected signals to digital signals and transfer them to system electronics and data acquisition located outside the irradiator through low-voltage-differential-signaling cables. Main results: The typical energy, DOI and coincidence timing resolutions are around 22.1%, 3.1 mm, and 1.92 ns. The imaging field-of-view (FOV) is 8.0 cm diameter and 3.5 cm axial length. The performance evaluations show a 1.8% sensitivity at the center FOV, uniform ∼1.1 mm resolution within 6 cm diameter FOV, and all rods of 1.0 mm diameter can be clearly resolved from the image of an ultra-micro hot-rods phantom. Significance: Overall, this compact and lightweight PET has demonstrated its designed capability and performance sufficient for providing onboard functional/biological/molecular image to guide the preclinical RT research.

6 October 2016
Verified
Conference Paper
Closed access
YWYonggang Wang
Yonggang Wang
CLChong Liu
Chong Liu
XCXinyi Cheng
Xinyi Cheng
DLDeng Li
Deng Li
According to the technical requirement of the time coincident measurement for TOF-PET systems, an eight-channel wave-union time-to-digital convertor (TDC) based on a Spartan-6 Xilinx FPGA has been implemented and tested. The root-mean-square (RMS) error of the two channels on the same FPGA measuring a fixed time interval is less than 14 ps, while the RMS error of the two channels inter-FPGA is less than 26.5 ps. The TDC measurement dead time is only 8 ns, which is conducive to the trigger mechanism combining a low threshold for timing and a high threshold for event confirmation. Because the time coincidence measurements in PET scanners always occur between the opposing TDC circuits, the variation of the RMS error and measured mean value by the two inter-FPGA TDC channels in different temperature environments is also presented.

16 February 2021 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
XCXinyi Cheng
Xinyi Cheng
KHKun Hu
Kun Hu
DYDongxu Yang
Dongxu Yang
YSYiping Shao
Yiping Shao
For positron emission tomography (PET) online data acquisition, a centralized coincidence processor (CCP) with single-thread data processing has been used to select coincidence events for many PET scanners. A CCP has the advantages of highly integrated circuit, compact connection between detector front-end and system electronics and centralized control of data process and decision making. However, it also has the drawbacks of data process delay, difficulty in handling very high count-rates of single and coincidence events and complicated algorithms to implement. These problems are exacerbated when implementing a CCP on a field-programable-gate-array (FPGA) due to increased routing congestion and reduced data throughput. Industry companies have applied non-centralized or distributed data processing to solve these problems, but those solutions remain either proprietary or lack full disclosure of technical details that make the techniques unclear and difficult to adapt for most research communities. In this study, we investigated the use of a set of distributed coincidence processors (DCP) that can address the CCP problems and be implemented relatively easily. Each coincidence processor exclusively connects one detector pair and selects coincidence events from this detector pair only, which breaks a centralized coincidence process to a collection of independent and parallel processes. DCP can significantly minimize the data process delay, maximize count-rates of coincidence events and simplify implementation by implementing a single coincidence processor with one detector pair and replicating it to the rest. A prototype DCP with 42 coincidence processors was implemented on an off-the-shelf FPGA development board for a small PET with 12 detectors configured with 42 detector pairs. DCP performances were tested with both pulsed signals and gamma ray interactions. There was no coincidence data loss up to the detector’s maximum singles count-rate (250 k s −1 ). Approximately 1.2 k registers were utilized for each coincidence processor and the FPGA resource utilization was proportional to the number of coincidence processors. Coincidence timing spectra showed the results from accurately acquired coincidence events. In conclusion: complementary to CCP, DCP can provide high count-rate capability, with a simplified algorithm for implementation and potentially a practical solution for online acquisition of a PET with a larger number of detector pairs or for ultrahigh-throughput imaging.

26 May 2022 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
XCXinyi Cheng
Xinyi Cheng
DYDongxu Yang
Dongxu Yang
YZYuncheng Zhong
Yuncheng Zhong
YSYiping Shao
Yiping Shao
Purpose. Although positron emission tomography (PET) can provide a functional image of static tumors for RT guidance, it’s conventionally very challenging for PET to track a moving tumor in real-time with a multiple frame/s sampling rate. In this study, we developed a novel method to enable PET based three-dimension (3D) real-time marker-less tumor tracking (RMTT) and demonstrated its feasibility with a simulation study. Methods. For each line-of-response (LOR) acquired, its positron-electron annihilation position is calculated based on the time difference between the two gamma interactions detected by the TOF PET detectors. The accumulation of these annihilation positions from data acquired within a single sampling frame forms a coarsely measured 3D distribution of positron-emitter radiotracer uptakes of the lung tumor and other organs and tissues (background). With clinically relevant tumor size and sufficient differential radiotracer uptake concentrations between the tumor and background, the high-uptake tumor can be differentiated from the surrounding low-uptake background in the measured distribution of radiotracer uptakes. With a volume-of-interest (VOI) that closely encloses the tumor, the count-weighted centroid of the annihilation positions within the VOI can be calculated as the tumor position. All these data processes can be conducted online. The feasibility of the new method was investigated with a simulated cardiac-torso digital phantom and stationary dual-panel TOF PET detectors to track a 28 mm diameter lung tumor with a 4:1 tumor-to-background 18FDG activity concentration ratio. Results. The initial study shows TOF PET based RMTT can achieve 30 s acquisition time to achieve the same tracking accuracy. Conclusion. With the demonstrated feasibility, the new method may enable TOF PET based RMTT for practical RT applications.