Lukas Koester

Lukas Koester

Auto-generated profile, based on publicly available information

Lukas Koester

Institute for Renewable Energy, EURAC Research, Viale Druso 1, I-39100 Bolzano, Italy, Italy

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2022 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Open access
LKL. Koester
L. Koester
Sascha LindigSascha Lindig
Sascha Lindig
ALA. Louwen
A. Louwen
AAA. Astigarraga
A. Astigarraga
GMG. Manzolini
G. Manzolini
DMDavid Moser
David Moser

23 November 2023 in Solar RRL
Verified
Journal Article
Open access
LKLukas Koester
Lukas Koester
ALAtse Louwen
Atse Louwen
Sascha LindigSascha Lindig
Sascha Lindig
Giampaolo ManzoliniGiampaolo Manzolini
Giampaolo Manzolini
DMDavid Moser
David Moser
Daylight photoluminescence (DPL) is a relatively novel imaging technique utilized in photovoltaic (PV) system inspection, using the sun as excitation source. Filtering the luminescence signal from the strong sun irradiation is its main challenge. Images acquired at two different operating points (OPs) of the module, allow subtraction of the background radiation while maintaining the luminescence signal. A DPL‐ready inverter, which is able to toggle between manually selectable OPs of connected PV modules, is presented in this work. Synchronization of image acquisition and OP switching becomes particularly challenging if the camera is applied to unmanned aerial vehicles. To overcome this challenge, an algorithm is developed to identify OP switches in a set of images taken in the field by investigating image intensities. Further, by working out the detailed dependencies of the signal recorded during DPL, the temperature coefficient of photoluminescence intensity is derived theoretically, and its impact on quantitative inspections. The potential field application of DPL images to identify performance loss in PV modules is investigated by two approaches: recording the signal intensity of images over time and comparing the signal intensity of different PV modules in one image. For both approaches, their hypothetical applicability is shown experimentally.

16 March 2023 in EPJ Photovoltaics
Verified
Journal Article
Open access
PDF file
LKLukas Koester
Lukas Koester
EVEmanuel Vallarella
Emanuel Vallarella
ALAtse Louwen
Atse Louwen
Sascha LindigSascha Lindig
Sascha Lindig
DMDavid Moser
David Moser
The application of electroluminescence imaging of photovoltaic modules increased in the last years, due to the reliable and detailed identification of degradation and failures. In future plants the time-consuming connection of power supplies could be overcome by use of inverters with bi-directional functionality, allowing backpowering of connected module strings directly. Temperature influences the open-circuit voltage of photovoltaic modules and must therefore be considered during backpowering. This work investigates the heating due to backpowering of photovoltaic modules of different types during electroluminescence inspection. The temperature increase until saturation is estimated by energy balance calculations and experimentally verified to be around 20 °C, with resulting voltage drops of up to 3 V. Further, these changes have an effect on the recorded luminescence intensity: a decrease of the electroluminescence signal intensity between beginning of backpowering and reaching saturation temperature is shown. For application of the results to a real-world scenario, the electroluminescence window of an electroluminescence-ready inverter is introduced, giving the boundaries of current and voltage that can be supplied. Combined with a simulation of the dark current–voltage curves of a connected photovoltaic module string, the electroluminescence inspection possibilities are visualized. Finally, the applicability of this heating phenomenon for snow melting is discussed.

17 April 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
MMMarco Memminger
Marco Memminger
AMAlessandro Minini
Alessandro Minini
JVJordi Veirman
Jordi Veirman
GBGiovanni Borz
Giovanni Borz
MPMartina Pelle
Martina Pelle
DMDavid Moser
David Moser
Agrivoltaics (Agri-PV) represents a promising solution to improve land-use efficiency by simultaneously allowing crop growth and photovoltaic (PV) energy generation, with additional benefits for crop production if properly engineered. However, when crystalline silicon (c-Si) PV modules are used for Agri-PV, even in semi-transparent configurations, shading occurs over crops, potentially reducing agricultural yields. Enhancing light diffusion is a key strategy to partially compensate for this effect, as diffuse light is more efficiently utilized by most plants. This study aims at engineering the transparent section of a semi-transparent c-Si PV module, assessing its optical, light-scattering, and efficiency-related properties for Agri-PV applications. The experimental work involved fabricating and testing various transparent stack configurations and mini-module prototypes to evaluate their suitability for Agri-PV integration. Optical characterization using a spectrophotometer revealed that certain stack configurations significantly enhance light diffusion, while maintaining good transmittance values for crops growth. To further analyze angular light scattering, a custom-built setup to measure the Bidirectional Transmittance Distribution Function (BTDF) was developed. The results showed that primarily anti-glare films (AG) and secondarily specific encapsulants (TPO) and flexible layers can effectively improve light distribution, helping to mitigate shading effects. Following AG application, Haze values exceeded 89%, indicating enhanced light diffusion capabilities. The impact of different stacks on module efficiency was also assessed through mini-modules testing. Findings indicate that enhanced light diffusion can be achieved with minimal efficiency losses. Specifically, the application of the AG resulted in a reduction of the Cell-To-Module efficiency ratio (CTMη) of less than 1%. These results confirm that semi-transparent PV modules can be optimized for Agri-PV applications without significantly compromising energy output.