Lizhi Cui

Lizhi Cui

Auto-generated profile, based on publicly available information

Lizhi Cui

National and Local Joint Engineering Laboratory for Optical Conversion Materials and Technology of National Development and Reform Commission, School of Materials and Energy, Lanzhou University, Lanzhou, 730000, China

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2024 in Science Advances
Verified
Journal Article
Open access
LCLizhi Cui
Lizhi Cui
ZDZhijie Dong
Zhijie Dong
DYDechao Yu
Dechao Yu
YWYuhua Wang
Yuhua Wang
AMAndries Meijerink
Andries Meijerink
The use of lanthanide luminescence has advanced the field of remote temperature sensing. Luminescence intensity ratio methods relying on emission from two thermally coupled energy levels are popular but suffer from a limited temperature range. Here, we present a versatile luminescent thermometer: Ba(Sr)FBr(Cl):Sm 2+ . The Sm 2+ ion benefits from multiple thermally coupled excited states to extend the temperature range and has strong parity-allowed 4f 6 →4f 5 5d 1 absorption to increase brightness. We conduct a comparative analysis of the temperature sensing performance of Sm 2+ in BaFBr, BaFCl, SrFBr, and SrFCl and address the role of concentration, host, and Boltzmann equilibration. Different thermal coupling schemes, 5 D 1 - 5 D 0 and 4f 5 5d 1 - 5 D 0 , and temperature-dependent lifetimes enable accurate sensing between 350 and 800 kelvin. Differences in 4f 5 5d 1 - 5 D 0 energy gap allows optimization for a temperature range of interest. This type of Sm 2+ -based thermometer holds great potential for temperature monitoring in the wide and relevant range up to 500°C.

14 February 2014 in The Journal of Physical Chemistry C
Verified
Journal Article
Open access
JMJ. A. McLeod
J. A. McLeod
DBD. W. Boukhvalov
D. W. Boukhvalov
AZAnatoly Zatsepin
Anatoly Zatsepin
RGR. J. Green
R. J. Green
BLB. Leedahl
B. Leedahl
AMA. Moewes
A. Moewes
By studying Fe-doped ZnO pellets and thin films with various X-ray spectroscopic techniques, and complementing this with density functional theory calculations, we find that Fe-doping in bulk ZnO induces isovalent (and isostructural) cation substitution (Fe2+ → Zn2+). In contrast to this, Fe-doping near the surface produces both isovalent and heterovalent substitution (Fe3+ → Zn2+). The calculations performed herein suggest that the most likely defect structure is the single or double substitution of Zn with Fe, although, if additional oxygen is available, then Fe substitution with interstitial oxygen is even more energetically favorable. Furthermore, it is found that ferromagnetic states are energetically unfavorable, and ferromagnetic ordering is likely to be realized only through the formation of a secondary phase (i.e., ZnFe2O4), or codoping with Cu.

16 October 2026 in Science Advances
Verified
Journal Article
Closed access
GZGuitong Zhang
Guitong Zhang
JWJiaPeng Wu
JiaPeng Wu
YMYixuan Ma
Yixuan Ma
LCLizhi Cui
Lizhi Cui
ZDZhijie Dong
Zhijie Dong
AMAndries Meijerink
Andries Meijerink
Mn 4+ -activated phosphors offer a unique possibility of calibration-free primary luminescence thermometry using the ratio of anti-Stokes to Stokes (AS/S) vibronic emission lines of the 2 E → 4 A 2 transition. Previous work used the AS/S emission of Mn 4+ for thermometry but always relying on fitting procedures with effective vibrational energies that deviate from actual energies. Here, we explore a strategy without prior temperature calibration using two well-known Mn 4+ -doped hosts, Mg 14 Ge 5 O 24 (MGO) and K 2 SiF 6 (KSF). In both Mn 4+ occupies octahedral sites, replacing Ge 4+ or Si 4+ , resulting in a weak zero-phonon line (ZPL) and strong vibronic Stokes and anti-Stokes lines. From the temperature-dependent emission spectra the AS/S ratios ν 6 ′/ν 6 , ν 4 ′/ν 4 , ν 3 ′/ν 3 were determined to serve as input for luminescence intensity ratio (LIR) analysis. For the well-resolved vibronic lines of Mn 4+ in KSF it is feasible to realize temperature readout without temperature calibration – a capability rarely achieved in luminescence thermometry. In contrast, for Mn 4+ in MGO vibronic lines exhibit significant overlap, complicating single-phonon-mode modeling. Even spectral deconvolution methods do not allow for reliable calibration-free temperature sensing. This work establishes a generalizable approach to optical thermometry relying on anti-Stokes/Stokes vibronic lines, offering a path towards calibration-free temperature sensing.