Peter J. Lee

Peter J. Lee

Auto-generated profile, based on publicly available information

Peter J. Lee

Florida State University

Research Focus & Metrics

Academic Career Length

42Years (1985-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 March 2014 in Nature Materials
Verified
Journal Article
Closed access
PDF file
DLD. C. Larbalestier
D. C. Larbalestier
JJJ. Jiang
J. Jiang
UTU. P. Trociewitz
U. P. Trociewitz
FKF. Kametani
F. Kametani
CSChristian Scheuerlein
Christian Scheuerlein
EHE. E. Hellstrom
E. E. Hellstrom

4 July 2008 in Superconductor Science and Technology
Verified
Journal Article
Closed access
AYA Yamamoto
A Yamamoto
APA A Polyanskii
A A Polyanskii
JJJ Jiang
J Jiang
FKF Kametani
F Kametani
CTC Tarantini
C Tarantini
ZZZ X Zhao
Z X Zhao

1 November 2009 in Diseases of the Colon & Rectum
Verified
Journal Article
Closed access
DCDong Jin Choi
Dong Jin Choi
SKSeon Hahn Kim
Seon Hahn Kim
PLPeter J. M. Lee
Peter J. M. Lee
JKJin Kim
Jin Kim
SWSi Uk Woo
Si Uk Woo
To overcome the pitfalls of laparoscopy, a robotic system has been introduced in rectal cancer surgery. However, there is no standard procedure to maximize the advantages of the da Vinci® S Surgical System. Therefore, we describe our technique of applying the robotic system during all of the steps of dissection in rectal cancer surgery and the short-term outcome. Prospectively collected data were reviewed from 50 consecutive patients who underwent single-stage, totally robotic dissection for rectal cancer resection between July 2007 and June 2008. Robotic dissection was performed following these steps: 1) ligation of the inferior mesenteric vessels and medial to lateral dissection, 2) mobilization of the sigmoid/descending/splenic flexure colon, and 3) rectal dissection. The remaining steps including rectal transection and anastomosis were performed by a conventional laparoscopic method. There were 32 (64%) men and 18 (36%) women. The mean distance from the anal verge to the tumor margin was 7.3 (range, 2–13) cm. The conversion rate was 0%. The mean operative time was 304.8 (range, 190–485) minutes, and 20.6 (range, 6–48) lymph nodes were harvested. The circumferential margin was positive in one patient. The length of hospital stay after surgery was 9.2 (range, 5–24) days. Anastomotic leak rate was 8.3%, and all of the patients with leakage were managed conservatively. Single-stage robotic dissection for rectal cancer surgery is feasible, and its short-term outcome is acceptable. Our technique can be a suitable procedure to maximize the advantages of the da Vinci® system.

27 April 2005 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
AGA. Godeke
A. Godeke
MJM. C. Jewell
M. C. Jewell
CFC. M. Fischer
C. M. Fischer
ASA. A. Squitieri
A. A. Squitieri
PLP. J. Lee
P. J. Lee
DLD. C. Larbalestier
D. C. Larbalestier
We have examined the upper critical field of a large and representative set of present multifilamentary Nb3Sn wires and one bulk sample over a temperature range from 1.4 K up to the zero-field critical temperature. Since all present wires use a solid-state diffusion reaction to form the A15 layers, inhomogeneities with respect to Sn content are inevitable, in contrast to some previously studied homogeneous samples. Our study emphasizes the effects that these inevitable inhomogeneities have on the field-temperature phase boundary. The property inhomogeneities are extracted from field-dependent resistive transitions which we find broaden with increasing inhomogeneity. The upper 90%–99% of the transitions clearly separates alloyed and binary wires but a pure, Cu-free binary bulk sample also exhibits a zero-temperature critical field that is comparable to the ternary wires. The highest μ0Hc2 detected in the ternary wires are remarkably constant: The highest zero-temperature upper critical fields and zero-field critical temperatures fall within 29.5±0.3 and 17.8±0.3K , respectively, independent of the wire layout. The complete field-temperature phase boundary can be described very well with the relatively simple Maki–DeGennes model using a two-parameter fit, independent of composition, strain state, sample layout, or applied critical state criterion.

15 December 1989 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
CMC. Meingast
C. Meingast
PLP. J. Lee
P. J. Lee
DLD. C. Larbalestier
D. C. Larbalestier
A most important step in the critical current density (Jc) optimization of Nb‐Ti is the large final drawing strain, in which α‐Ti precipitates, initially approximately equiaxed and 100–200 nm in diameter, are drawn into ribbons, whose thickness (1–2 nm) is less than the superconducting coherence length [ξ (4.2 K)∼5 nm]. Using transmission electron microscopy, the precipitate thickness, spacing, cross‐sectional area, and circumference were measured over the whole final drawing strain range. Each of these parameters was found to have a simple power dependence on the wire diameter. Tc, Hc2, and the resistivity (ρn) were also change considerably during the refinement of the precipitates. Directly after precipitation, Tc increased, and (dHc2/dT)Tc and ρn were reduced from the single‐phase values. Drawing the wire returned these parameters to their single‐phase values, as the precipitate thickness was reduced to less than ξ. This observation explains a long‐standing peculiarity in this system, namely that the optimum Hc2 of high Jc conductors occurs for a composition close to Nb 46 wt.% Ti, even when the precipitation of 18 vol % of α‐Ti shifts the matrix composition to a Nb‐rich composition of theoretically lower Hc2.

4 August 2003 in Superconductor Science and Technology
Verified
Journal Article
Closed access
MJMatthew C Jewell
Matthew C Jewell
PLPeter J Lee
Peter J Lee
DLDavid C Larbalestier
David C Larbalestier