Monitoring clogging in treatment wetlands (TW) remains challenging, as existing methods are typically non-continuous, invasive, or impractical for long-term operation. Microbial fuel cells (MFCs) have been proposed as non-invasive biosensors for clogging detection in horizontal flow treatment wetlands, exploiting natural redox gradients. However, their applicability to French vertical flow treatment wetlands (VFTW), which operate predominantly under unsaturated aerobic conditions, is unknown. This proof-of-concept study evaluates whether oxygen limitation induced by clogging in a vertical-flow (VF) filter can be indirectly detected via changes in MFC electrical output. Two air-cathode MFCs, hydraulically coupled to filtration columns, were operated in parallel, under laboratory scale. The tested-MFC received raw wastewater with a high suspended solids load to induce progressive clogging and oxygen limitation, while the control-MFC operated without imposed clogging. Over 14 days, oxygen saturation in the air-cathode chamber decreased from 100% to 0%, coinciding with a decline in current output from 0.36 to 0.14 mA. In contrast, the control MFC maintained a stable current of 0.36 mA. These results demonstrate a clear qualitative sensitivity of MFC electrical output to oxygen depletion associated with clogging under controlled VF conditions. These initial findings highlight the potential of MFCs as non-invasive, early warning biodetector for clogging in VFTW by targeting oxygen limitation as an indicator.
Clogging is considered an operational challenge in French vertical flow treatment wetlands (VFTWs), causing hydraulics and aeration problems. The available monitoring methods are labor intensive. Microbial fuel cells (MFCs) have emerged as real-time biosensors, including for treatment wetlands (TW) systems. In this study, French VFTW sludge was investigated as inoculum in MFCs, to assessing its adaptation into electrochemical environment as a step for clogging MFC-based biodetector implementation in such systems. The results show that the inoculum was successfully adapted, with stable current generation at 0.4 mA. The electrochemical impedance spectroscopy (EIS) demonstrated the establishment of a biofilm with electroactive characteristics and non-limiting anode. Metagenomic analysis showed that the French VFTW harbor electroactive species, and the MFC created a selective pressure on the VFTW sludge inoculum and significantly shaped the microbial community and function, stimulating the enrichment of electroactive bacteria (EAB), such Geobacterales (4.11% to 5.83%), with potential expression of cytochrome-c for extracellular electron transference (EET). This study illustrates the feasibility of developing electroactive biofilms from French VFTW and suggests its use as an inoculum, improving the integration of TW-MFC systems. Considering these results, the well-adapted anodic biofilm could enable the detection of aeration limitations via cathodic reactions in future studies.
A critical step in developing new biosensing devices is to ensure biofilm adaptability to electrochemical conditions and responsiveness to varying environmental factors. In this study, we investigated the biofilm enrichment from French vertical flow treatment wetland (VFTW) sludge in air-cathode MFCs with varying external resistances (100 and 1000 Ω). Electrochemical Impedance Spectroscopy, Environmental Scanning Electron Microscope, and metagenomic analysis showed that the 100 Ω condition promoted higher current output, lower anode resistance, thicker biofilm formation, and stronger enrichment of the Geobacteraceae. In contrast, 1000 Ω condition resulted lower current output and a reduced abundance of electroactive bacteria. This was aligned with the limited biofilm coverage and pseudocapacitive behavior, which could offer advantages for long-term biosensor operation by controlling electrode fouling and enabling continuous electron transfer. Interestingly, spatial biofilm heterogeneity along the anode depth promoted distinct microbial community compositions. The internal biofilm layers presented an increase in the relative expressions of c-type cytochrome omcB, omcE, omcM, which could potentially regulate its extracellular electron transfer (EET). These findings demonstrate the high adaptability of VFTWs-enriched electroactive biofilms and provide valuable insight for designing strategies to influence biofilm dynamics and stable signal output, fostering the application of MFCs for clogging indication in French VFTWs.