Brice Fernandez

Brice Fernandez

Auto-generated profile, based on publicly available information

Brice Fernandez

GE Healthcare Buc France

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in NeuroImage
Verified
Journal Article
Open access
ACAlexander D. Cohen
Alexander D. Cohen
BYBaolian Yang
Baolian Yang
BFBrice Fernandez
Brice Fernandez
SBSuchandrima Banerjee
Suchandrima Banerjee
YWYang Wang
Yang Wang
Recent advances in functional MRI techniques include multiband (MB) imaging and multi-echo (ME) imaging. In MB imaging multiple slices are acquired simultaneously leading to significant increases in temporal and spatial resolution. Multi-echo imaging enables multiple echoes to be acquired in one shot, where the ME images can be used to denoise the BOLD time series and increase BOLD sensitivity. In this study, resting state fMRI (rs-fMRI) data were collected using a combined MBME sequence and compared to an MB single echo sequence. In total, 29 subjects were imaged, and 18 of them returned within two weeks for repeat imaging. Participants underwent one MBME scan with three echoes and one MB scan with one echo. Both datasets were processed using standard denoising and advanced denoising. Advanced denoising included multi-echo independent component analysis (ME-ICA) for the MBME data and ICA-AROMA for the MB data. Resting state functional connectivity (RSFC) was evaluated using both selective seed-based and whole grey matter (GM) region-of-interest (ROI) based approaches. The reproducibility of connectivity metrics was also analyzed in the repeat subjects. In addition, functional connectivity density (FCD), a data-driven approach that counts the number of significant connections, both within a local cluster and globally, with each voxel was analyzed. Regardless of the standard or advanced denoising technique, all seed-based RSFC was significantly higher for MBME compared to MB. Much more GM ROI combinations showed significantly higher RSFC for MBME vs. MB. Reproducibility, evaluated using the dice coefficient was significantly higher for MBME relative to MB data. Finally, FCD was also higher for MBME vs. MB data. This study showed higher RSFC for MBME vs. MB data using selected seed-based, whole GM ROI-based, and data-driven approaches. Reproducibility found also higher for MBME data. Taken together, these results indicate that MBME is a promising technique for rs-fMRI.

20 September 2017 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
MKMaya Khalifé
Maya Khalifé
BFBrice Fernandez
Brice Fernandez
OJOlivier Jaubert
Olivier Jaubert
MSMichael Soussan
Michael Soussan
VBVincent Brulon
Vincent Brulon
CCClaude Comtat
Claude Comtat
In brain PET/MR applications, accurate attenuation maps are required for accurate PET image quantification. An implemented attenuation correction (AC) method for brain imaging is the single-atlas approach that estimates an AC map from an averaged CT template. As an alternative, we propose to use a zero echo time (ZTE) pulse sequence to segment bone, air and soft tissue. A linear relationship between histogram normalized ZTE intensity and measured CT density in Hounsfield units ( H U ) in bone has been established thanks to a CT-MR database of 16 patients. Continuous AC maps were computed based on the segmented ZTE by setting a fixed linear attenuation coefficient (LAC) to air and soft tissue and by using the linear relationship to generate continuous μ values for the bone. Additionally, for the purpose of comparison, four other AC maps were generated: a ZTE derived AC map with a fixed LAC for the bone, an AC map based on the single-atlas approach as provided by the PET/MR manufacturer, a soft-tissue only AC map and, finally, the CT derived attenuation map used as the gold standard (CTAC). All these AC maps were used with different levels of smoothing for PET image reconstruction with and without time-of-flight (TOF). The subject-specific AC map generated by combining ZTE-based segmentation and linear scaling of the normalized ZTE signal into H U was found to be a good substitute for the measured CTAC map in brain PET/MR when used with a Gaussian smoothing kernel of 4   m m corresponding to the PET scanner intrinsic resolution. As expected TOF reduces AC error regardless of the AC method. The continuous ZTE-AC performed better than the other alternative MR derived AC methods, reducing the quantification error between the MRAC corrected PET image and the reference CTAC corrected PET image.

15 June 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TBTanguy Boucneau
Tanguy Boucneau
BFBrice Fernandez
Brice Fernandez
PLPeder Larson
Peder Larson
LDLuc Darrasse
Luc Darrasse
XMXavier Maître
Xavier Maître
Spirometry is today the gold standard technique for assessing pulmonary ventilatory function in humans. From the shape of a flow-volume loop measured while the patient is performing forced respiratory cycles, the Forced Vital Capacity (FVC) and the Forced Expiratory Volume in one second (FEV1) can be inferred, and the pulmonologist is able to detect and characterize common respiratory afflictions. This technique is non-invasive, simple, widely available, robust, repeatable and reproducible. Yet, its outcomes rely on the patient’s cooperation and provide only global information over the lung. With 3D Magnetic Resonance (MR) Spirometry, local ventilation can be assessed by MRI anywhere in the lung while the patient is freely breathing. The larger dimensionality of 3D MR Spirometry advantageously allows the extraction of original metrics that characterize the anisotropic and hysteretic regional mechanical behavior of the lung. Here, we demonstrated the potential of this technique on a healthy human volunteer breathing along different respiratory patterns during the MR acquisition. These new results are discussed with lung physiology and recent pulmonary CT data. As respiratory mechanics inherently support lung ventilation, 3D MR Spirometry may open a new way to non-invasively explore lung function while providing improved diagnosis of localized pulmonary diseases.

20 November 2019 in European Radiology
Verified
Journal Article
Closed access
PDF file
BSBrian Sgard
Brian Sgard
MKMaya Khalifé
Maya Khalifé
ABArthur Bouchut
Arthur Bouchut
BFBrice Fernandez
Brice Fernandez
MSMarine Soret
Marine Soret
AKAurélie Kas
Aurélie Kas

19 November 2020 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
ACAlexander D. Cohen
Alexander D. Cohen
AJAmritpal S. Jagra
Amritpal S. Jagra
BYBaolian Yang
Baolian Yang
BFBrice Fernandez
Brice Fernandez
SBSuchandrima Banerjee
Suchandrima Banerjee
YWYang Wang
Yang Wang
Background: Blood oxygen level‐dependent (BOLD) functional MRI (fMRI) has been widely applied to detect brain activations. Recent advances in multiband (MB) and multiecho (ME) techniques have greatly improved fMRI methods. MB imaging improves temporal and/or spatial resolution, while ME imaging has been shown to improve BOLD sensitivity. This study aimed to evaluate the novel MBME echo planar imaging (EPI) sequence utilizing MB and ME simultaneously to determine if the MBME outperform the MB single echo (MBSE) sequence for task fMRI.Purpose: To compare the performance of MBME with MBSE in a task fMRI study.Study Type: Prospective.Population: A total of 29 healthy volunteers aged 20–46 years (9 male, 20 female).Field Strength/Sequence: MBSE and MBME gradient‐echo EPI sequences were applied at 3T. Additional T1‐weighted magnetization‐prepared rapid acquisition with gradient echo (MPRAGE) was collected.Assessment: A checkerboard visual task was presented during the functional MBSE and MBME scans. The MBME or MBSE signal was evaluated using the temporal signal‐to‐noise ratio (tSNR). Task activation was evaluated using the z‐score, volume, sensitivity, and specificity. Test–retest metrics of task activation were examined with the Dice coefficient (DC) and intraclass correlation coefficient (ICC) on subjects with repeated scans.Statistical Tests: A linear mixed‐effects model was used to compared MBME and MBSE activation at the voxel base. The paired t‐test was used to compare tSNR, activation z‐score, and volume, along with sensitivity, specificity, and DC between MBSE and MBME.Results: While similar task activation was detected in the visual cortex, MBME showed higher activation volume and higher sensitivity compared with MBSE (P < 0.05). ICC was higher for MBME than MBSE, while there was a trend of differences in DC (P = 0.08).Data Conclusion: MBME resulted in higher task fMRI activation volume and sensitivity without losing specificity. Reliability was also higher for MBME scans compared with MBSE.Level of Evidence: 1Technical Efficacy Stage: 1

1 August 2017 in NeuroImage
Verified
Journal Article
Closed access
BFBrice Fernandez
Brice Fernandez
LLLaura Leuchs
Laura Leuchs
PSPhilipp G. Sämann
Philipp G. Sämann
MCMichael Czisch
Michael Czisch
VSVictor I. Spoormaker
Victor I. Spoormaker