Sofia Velasco

Sofia Velasco

Auto-generated profile, based on publicly available information

Sofia Velasco

Department of Diagnostic Imaging, Fundación Santa Fe de Bogotá, Bogotá, Colombia

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2023 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
TNT.B. Nguyen
T.B. Nguyen
NZN. Zakhari
N. Zakhari
SSS. Velasco Sandoval
S. Velasco Sandoval
AGA. Guarnizo-Capera
A. Guarnizo-Capera
MGM. Alexios Gulak
M. Alexios Gulak
GCG.O. Cron
G.O. Cron
BACKGROUND AND PURPOSE: For patients with high-grade gliomas, the appearance of a new, enhancing lesion after surgery and chemoradiation represents a diagnostic dilemma. We hypothesized that MR perfusion without and with contrast can differentiate tumor recurrence from radiation necrosis. MATERIALS AND METHODS: In this prospective study, we performed 3 MR perfusion methods: arterial spin-labeling, DSC, and dynamic contrast enhancement. For each lesion, we measured CBF from arterial spin-labeling, uncorrected relative CBV, and leakage-corrected relative CBV from DSC imaging. The volume transfer constant and plasma volume were obtained from dynamic contrast-enhanced imaging without and with T1 mapping using modified Look-Locker inversion recovery (MOLLI). The diagnosis of tumor recurrence or radiation necrosis was determined by either histopathology for patients who underwent re-resection or radiologic follow-up for patients who did not have re-resection. RESULTS: There were 26 patients with 32 lesions, 19 lesions with tumor recurrence and 13 lesions with radiation necrosis. Compared with radiation necrosis, lesions with tumor recurrence had higher CBF (P = .033), leakage-corrected relative CBV (P = .048), and plasma volume using MOLLI T1 mapping (P = .012). For differentiating tumor recurrence from radiation necrosis, the areas under the curve were 0.81 for CBF, 0.80 for plasma volume using MOLLI T1 mapping, and 0.71 for leakage-corrected relative CBV. A correlation was found between CBF and leakage-corrected relative CBV (rs = 0.54), volume transfer constant, and plasma volume (0.50 < rs< 0.77) but not with uncorrected relative CBV (rs = 0.20, P = .29). CONCLUSIONS: In the differentiation of tumor recurrence from radiation necrosis in a newly enhancing lesion, the diagnostic value of arterial spin-labeling–derived CBF is similar to that of DSC and dynamic contrast-enhancement–derived blood volume.

1 July 2014 in Revista Colombiana de Cancerología
Verified
Journal Article
Closed access
SVSofia Velasco
Sofia Velasco
OBOscar Bernal
Oscar Bernal
ASAntonio Salazar
Antonio Salazar
JRJavier Romero
Javier Romero
ÁMÁngela Moreno
Ángela Moreno
XDXavier Díaz
Xavier Díaz

1 November 2016 in Journal of the American College of Radiology
Verified
Journal Article
Open access
PDF file
ASAntonio J. Salazar
Antonio J. Salazar
JRJavier A. Romero
Javier A. Romero
OBOscar A. Bernal
Oscar A. Bernal
AMAngela P. Moreno
Angela P. Moreno
SVSofía C. Velasco
Sofía C. Velasco
Variability in radiologists’ interpretations may reduce the accuracy of mammography in the early detection of breast cancer [ 1 x 1 Elmore, J.G., Wells, C.K., Lee, C.H., Howard, D.H., and Feinstein, A.R. Variability in radiologists’ interpretations of mammograms. N Engl J Med. 1994; 331: 1493–1499 Crossref | PubMed | Scopus (463) | Google Scholar See all References ] [1] . To standardize the reporting of findings in different imaging modalities, the ACR developed the BI-RADS® atlas [ 2 x 2 Sickles, E.A., D’Orsi, C.J., and Bassett, L.W. ACR BI-RADS® mammography. American College of Radiology, Reston, Virginia; 2013 Google Scholar See all References ] [2] . Several studies have evaluated the accuracy of this system compared with traditional mammography [ 3 x 3 Berg, W.A., Campassi, C., Langenberg, P., and Sexton, M.J. Breast Imaging Reporting and Data System: inter- and intraobserver variability in feature analysis and final assessment. AJR Am J Roentgenol. 2000; 174: 1769–1777 Crossref | PubMed | Scopus (310) | Google Scholar See all References , 4 x 4 McKay, C., Hart, C., and Erbacher, G. Objectivity and accuracy of mammogram interpretation using the BI-RADS final assessment categories in 40- to 49-year-old women. J Am Osteopath Assoc. 2000; 100: 615–620 PubMed | Google Scholar See all References ]. Other studies have evaluated the accuracy of mammography, ultrasound, and physical examination, compared with biopsy findings, when using the BI-RADS lexicon [ 5 x 5 Lorenzen, J., Wedel, A.K., Lisboa, B.W., Löning, T., and Adam, G. Diagnostic mammography and sonography: concordance of the breast imaging reporting assessments and final clinical outcome. Fortschr Röntgenstr. 2005; 177: 1545–1551 Crossref | Scopus (13) | Google Scholar See all References , 6 x 6 Kolb, T.M., Lichy, J., and Newhouse, J.H. Comparison of the performance of screening mammography, physical examination, and breast US and evaluation of factors that influence them: an analysis of 27,825 patient evaluations. Radiology. 2002; 225: 165–175 Crossref | PubMed | Scopus (1026) | Google Scholar See all References ].

29 September 2016 in International Journal of Telemedicine and Applications
Verified
Journal Article
Open access
PDF file
ASAntonio J. Salazar
Antonio J. Salazar
JRJavier A. Romero
Javier A. Romero
OBOscar A. Bernal
Oscar A. Bernal
AMAngela P. Moreno
Angela P. Moreno
SVSofía C. Velasco
Sofía C. Velasco
XDXavier A. Díaz
Xavier A. Díaz
Objective.The aim of this study was to evaluate and compare the clinical performance of different alternatives to implement low-cost screening telemammography. We compared computed radiography, film printed images, and digitized films produced with a specialized film digitizer and a digital camera.Material and Methods.The ethics committee of our institution approved this study. We assessed the equivalence of the clinical performance of observers for cancer detection. The factorial design included 70 screening patients, four technological alternatives, and cases interpreted by seven radiologists, for a total of 1,960 observations. The variables evaluated were the positive predictive value (PPV), accuracy, sensitivity, specificity, and the area under the receiver operating characteristic curves (AUC).Result. The mean values for the observed variables were as follows: accuracy ranged from 0.77 to 0.82, the PPV ranged from 0.67 to 0.68, sensitivity ranged from 0.64 to 0.74, specificity ranged from 0.87 to 0.90, and the AUC ranged from 0.87 to 0.90. At a difference of 0.1 to claim equivalence, all alternatives were equivalent for all variables.Conclusion.Our findings suggest that telemammography screening programs may be provided to underserved populations at a low cost, using a film digitizer or a digital camera.

7 May 2014 in Journal of Digital Imaging
Verified
Journal Article
Open access
PDF file
ASAntonio J. Salazar
Antonio J. Salazar
JRJavier Romero
Javier Romero
OBOscar Bernal
Oscar Bernal
AMAngela Moreno
Angela Moreno
SVSofía Velasco
Sofía Velasco
XDXavier Díaz
Xavier Díaz
The aim of this study was to evaluate the diagnostic accuracy for detecting breast cancer using different telemammography configurations, including combinations of both low-cost capture devices and consumer-grade color displays. At the same time, we compared each of these configurations to film-screen readings. This study used a treatment-by-reader-by-case factorial design. The sample included 70 mammograms with 34 malignant cases. The readers consisted of four radiologists who classified all of the cases according to the categories defined by the Breast Imaging Reporting and Data System (BI-RADS). The evaluated capture devices included a specialized film digitizer and a digital camera, and the evaluated displays included liquid crystal display (LCD) and light-emitting diode (LED) consumer-grade color displays. Receiver operating characteristic curves, diagnostic accuracy (measured as the area under these curves), accuracy of the composition classification, sensitivity, specificity, and the degree of agreement between readers in the detection of malignant cases were also evaluated. Comparisons of diagnostic accuracy between film-screen and the different combinations of digital configurations showed no significant differences for nodules, calcifications, and asymmetries. In addition, no differences were observed in terms of sensibility or specificity when the degree of malignancy using the film-screen method was compared to that provided with digital configurations. Similar results were observed for the classification of breast composition. Furthermore, all observed reader agreements of malignant detection between film-screen and digital configurations were substantial. These findings indicate that the evaluated digital devices showed comparable diagnostic accuracy to the reference treatment (film-screen).

19 November 2013
Verified
Conference Paper
Closed access
PDF file
ASAntonio J. Salazar
Antonio J. Salazar
JRJavier Romero
Javier Romero
OBOscar Bernal
Oscar Bernal
AMAngela Moreno
Angela Moreno
SVSofía Velasco
Sofía Velasco
XDXavier Díaz
Xavier Díaz
The aim of this study was to compare the diagnostic accuracy of the consumer-grade and medical-grade monitors —with very different costs— in breast cancer detection, when using with and without Digital Imaging and Communication in Medicine (DICOM) standard calibration. This was a retrospective study with factorial design and repeated measures, using 70 digital mammograms (40 benign or normal cases and 30 malignant cases), four radiologists, and three displays, with and without display calibration. Film mammograms were also included. Readings were classified according to the Breast Imaging Reporting and Data System. One medical-grade grayscale display and two consumer-grade displays were compared. Receiver operating characteristics curves were plotted for nodules, micro calcifications and the degree of malignancy. The diagnostic accuracy for each device was calculated as the area under these curves and accuracies were compared using analysis of variance.