Beldan Polat

Beldan Polat

Auto-generated profile, based on publicly available information

Beldan Polat

Istanbul Faculty of Medicine, Department of Otorhinolaryngology, Istanbul University, Istanbul, Turkey

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2019 in Turkish Archives of Otorhinolaryngology
Verified
Journal Article
Open access
CDCan Doruk
Can Doruk
MÇMehmet Çelik
Mehmet Çelik
HKHakan Kara
Hakan Kara
BPBeldan Polat
Beldan Polat
YGYahya Guldiken
Yahya Guldiken
KOKadir Serkan Orhan
Kadir Serkan Orhan
Türk Otorinolarengoloji Arşivi

3 September 2019 in The Journal of International Advanced Otology
Verified
Journal Article
Open access
KOKadir Serkan Orhan
Kadir Serkan Orhan
BPBeldan Polat
Beldan Polat
MÇMehmet Çelik
Mehmet Çelik
ŞÇŞenol Çomoğlu
Şenol Çomoğlu
YGYahya Güldiken
Yahya Güldiken
The aim of the present study was to describe the use of the endoscopic-assisted cochlear implantation in cases with an unsuccessful standard surgical technique because of not achieving adequate exposure to the round window (RW). Three patients with a bilateral profound hearing loss were operated using an endoscopic-assisted cochlear implant procedure at our tertiary university referral center between 2012 and 2014. In all of the patients, a retroauricular “c” shaped incision was performed and a subperiosteal pocket was created. Standard cortical mastoidectomy and posterior tympanotomy were accomplished using a otomicroscope. However, RW and promontory could not be seen using this approach. The tympanomeatal flap was elevated and the middle ear cavity was entered A rigid 0 degree endoscope (2.7 mm wide, 18 cm in length) (Karl Storz company, Tuttlingen, Germany) and a connected HD camera system (Karl Storz Company, Tuttlingen, Germany) were used to expose RW through posterior tympanotomy, and a drill was passed through the external ear canal. The RW niche was removed using a diamond burr under endoscopic view; the endoscope was placed through the external ear canal, and electrodes were transferred through posterior tympanotomy. The electrodes were fully inserted under the endoscopic view in all cases. Endoscopic-assisted cochlear implantation may be a safe alternative surgical technique in cases where surgeons are not able to visualize RW and promontory using a microscope.

3 September 2019 in The Journal of International Advanced Otology
Verified
Journal Article
Open access
MÇMehmet Çelik
Mehmet Çelik
KOKadir Serkan Orhan
Kadir Serkan Orhan
EÖErkan Öztürk
Erkan Öztürk
HAHakan Avcı
Hakan Avcı
BPBeldan Polat
Beldan Polat
YGYahya Güldiken
Yahya Güldiken
OBJECTIVES: To determine the benefit of a routine plain radiography (X-ray) for confirming the optimal electrode position in cochlear implant surgery. MATERIALS and METHODS: In total, 245 patients (135 males and 111 females) who underwent cochlear implantation in a single tertiary referral center were included in this study. Postoperative plain X-ray findings and electrophysiological tests were retrospectively analyzed. RESULTS: The mean age was 11.4±14.6 years (range, 1–70 years). Overall, 196 (80%) patients were pediatric patients (age,

16 December 2019 in The Journal of International Advanced Otology
Verified
Journal Article
Open access
KOKadir Serkan Orhan
Kadir Serkan Orhan
MÇMehmet Çelik
Mehmet Çelik
BPBeldan Polat
Beldan Polat
LALevent Aydemir
Levent Aydemir
AAAydın Aydoseli
Aydın Aydoseli
YGYahya Güldiken
Yahya Güldiken
OBJECTIVES: Petrous bone cholesteatoma is a rare pathologic entity and may be a difficult surgical challenge because of potential involvement of the facial nerve, carotid artery, dura mater, otic capsule and superior petrosal or lateral sinus. The objective of this article is to present the endoscope-assisted surgery for petrous bone cholesteatoma. MATERIALS and METHODS: Eight patients (nine ears) who underwent endoscope-assisted petrous bone surgery for cholesteatoma. Pure tone audiogram, magnetic resonance imaging were performed at preoperatively, and at approximately 12 months postoperatively. RESULTS: Endoscope assisted surgery was performed in 8 patients and 9 ears. Of these patients, 6 were male and 2 were females. Median age was 19,5 (range 7-52) years. Hearing was able to preserved in 8 ears (8/9). Recurrence disease was observed one ear in long term follow up (1/9). In another one patient, cholesteatoma pearl was removed in the office. CONCLUSION: Endoscope-assisted surgery can allow removal of cholesteatoma of petrous apex with preserving hearing. It also provides to remove the cholesteatoma via transmastoid approach for perilabyrinthine space as “minimally invasive surgery” instead of middle fossa approach that is standard surgical procedure. In apical and peri-labyrinthine cholesteatomas, endoscopes allow to preserve hearing with middle fossa approach instead of trans-otic/ trans-labyrinthine/trans-cochlear approach. Cite this article as: Orhan KS, Çelik M, Polat B, Aydemir L, Aydoseli A, Sencer A, et al. Endoscope-Assisted Surgery for Petrous Bone Cholesteatoma with Hearing Preservation. J Int Adv Otol 2019; 15(3): 391-5.

1 January 2021 in The Journal of International Advanced Otology
Verified
Journal Article
Open access
KOKadir Serkan Orhan
Kadir Serkan Orhan
MÇMehmet Çelik
Mehmet Çelik
BPBeldan Polat
Beldan Polat
TDTuğçe Dikici
Tuğçe Dikici
YGYahya Güldiken
Yahya Güldiken
OBJECTIVES: Wideband tympanometry (WBT) measurements show sensitivity to trends in external ear canal/middle ear maturation and changes in middle ear status as a result of different types of dysfunction. This study aims to determine the effects of cochlear implantation (CI) on middle ear status. MATERIALS and METHODS: This is a prospective comparative clinical study that has been done in a tertiary referral center. The patients who underwent unilateral cochlear implantation were included in the study. All the participants were under 18 years of age and had congenital bilateral profound sensorineural hearing loss (SNHL). WBT measurements of implanted ears were calculated and compared to those of non-implanted ears (control group) in the same patient group. The differences in these measurements were subjected to statistical analyses. RESULTS: A total of 48 patients (96 ears) who underwent unilateral CI were included in the study. Our study revealed that significant reductions in the average absorbance ratios occurred at all measured frequencies and that the average resonance frequency increased more significantly in the implanted ears compared with those of control group (p<0.001). The difference in the average peak pressure was not significant among two groups. (p=0.211) CONCLUSION: This study shows that the average absorbance ratio decreases and average resonance frequency increases after cochlear implantation. These findings may be related to increased stiffness in middle and inner ear system. Future studies are needed for more detailed information and recommendations on this topic. Cite this article as: Orhan KS, Çelik M, Polat B, Dikici T, Güldiken Y. Wideband Absorbance Outcomes of Cochlear Implantation: A Comparative Clinical Study. J Int Adv Otol 2021; 17(1): 9-12.

10 July 2023 in American Journal of Otolaryngology
Verified
Journal Article
Closed access
KOKadir Serkan Orhan
Kadir Serkan Orhan
SSSaid Sönmez
Said Sönmez
HKHakan Kara
Hakan Kara
KAKagan Avcı
Kagan Avcı
BPBeldan Polat
Beldan Polat
YGYahya Güldiken
Yahya Güldiken