Artificial lighting accounts for a substantial share of electricity use in indoor farming. At constant photosynthetic photon flux density (PPFD), shortening the photoperiod reduces both daily light integral (DLI) and lighting electricity consumption. However, most lettuce studies have investigated comparatively large DLI differences, leaving marginal reductions poorly characterized. This study tested whether a 30-min reduction in photoperiod could lower lighting electricity use without compromising crop performance. Red oak leaf lettuce (Lactuca sativa L. ‘Saturdai RZ’) was grown at 163 µmol m⁻² s⁻¹ PPFD under 15.0 h (Control) and 14.5 h (DLIreduced), corresponding to 8.80 and 8.51 mol m⁻² d⁻¹. The 3.33% DLI reduction did not significantly affect final shoot fresh or dry weight, dry matter content, leaf area, leaf number, chlorophyll a or b, effective quantum yield of photosystem II, apparent electron transport rate, total phenolic acids, or the quantified flavonoid. Caffeoylmalic acid increased by approximately 36%, while the overall phenolic acid pool remained unchanged. Incident light-use efficiency and lighting energy-use efficiency were also unaffected. LED electricity consumption decreased by 3.33%, equivalent to 316.79 MWh ha⁻¹ yr⁻¹ and approximately €50,686 ha⁻¹ yr⁻¹ for one cultivation layer at €0.16 kWh⁻¹. In a theoretical five-layer system, annual savings reached 1,583.94 MWh and €253,431 per hectare of ground footprint. Break-even analysis indicated that a hypothetical fresh-weight reduction of 5.9-14.7%, depending on product value, could be tolerated before the electricity-cost advantage was eliminated. Marginal DLI reduction therefore provided energy and economic savings without detectable losses in crop performance under the tested conditions.