Suktipol Kiatthaveephong

Suktipol Kiatthaveephong

Auto-generated profile, based on publicly available information

Suktipol Kiatthaveephong

Bio-Inspired Robotics and Neural Engineering (BRAIN) Laboratory, School of Information Science and Technology (IST), Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong, Thailand

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
PAPhairot Autthasan
Phairot Autthasan
RCRattanaphon Chaisaen
Rattanaphon Chaisaen
TSThapanun Sudhawiyangkul
Thapanun Sudhawiyangkul
PRPhurin Rangpong
Phurin Rangpong
SKSuktipol Kiatthaveephong
Suktipol Kiatthaveephong
TWTheerawit Wilaiprasitporn
Theerawit Wilaiprasitporn
Objective: Advances in the motor imagery (MI)-based brain-computer interfaces (BCIs) allow control of several applications by decoding neurophysiological phenomena, which are usually recorded by electroencephalography (EEG) using a non-invasive technique. Despite significant advances in MI-based BCI, EEG rhythms are specific to a subject and various changes over time. These issues point to significant challenges to enhance the classification performance, especially in a subject-independent manner. Methods: To overcome these challenges, we propose MIN2Net, a novel end-to-end multi-task learning to tackle this task. We integrate deep metric learning into a multi-task autoencoder to learn a compact and discriminative latent representation from EEG and perform classification simultaneously. Results: This approach reduces the complexity in pre-processing, results in significant performance improvement on EEG classification. Experimental results in a subject-independent manner show that MIN2Net outperforms the state-of-the-art techniques, achieving an F1-score improvement of 6.72% and 2.23% on the SMR-BCI and OpenBMI datasets, respectively. Conclusion: We demonstrate that MIN2Net improves discriminative information in the latent representation. Significance: This study indicates the possibility and practicality of using this model to develop MI-based BCI applications for new users without calibration.

14 October 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SKSupavit Kongwudhikunakorn
Supavit Kongwudhikunakorn
SKSuktipol Kiatthaveephong
Suktipol Kiatthaveephong
KTKamonwan Thanontip
Kamonwan Thanontip
PLPitshaporn Leelaarporn
Pitshaporn Leelaarporn
MPMaytus Piriyajitakonkij
Maytus Piriyajitakonkij
TWTheerawit Wilaiprasitporn
Theerawit Wilaiprasitporn
In the status quo, dementia (DEM) is yet to be cured. Precise diagnosis prior to the onset of the symptoms can prevent the rapid progression of the emerging cognitive impairment. Recent progress has shown that electroencephalography (EEG) is the promising and cost-effective test to facilitate the detection of neurocognitive disorders. However, most of the existing works have been using only resting-state EEG. The efficiencies of EEG signals from various cognitive tasks, for DEM classification, have yet to be thoroughly investigated. In this study, we designed four cognitive tasks that engage different cognitive performances: attention, working memory, and executive function. We investigated these tasks by using statistical analysis on both time and frequency domains of EEG signals from three classes of human subjects: DEM, mild cognitive impairment (MCI), and normal control (NC). We also further evaluated the classification performances of two features extraction methods: principal component analysis (PCA) and filter bank common spatial pattern (FBCSP). We found that the working memory-related tasks yielded good performances for DEM recognition in both cases using PCA and FBCSP. Moreover, FBCSP with features combination from four tasks revealed the best sensitivity of 0.87 and the specificity of 0.80. To our best knowledge, this is the first work that concurrently investigated several cognitive tasks for DEM recognition using both statistical analysis and classification scores. Our results yielded essential information to design and aid in conducting further experimental tasks to early diagnose DEM patients.

11 November 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
PCPhuridet Cherachapridi
Phuridet Cherachapridi
PWPatcharapol Wachiraphan
Patcharapol Wachiraphan
PRPhurin Rangpong
Phurin Rangpong
SKSuktipol Kiatthaveephong
Suktipol Kiatthaveephong
SKSupavit Kongwudhikunakorn
Supavit Kongwudhikunakorn
TSThapanun Sudhawiyangkul
Thapanun Sudhawiyangkul
Detection of mild cognitive impairment (MCI) and dementia (DEM) is an important topic because, unless it is treated early, MCI can progress to DEM, which is an untreatable disease. This paper proposes a timed-up-and-go (TUG) task features analysis and classification of MCI and DEM using inertial measurement units (IMU) in wearable devices. Our goal is to create a generalized model that can be used for pre-clinical screening. As a result, rather than classifying only one subtype of dementia, such as Alzheimer’s disease (AD) or Parkinson’s disease (PD), we classify all subtypes as DEM. We also utilize feature selection methods on features from TUG tasks to optimize the MCI and DEM classification performance. From the results, our generalized model can outperform other works in NC-MCI&DEM classification with accuracy of 86.94% and sensitivity of 97.40%. For NC-DEM classification, the performance of our generalized model is slightly lower than that of specific-subtype models (e.g., NC vs. AD). However, our generalized model can outperform the specific-subtype models when using with a diverse variety of subtypes. It is a reasonable trade-off, and it can be a good first step toward a future where the patient can pre-clinically self-screening the cognitive impairments using wearable devices in free-living environments. This could allow patients to notice the cognitive impairment early on and seek a comprehensive diagnosis from a doctor.

30 July 2025 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
SKSupavit Kongwudhikunakorn
Supavit Kongwudhikunakorn
WPWuttikorn Ponwitayarat
Wuttikorn Ponwitayarat
SKSuktipol Kiatthaveephong
Suktipol Kiatthaveephong
WPWipamas Polpakdee
Wipamas Polpakdee
TYTohru Yagi
Tohru Yagi
TWTheerawit Wilaiprasitporn
Theerawit Wilaiprasitporn
High mental workload poses significant challenges across various domains, often impairing performance and decision-making. Recent advancements in Internet of Things (IoT) technologies have enabled continuous monitoring of brain activity via electroencephalography (EEG), facilitating real-time assessment of mental workload during task execution. Early detection of elevated workload levels is essential for mitigating potential adverse outcomes. This paper presents EEGMeNet, an end-to-end, multi-task neural network designed to classify mental workload levels from EEG signals. EEGMeNet consists of four key components: (1) a local feature learner that extracts spectral and spatial characteristics, (2) a global feature learner employing attention-based mechanisms to model temporal dependencies, (3) a feature preserver that enhances representation learning, and (4) a supervised classifier for mental workload classification. The proposed model is evaluated across five mental task EEG datasets—including one acquired in clinical settings—under both within-subject and cross-subject, as well as within-session and cross-session classification paradigms. EEGMeNet outperforms nine state-of-the-art baselines, achieving an accuracy of 87.49±2.66% and an F1 score of 85.26±2.63% in cross-subject evaluations, showing at least a 9% improvement in accuracy and a 12% gain in F1 score. Moreover, EEGMeNet demonstrates low prediction time complexity, making it well-suited for deployment on resource-constrained IoT devices. These results underscore EEGMeNet’s robustness to inter-subject and multi-session EEG variability, validating its effectiveness for real-world EEG-IoT applications. This work establishes EEGMeNet as a promising foundation for future mental workload classification research in EEG-IoT environments.

21 January 2026 in GigaScience
Verified
Journal Article
Open access
BUBenjakarn Uengsawapak
Benjakarn Uengsawapak
SKSupavit Kongwudhikunakorn
Supavit Kongwudhikunakorn
SKSuktipol Kiatthaveephong
Suktipol Kiatthaveephong
WPWipamas Polpakdee
Wipamas Polpakdee
RCRattanaphon Chaisaen
Rattanaphon Chaisaen
TWTheerawit Wilaiprasitporn
Theerawit Wilaiprasitporn
This study presents the first publicly accessible electroencephalography (EEG) dataset explicitly targeting sit-to-stand and stand-to-sit transitions during both motor execution (ME) and motor imagery (MI) tasks. Twenty-two healthy participants performed sitting and standing transitions under well-controlled experimental conditions while 60-channel EEG, electrooculography (EOG), and electromyography (EMG) signals were synchronously recorded. The dataset enables the exploration of neural activation patterns associated with lower-limb movements and supports the development of EEG-based brain–computer interface (BCI) algorithms for mobility assistance and rehabilitation. To validate the dataset, benchmark classification was conducted on three baseline deep learning methods—CTNet, EEGNet, and TCANet. Given the high inter-subject variability inherent to EEG, leave-one-subject-out cross-validation is used to ensure no subject bias during evaluation. Results demonstrated consistent decoding performance with mean accuracies of approximately 81% for ME and 73% for MI, indicating the reliability and usability of the dataset. Additionally, analyses of movement-related cortical potentials (MRCPs) and event-related desynchronization/synchronization (ERD/ERS) patterns revealed distinct neural signatures across the transition phases. This dataset provides a comprehensive foundation for studying lower-limb motor control, neural dynamics, and the advancement of MI-based BCIs for rehabilitation and assistive technologies.