Cesca Miller

Cesca Miller

Auto-generated profile, based on publicly available information

Cesca Miller

Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720-8136, United States of America

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2024 in Energy
Verified
Journal Article
Open access
WGWill Gorman
Will Gorman
GBGalen Barbose
Galen Barbose
CMCesca Miller
Cesca Miller
PWPhilip White
Philip White
JCJuan Pablo Carvallo
Juan Pablo Carvallo
SBSunhee Baik
Sunhee Baik

27 November 2024 in Environmental Research: Energy
Verified
Journal Article
Open access
SBSunhee Baik
Sunhee Baik
CMCesca Miller
Cesca Miller
JCJuan Pablo Carvallo
Juan Pablo Carvallo
Behind the meter rooftop solar plus storage (PVESS) has the potential to benefit the hosting customers by providing affordability, environmental, and reliability and resilience value. Whereas the bill reduction and environmental benefits of PVESS are well studied, its monetary resilience benefits are less understood. The increasing trend of power interruptions driven by extreme weather events heightens the need to understand these benefits. This study leverages various publicly available datasets to perform a cost benefit analysis of adding to determine the resilience value of PVESS for a typical single family home in each county in the continental U.S. We find that PVESS is very effective to technically mitigate interruptions across the country. However, the monetary benefits in the base case only cover about 14% of battery costs, with no county exceeding 60%. This is somewhat expected, given that PVESS provide other monetary benefits that are not part of this analysis. Through sensitivities, we find that higher frequency of extreme weather events roughly triples the resilience value of PVESS and that higher values of lost load double the same metric. Our sensitivity analysis shows that the benefit cost ratio of PVESS for customers living in areas with higher-than-average frequency of long duration interruptions and value of lost load is already above one even without considering other value streams. We conclude with recommendations that regulators and utilities could implement to enable customers to calculate and capture the resilience value of PVESS more efficiently.

15 October 2024
Verified
Report
Closed access
WGWill Gorman
Will Gorman
GBGalen Barbose
Galen Barbose
SBSunhee Baik
Sunhee Baik
CMCesca Miller
Cesca Miller
JCJuan Carvallo
Juan Carvallo

5 February 2022 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
SFSydney Forrester
Sydney Forrester
GBGalen Barbose
Galen Barbose
CMChandler Miller
Chandler Miller
SASneak Peek Administrator
Sneak Peek Administrator
CMCesca Miller
Cesca Miller
Compensation structures for residential solar photovoltaic systems are evolving toward a model that incentivizes the use of battery storage to maximize solar self-consumption. Relying on a unique dataset of metered consumption data from residential customers across six U.S. utilities, we show that batteries operated solely in this manner provide virtually no value to the bulk power system. This represents a large lost opportunity relative to the annual value of 16–33 USD per kWh of storage capacity if operated instead to maximize its energy and capacity value. That value gap is projected to persist at higher renewable energy penetrations, but could be reduced by 50-80% without significantly degrading solar self-consumption if utilities allow and incentivize battery discharge to the grid during the highest marginal-cost hours. In this way, solar self-consumption can be combined with more beneficial storage applications, even if it provides little grid value on its own.