7 September 2007 in Atmospheric Chemistry and Physics
In this study vapour pressure osmometry was used to determine water activity in the solutions of organic acids. The surface tension of the solutions was also monitored in parallel and then Köhler curves were calculated for nine organic acids (oxalic, malonic, succinic, glutaric, adipic, maleic, malic, citric and cis-pinonic). Surface tension depression is negligible for most of the organic acids in dilute (≤1 w/w%) solutions. Therefore, these compounds affect equilibrium vapour pressure only in the beginning phase of droplet formation when the droplet solution is more concentrated but not necessarily at the critical size. An exception is cis-pinonic acid which remarkably depress surface tension also in dilute (0.1 w/w%) solution and hence at the critical point. The surface tension of organic acid solutions is influenced by the solubility of the compound, the length of the carbon chain and also by the polar functional groups present in the molecule. Similarly to surface tension solubility plays an important role also in water activity: compounds with higher solubility (e.g. malonic, maleic and glutaric acid) reduce water activity significantly in the early phase of droplet formation while less soluble acids (e.g. succinic and adipic acid) are saturated in small droplets and the solution starts diluting only in bigger droplets. As a consequence, compounds with lower solubility have a minor effect on water activity in the early phase of droplet formation. To deduce the total effect Köhler curves were calculated and critical supersaturations (Sc) were determined for the organic acids using measured surface tension and water activity. It was found that critical supersaturation grew with growing carbon number. Oxalic acid had the lowest critical supersaturation in the size range studied and it was comparable to the activation of ammonium sulphate. The Sc values obtained in this study were compared to data from CCNC experiments. In most cases good agreement was found. For modelling purposes Sc vs. ddry plots are given and the dependence of water activity and surface tension on concentration are also formulated.
13 July 2017 in Atmospheric Measurement Techniques
Beta-attenuation monitors are used worldwide to monitor PM mass concentration with high temporal resolution. Hourly PM10 and PM2. 5 dry mass concentrations are publicly available with the tacit assumption that water is effectively removed prior to the measurement. However, as both the filter material of the monitor and the aerosol particles are capable of retaining a significant amount of water even at low relative humidities, the basic assumption may not be valid, resulting in significant bias in reported PM10 and PM2. 5 concentrations. Here we show that in PM10 measurement, particle-free air can produce apparent hourly average PM concentrations in the range of −13–+21 µg m−3 under conditions of fluctuating relative humidity. Positive and negative apparent readings are observed with increasing and decreasing relative humidities, respectively. Similar phenomena have been observed when the instrument filter was previously loaded with atmospheric aerosol. As a result the potential measurement biases in hourly readings arising from the interaction with water may be in the range of −53… + 69 %.
1 September 2021 in Atmospheric Environment
19 April 2007 in EGUsphere
In this study vapour pressure osmometry was used to determine water activity in the solutions of organic acids. The surface tension of the solutions was also monitored in parallel and then Köhler curves were calculated for nine organic acids (oxalic, malonic, succinic, glutaric, adipic, maleic, malic, citric and cis-pinonic). Surface tension depression is negligible for most of the organic acids in dilute (≤1 w/w%) solutions. Therefore, these compounds affect equilibrium vapour pressure only in the beginning phase of droplet formation when the droplet solution is more concentrated but not necessarily at the critical size. An exception is cis-pinonic acid which remarkably depress surface tension also in dilute (0.1 w/w%) solution and hence at the critical point. The surface tension of organic acid solutions is influenced by the solubility of the compound, the length of the carbon chain and also by the polar functional groups present in the molecule. Similarly to surface tension solubility plays an important role also in water activity: compounds with higher solubility (e.g. malonic, maleic and glutaric acid) reduce water activity significantly in the early phase of droplet formation while less soluble acids (e.g. succinic and adipic acid) are saturated in small droplets and the solution starts diluting only in bigger droplets. As a consequence, compounds with lower solubility have a minor effect on water activity in the early phase of droplet formation. To deduce the total effect Köhler curves were calculated and critical supersaturations (Sc) were determined for the organic acids using measured surface tension and water activity. It was found that critical supersaturation grew with growing carbon number. Oxalic acid had the lowest critical supersaturation in the size range studied and it was comparable to the activation of ammonium sulphate. The Sc values obtained in this study were compared to data from CCNC experiments. In most cases good agreement was found. For modelling purposes Sc vs. ddry plots are given and the dependence of water activity and surface tension on concentration are also formulated.
6 March 2017 in EGUsphere
Beta attenuation monitors are used worldwide to monitor PM concentration with high temporal resolution. Hourly PM10 and PM2.5 dry mass concentrations are publicly available with the tacit assumption that water is effectively removed prior to the measurement. However, as both the filter material of the monitor and the aerosol particles are capable of retaining significant amount of water even at low relative humidities, the basic assumption may not be valid resulting in significant bias in reported PM10 and PM2.5 concentrations. Here we show that in PM10 measurement particle-free air can produce apparent hourly average PM concentrations in the range of −13–+21 µg m−3 under conditions of fluctuating relative humidity. Positive and negative apparent readings are observed with increasing and decreasing relative humidities, respectively. Similar phenomena have been observed when the instrument filter was previously loaded with atmospheric aerosol. As a result, the potential measurement biases in hourly readings arising from the interaction with water may be in the range of −53 %–+69 %.