Che Wang

Che Wang

Auto-generated profile, based on publicly available information

Che Wang

State Key Laboratory of Robotics and Systems, Harbin Institute of Technology, Harbin 150080, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2022 in Science Robotics
Verified
Journal Article
Closed access
CHChong Hong
Chong Hong
ZRZiyu Ren
Ziyu Ren
CWChe Wang
Che Wang
MLMingtong Li
Mingtong Li
YWYingdan Wu
Yingdan Wu
MSMetin Sitti
Metin Sitti
The limited force or torque outputs of miniature magnetic actuators constrain the locomotion performances and functionalities of magnetic millimeter-scale robots. Here, we present a magnetically actuated gearbox with a maximum size of 3 millimeters for driving wireless millirobots. The gearbox is assembled using microgears that have reference diameters down to 270 micrometers and are made of aluminum-filled epoxy resins through casting. With a magnetic disk attached to the input shaft, the gearbox can be driven by a rotating external magnetic field, which is not more than 6.8 millitesla, to produce torque of up to 0.182 millinewton meters at 40 hertz. The corresponding torque and power densities are 12.15 micronewton meters per cubic millimeter and 8.93 microwatt per cubic millimeter, respectively. The transmission efficiency of the gearbox in the air is between 25.1 and 29.2% at actuation frequencies ranging from 1 to 40 hertz, and it lowers when the gearbox is actuated in viscous liquids. This miniature gearbox can be accessed wirelessly and integrated with various functional modules to repeatedly generate large actuation forces, strains, and speeds; store energy in elastic components; and lock up mechanical linkages. These characteristics enable us to achieve a peristaltic robot that can crawl on a flat substrate or inside a tube, a jumping robot with a tunable jumping height, a clamping robot that can sample solid objects by grasping, a needle-puncture robot that can take samples from the inside of the target, and a syringe robot that can collect or release liquids.

13 March 2024 in Science Robotics
Verified
Journal Article
Closed access
CHChong Hong
Chong Hong
YWYingdan Wu
Yingdan Wu
CWChe Wang
Che Wang
ZRZiyu Ren
Ziyu Ren
CWChunxiang Wang
Chunxiang Wang
MSMetin Sitti
Metin Sitti
Wireless millimeter-scale robots capable of navigating through fluid-flowing tubular structures hold substantial potential for inspection, maintenance, or repair use in nuclear, industrial, and medical applications. However, prevalent reliance on external powering constrains these robots’ operational range and applicable environments. Alternatives with onboard powering must trade off size, functionality, and operation duration. Here, we propose a wireless millimeter-scale wheeled robot capable of using environmental flows to power and actuate its long-distance locomotion through complex pipelines. The flow-powering module can convert flow energy into mechanical energy, achieving an impeller speed of up to 9595 revolutions per minute, accompanied by an output power density of 11.7 watts per cubic meter and an efficiency of 33.7%. A miniature gearbox module can further transmit the converted mechanical energy into the robot’s locomotion system, allowing the robot to move against water flow at an average rate of up to 1.05 meters per second. The robot’s motion status (moving against/with flow or pausing) can be switched using an external magnetic field or an onboard mechanical regulator, contingent on different proposed control designs. In addition, we designed kirigami-based soft wheels for adaptive locomotion. The robot can move against flows of various substances within pipes featuring complex geometries and diverse materials. Solely powered by flow, the robot can transport cylindrical payloads with a diameter of up to 55% of the pipe’s diameter and carry devices such as an endoscopic camera for pipeline inspection, a wireless temperature sensor for environmental temperature monitoring, and a leak-stopper shell for infrastructure maintenance.

14 January 2026 in Nature
Verified
Journal Article
Open access
PDF file
ZLZemin Liu
Zemin Liu
CWChe Wang
Che Wang
ZRZiyu Ren
Ziyu Ren
CWChunxiang Wang
Chunxiang Wang
WWWenkang Wang
Wenkang Wang
MSMetin Sitti
Metin Sitti
Micrometre-sized, densely packed natural cilia that perform non-reciprocal 3D motions with dynamically tunable collective patterns are crucial for biological processes such as microscale locomotion 1 , nutrient acquisition 2 , cell trafficking 3–5 and embryonic and neurological development 6–8 . However, replicating these motions in artificial systems remains challenging given the limits of scalable, locally controllable soft-bodied actuation at the micrometre scale. Overcoming this challenge would enhance our understanding of ciliary dynamics, clarify their biological importance and enable new microscale devices and bioinspired technologies. Here we show a previously unrecognized fast electrical response of micrometre-scale hydrogels, induced by voltages down to 1.5 V without hydrolysis, with bending motions driven by ion migration across a nanometre-scale hydrogel network 3D-printed by two-photon polymerization, occurring within milliseconds. On the basis of these findings, we print gel microcilia arrays composed of a soft acrylic acid-co-acrylamide (AAc-co-AAm) hydrogel (modulus of approximately 1,000 Pa) that respond to electrical stimuli within milliseconds. Each microcilium measures 2–10 µm in diameter and 18–90 µm in height, achieving 3D rotational bending motion at up to 40 Hz, mirroring the geometry and dynamics of natural cilia. These gel microcilia maintain functionality after 330,000 continuous actuation cycles with less than 30% performance degradation. The gel microcilia arrays can be integrated on flexible polyimide substrates and fabricated at large scale using conventional lithography techniques. They also offer individual dynamic control by means of microelectrode arrays and enable fluid manipulation and particle transport at the micrometre scale.

1 February 2019 in Journal of Biomedical Nanotechnology
Verified
Journal Article
Closed access
MWMin Wei
Min Wei
ZFZhenfa Fu
Zhenfa Fu
CWChe Wang
Che Wang
WZWei Zheng
Wei Zheng
SLSong Li
Song Li
WLWeidong Le
Weidong Le
In this study, we aimed to investigate the in vitro impacts and mechanisms of graphene oxide (GO) nanocolloids on autophagy in mouse embryonic stem cells (mESCs). Our results showed that GO nanocolloids treatment induced autophagosome accumulation in mESCs. In addition, we found that this effect was mediated by the blockade of autophagic flux rather than autophagic induction, as evidenced by the elevated autophagic substrate SQSTM1/p62 level and LC3B turn over. Moreover, our data further revealed that GO nanocolloids disrupted autophagic flux by impairing lysosomal function, including lysosomal alkalinization and lysosome membrane permeabilization. These results indicate that GO nanocolloids can block autophagic flux in mESCs via autophagy-lysosome dysfunction. Our findings may reveal the putative mechanism of GO nanocolloids-modulated autophagy and provide experimental evidence for the importance of future safety evaluation of nanomaterials.

Verified
Dataset
Open access
ZYZhong‐Lu You
Zhong‐Lu You
XWXiao-Ling Wang
Xiao-Ling Wang
JZJicai Zhang
Jicai Zhang
CWChe Wang
Che Wang
XZXiaoshuang Zhou
Xiaoshuang Zhou