Ossama Merroun

Ossama Merroun

Auto-generated profile, based on publicly available information

Ossama Merroun

Laboratory of Science Engineering, Ecole Nationale Supérieure d'Arts et Métiers, Casablanca, Morocco

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2016 in Renewable Energy
Verified
Journal Article
Closed access
SBS. Benyakhlef
S. Benyakhlef
AMA. Al Mers
A. Al Mers
OMO. Merroun
O. Merroun
ABA. Bouatem
A. Bouatem
NBN. Boutammachte
N. Boutammachte
EZElmoukhtar ZEMMOURI
Elmoukhtar ZEMMOURI

1 October 2010 in Radiation Physics and Chemistry
Verified
Journal Article
Closed access
BBB. El Bakkari
B. El Bakkari
BNB. Nacir
B. Nacir
TBT. El Bardouni
T. El Bardouni
CYC. El Younoussi
C. El Younoussi
OMO. Merroun
O. Merroun
MCM. Chakir
M. Chakir

23 October 2012 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
JBJ. Brun
J. Brun
CRC. Reynard-Carette
C. Reynard-Carette
ALA. Lyoussi
A. Lyoussi
OMO. Merroun
O. Merroun
MCM. Carette
M. Carette
JVJ.-F. Villard
J.-F. Villard
Online nuclear measurements inside experimental channels of material testing reactors (MTRs) are needed for experimental works (to design mock-ups) and for numerical works (input data) in order to better understanding complex phenomena occurring during the accelerated ageing of materials and the irradiation of nuclear fuels. In this paper, we focus only on one kind of measurements: nuclear heating performed by means of a radiometric calorimeter. The aims of numerical and experimental works are firstly to optimize the sensor response: in particular the sensitivity for new energy deposit ranges (new lower nuclear heating level in the reflector), and then to miniaturize and adapt this sensor for irradiation conditions in the Jules Horowitz Reactor (JHR). A calorimeter, developed previously by the CEA, is studied. It corresponds to a graphite differential calorimeter. It is used with a nonadiabatic mode called heat flow mode too. Experimental calibration of the sample cell is presented. In that case, energy deposit is simulated by Joule effect and the sample cell is inserted into a bath at a regulated temperature and controlled flow. The response of the sensor is discussed versus electrical power imposed for two flow rates. Numerical works show the influence of the gas conductivity and of specific dimensions on the cell sensitivity.

1 January 2011 in Nuclear Engineering and Design
Verified
Journal Article
Closed access
YBY. Boulaich
Y. Boulaich
BNB. Nacir
B. Nacir
TBT. El Bardouni
T. El Bardouni
MZM. Zoubair
M. Zoubair
BBB. El Bakkari
B. El Bakkari
ECE. Chakir
E. Chakir


1 June 2011
Verified
Conference Paper
Closed access
DFD. Fourmentel
D. Fourmentel
JVJ-F. Villard
J-F. Villard
ALA. Lyoussi
A. Lyoussi
CRC. Reynard-Carette
C. Reynard-Carette
GBG. Bignan
G. Bignan
JAJ. Andre
J. Andre
We study the combined analysis of nuclear measurements to improve the knowledge of the irradiation conditions in the experimental locations of the future Jules Horowitz Reactor (JHR). The goal of the present work is to measure more accurately neutron flux, photon flux and nuclear heating in the reactor. In a Material Testing Reactor (MTR), nuclear heating is a crucial parameter to design the experimental devices to be irradiated in harsh nuclear conditions. This parameter drives the temperature of the devices and of the samples. The numerical codes can predict this parameter but in-situ measurements are necessary to reach the expected accuracy. For this reason, one objective of the IN-CORE program [1] is to study the combined measurements of neutron and photon flux and their cross advanced interpretation. It should be reminded that both neutron and photon sensors are not totally selective as their signals are due to neutron and photon interactions. We intend to measure the neutron flux by three different kinds of sensors (Uranium Fission chamber, Plutonium Fission chamber and Self Powered Neutron Detector), the photon flux by two different sensors (Ionization chamber and Self Powered Gamma Detector) and the nuclear heating by two different ones (Differential calorimeter and Gamma Thermometer). For the same parameter, we expect that the use of different kinds of sensors will allow a better estimation of the aimed parameter by mixing different spectrum responses and different neutron and gamma contributions. An experimental test called CARMEN-1 is scheduled in OSIRIS reactor (CEA Saclay - France) at the end of 2011, with the goal to map irradiation locations in the reactor reflector to get a first validation of the analysis model. This article focuses on the sensor selection for CARMEN-1 experiment and to the way to link neutron and photon flux measurements in view to reduce their uncertainties but also to better assess the neutron and photon contributions to nuclear heating.