Iwan Setiawan

Iwan Setiawan

Auto-generated profile, based on publicly available information

Iwan Setiawan

National Research and Innovation Agency (BRIN)

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 November 2016
Verified
Conference Paper
Closed access
ISIwan Setiawan
Iwan Setiawan
CKCees Keyer
Cees Keyer
FBFrits Buesink
Frits Buesink
FLFrank Leferink
Frank Leferink
Communication loss in Power Line Telecommunication (PLT) caused by conducted electromagnetic interferences (EMI) is conventionally mitigated by replacing, changing, disconnecting or even by installing new equipment which means high cost. A different approach which uses information of cyclic short-time interference as a tool to replace the hardware approach is proposed in this paper. The concept uses time and frequency domain information simultaneously which has advantages over the approach that uses frequency only by trying to control the permitted level of spectral interference. The proposed concept will allow setting of dynamic levels for conducted electromagnetic interference requirements to enable PLT technology development.

1 September 2017
Verified
Conference Paper
Closed access
ISIwan Setiawan
Iwan Setiawan
Niek MoonenNiek Moonen
Niek Moonen
FBFrits Buesink
Frits Buesink
FLFrank Leferink
Frank Leferink
Measuring magnetic fields of equipment under test at low frequencies which is received by loop antennas using an EMI receiver with small bandwidths takes much time and can even reach a week for a standard measurement. This waste in time could be avoided by applying time domain measurements. Commercial time-domain EMI (TDEMI) measurement equipment are sampling at the intermediate frequency, and are still relatively expensive. Base-band sampling using low-cost digitizers, or an oscilloscope, is proposed in this paper. The measured data is converted to the typical results in frequency domain via fast Fourier transform, while the necessary large dynamic range is achieved via oversampling. This methodology decreases the cost of the test equipment, but most of all reduces the measurement time drastically compared to the classical frequency domain measurement approach. The setup is described. Measurements with a conventional receiver parallel to the digitizer using a signal generator powering a radiating loop have been performed. Also measurements on an actual interfering source with pulsed magnetic fields are performed. It is shown that the measurement results are the same, while the measurement time has been reduced drastically.

1 May 2016
Verified
Conference Paper
Closed access
ISIwan Setiawan
Iwan Setiawan
CKCees Keyer
Cees Keyer
MAMarco Azpurua
Marco Azpurua
FSFerran Silva
Ferran Silva
FLFrank Leferink
Frank Leferink
Conducted interference caused by equipment connected to power supply networks, and the interference in these networks, is conventionally measured using (slow) scanning tuned electromagnetic interference (EMI) receivers. A voltage sensor which separates common mode and differential mode in a three-phase setup combined with a 8-channel digital oscilloscope allows measuring voltage and current via many samples in the three phases plus neutral. Using fast fourier transform for the data processing the conventional amplitude-as-function-of-frequency plots, similar to what would be obtained using conventional EMI receivers, can be generated. But with the presented measurement technique it is also possible to present time-frequency plots in a waterfall diagram. The time - domain measurement technique shows that the conducted noise is cyclic short-time interference.

1 October 2019
Verified
Conference Paper
Closed access
HPHeri Prasetyo
Heri Prasetyo
DRDidi Rosiyadi
Didi Rosiyadi
BHBambang Harjito
Bambang Harjito
ISIwan Setiawan
Iwan Setiawan
This paper presents a new technique for generating a set of shared image from a single secret image under the bit plane slicing-based approach. The proposed method inherits the usability and effectiveness of the former Progressive Visual Secret Sharing (PVSS) task. The proposed scheme also overcomes the slight limitation of former scheme on the lossy recovered secret image. As documented in Experimental Section, the proposed method achieves lossless recovered secret image, at the same time, it offers better performance compared to the former scheme. In addition, this finding is also supported with the theoretical analysis.

1 June 2017
Verified
Conference Paper
Closed access
ISIwan Setiawan
Iwan Setiawan
CKCees Keyer
Cees Keyer
FLFrank Leferink
Frank Leferink
Conflicts of interest in determining permitted levels of EMI of electronic products between different standard committees result in a deadlock. In this context, the conventional approach used in defining the levels is not sufficient anymore to overcome contemporary EMI cases due to technology which rapidly advances. On the other hand, customers need to be protected by EMI standards which must adapt to this change. In the case of smart grids, the challenge is how to manage coexistence between the advanced electronics and communication services without the need to first eliminate interfering signals to allow power line telecommunication (PLT) which is at the same time an interfering signal. To reach this goal, we propose a novel approach for achieving EMC (EM compatibility) by using limits in both the time and the frequency domain while considering PLT as a boundary condition instead of using conventional EMI standards which are based on frequency domain limits only.

1 April 2025 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
ISIwan Setiawan
Iwan Setiawan
RHRachmat Hidayat
Rachmat Hidayat
ANAbdul Mahatir Najar
Abdul Mahatir Najar
AJAgus Indra Jaya
Agus Indra Jaya
DRDidi Rosiyadi
Didi Rosiyadi
Noise in electronic components of computed tomography (CT) detectors behaves like a virus that infects visual quality of CT scans and might distort clinical diagnosis. Modern CT detector technology incorporates high-quality electronic components in conjunction with signal and image processing to ensure optimal image quality while retaining benign doses of x-rays. In this study, a new strategy in signal and image processing directions is proposed by finding the most optimal wavelet base for denoising low-dose CT scan data. The process begins by selecting the appropriate wavelet bases for CT image denoising, followed by a wavelet decomposition, thresholding, and reconstruction. Other methods, such as graph wavelet and learning-based, are used to assess the consistency of the outcomes. The wavelet base of biorthogonal 5.5 achieves the highest optimum performance for CT image denoising. Meanwhile, the Daubechies wavelet base is inconsistent and performs poorly compared to the optimum base. This research highlights the importance of wavelet properties such as orthogonality, regularity, and the number of vanishing moments in selecting an appropriate wavelet basis for noise reduction in CT images.