Purpose We report on the development of the open‐source cross‐platform radiation treatment planning toolkit matRad and its comparison against validated treatment planning systems. The toolkit enables three‐dimensional intensity‐modulated radiation therapy treatment planning for photons, scanned protons and scanned carbon ions. Methods matRad is entirely written in Matlab and is freely available online. It re‐implements well‐established algorithms employing a modular and sequential software design to model the entire treatment planning workflow. It comprises core functionalities to import DICOM data, to calculate and optimize dose as well as a graphical user interface for visualization. matRad dose calculation algorithms (for carbon ions this also includes the computation of the relative biological effect) are compared against dose calculation results originating from clinically approved treatment planning systems. Results We observe three‐dimensional γ‐analysis pass rates ≥ 99.67% for all three radiation modalities utilizing a distance to agreement of 2 mm and a dose difference criterion of 2%. The computational efficiency of matRad is evaluated in a treatment planning study considering three different treatment scenarios for every radiation modality. For photons, we measure total run times of 145 s–1260 s for dose calculation and fluence optimization combined considering 4–72 beam orientations and 2608–13597 beamlets. For charged particles, we measure total run times of 63 s–993 s for dose calculation and fluence optimization combined considering 9963–45574 pencil beams. Using a CT and dose grid resolution of 0.3 cm3 requires a memory consumption of 1.59 GB–9.07 GB and 0.29 GB–17.94 GB for photons and charged particles, respectively. Conclusion The dosimetric accuracy, computational performance and open‐source character of matRad encourages a future application of matRad for both educational and research purposes.
Filters are commonly used to enhance specific structures and patterns in images, such as vessels or peritumoral regions, to enable clinical insights beyond the visible image using radiomics. However, their lack of standardization restricts reproducibility and clinical translation of radiomics decision support tools. In this special report, teams of researchers who developed radiomics software participated in a three-phase study (September 2020 to December 2022) to establish a standardized set of filters. The first two phases focused on finding reference filtered images and reference feature values for commonly used convolutional filters: mean, Laplacian of Gaussian, Laws and Gabor kernels, separable and nonseparable wavelets (including decomposed forms), and Riesz transformations. In the first phase, 15 teams used digital phantoms to establish 33 reference filtered images of 36 filter configurations. In phase 2, 11 teams used a chest CT image to derive reference values for 323 of 396 features computed from filtered images using 22 filter and image processing configurations. Reference filtered images and feature values for Riesz transformations were not established. Reproducibility of standardized convolutional filters was validated on a public data set of multimodal imaging (CT, fluorodeoxyglucose PET, and T1-weighted MRI) in 51 patients with soft-tissue sarcoma. At validation, reproducibility of 486 features computed from filtered images using nine configurations × three imaging modalities was assessed using the lower bounds of 95% CIs of intraclass correlation coefficients. Out of 486 features, 458 were found to be reproducible across nine teams with lower bounds of 95% CIs of intraclass correlation coefficients greater than 0.75. In conclusion, eight filter types were standardized with reference filtered images and reference feature values for verifying and calibrating radiomics software packages. A web-based tool is available for compliance checking.
Purpose: We assessed the predictive potential of positron emission tomography (PET)/CT-based radiomics, lesion volume, and routine blood markers for early differentiation of pseudoprogression from true progression at 3 months.Experimental Design: 112 patients with metastatic melanoma treated with immune checkpoint inhibition were included in our study. Median follow-up duration was 22 months. 716 metastases were segmented individually on CT and 2[18F]fluoro-2-deoxy-D-glucose (FDG)-PET imaging at three timepoints: baseline (TP0), 3 months (TP1), and 6 months (TP2). Response was defined on a lesion-individual level (RECIST 1.1) and retrospectively correlated with FDG-PET/CT radiomic features and the blood markers LDH/S100. Seven multivariate prediction model classes were generated.Results: Two-year (median) overall survival, progression-free survival, and immune progression–free survival were 69% (not reached), 24% (6 months), and 42% (16 months), respectively. At 3 months, 106 (16%) lesions had progressed, of which 30 (5%) were identified as pseudoprogression at 6 months. Patients with pseudoprogressive lesions and without true progressive lesions had a similar outcome to responding patients and a significantly better 2-year overall survival of 100% (30 months), compared with 15% (10 months) in patients with true progressions/without pseudoprogression (P = 0.002). Patients with mixed progressive/pseudoprogressive lesions were in between at 53% (25 months). The blood prediction model (LDH+S100) achieved an AUC = 0.71. Higher LDH/S100 values indicated a low chance of pseudoprogression. Volume-based models: AUC = 0.72 (TP1) and AUC = 0.80 (delta-volume between TP0/TP1). Radiomics models (including/excluding volume-related features): AUC = 0.79/0.78. Combined blood/volume model: AUC = 0.79. Combined blood/radiomics model (including volume-related features): AUC = 0.78. The combined blood/radiomics model (excluding volume-related features) performed best: AUC = 0.82.Conclusions: Noninvasive PET/CT-based radiomics, especially in combination with blood parameters, are promising biomarkers for early differentiation of pseudoprogression, potentially avoiding added toxicity or delayed treatment switch.
Objectives: In this study, we aimed to assess the impact of different CT reconstruction kernels on the stability of radiomic features and the transferability between different diseases and tissue types. Three lung diseases were evaluated, i.e. non-small cell lung cancer (NSCLC), malignant pleural mesothelioma (MPM) and interstitial lung disease related to systemic sclerosis (SSc-ILD) as well as four different tissue types, i.e. primary tumor, largest involved lymph node ipsilateral and contralateral lung. Methods: Pre-treatment non-contrast enhanced CT scans from 23 NSCLC, 10 MPM and 12 SSc-ILD patients were collected retrospectively. For each patient, CT scans were reconstructed using smooth and sharp kernel in filtered back projection. The regions of interest (ROIs) were contoured on the smooth kernel-based CT and transferred to the sharp kernel-based CT. The voxels were resized to the largest voxel dimension of each cohort. In total, 1386 features were analyzed. Feature stability was assessed using the intraclass correlation coefficient. Features above the stability threshold >0.9 were considered stable. Results: We observed a strong impact of the reconstruction method on stability of the features (at maximum 26% of the 1386 features were stable). Intensity features were the most stable followed by texture and wavelet features. The wavelet features showed a positive correlation between percentage of stable features and size of the ROI (R2 = 0.79, p = 0.005). Lymph node radiomics showed poorest stability (<10%) and lung radiomics the largest stability (26%). Robustness analysis done on the contralateral lung could to a large extent be transferred to the ipsilateral lung, and the overlap of stable lung features between different lung diseases was more than 50%. However, results of robustness studies cannot be transferred between tissue types, which was investigated in NSCLC and MPM patients; the overlap of stable features for lymph node and lung, as well as for primary tumor and lymph node was very small in both disease types. Conclusion: The robustness of radiomic features is strongly affected by different reconstruction kernels. The effect is largely influenced by the tissue type and less by the disease type. Advances in knowledge: The study presents to our knowledge the most complete analysis on the impact of convolution kernel on the robustness of CT-based radiomics for four relevant tissue types in three different lung diseases.
Purpose: Xerostomia is a common side effect of radiotherapy resulting from excessive irradiation of salivary glands. Typically, xerostomia is modeled by the mean dose-response characteristic of parotid glands and prevented by mean dose constraints to either contralateral or both parotid glands. The aim of this study was to investigate whether normal tissue complication probability (NTCP) models based on the mean radiation dose to parotid glands are suitable for the prediction of xerostomia in a highly conformal low-dose regime of modern intensity-modulated radiotherapy (IMRT) techniques. Material and methods: We present a retrospective analysis of 153 head and neck cancer patients treated with radiotherapy. The Lyman Kutcher Burman (LKB) model was used to evaluate predictive power of the parotid gland mean dose with respect to xerostomia at 6 and 12 months after the treatment. The predictive performance of the model was evaluated by receiver operating characteristic (ROC) curves and precision-recall (PR) curves. Results: Average mean doses to ipsilateral and contralateral parotid glands were 25.4 Gy and 18.7 Gy, respectively. QUANTEC constraints were met in 74% of patients. Mild to severe (G1+) xerostomia prevalence at both 6 and 12 months was 67%. Moderate to severe (G2+) xerostomia prevalence at 6 and 12 months was 20% and 15%, respectively. G1 + xerostomia was predicted reasonably well with area under the ROC curve ranging from 0.69 to 0.76. The LKB model failed to provide reliable G2 + xerostomia predictions at both time points. Conclusions: Reduction of the mean dose to parotid glands below QUANTEC guidelines resulted in low G2 + xerostomia rates. In this dose domain, the mean dose models predicted G1 + xerostomia fairly well, however, failed to recognize patients at risk of G2 + xerostomia. There is a need for the development of more flexible models able to capture complexity of dose response in this dose regime.
Antifibrotic therapy with nintedanib is the clinical mainstay in the treatment of progressive fibrosing interstitial lung disease (ILD). High-dimensional medical image analysis, known as radiomics, provides quantitative insights into organ-scale pathophysiology, generating digital disease fingerprints. Here, we performed an integrative analysis of radiomic and proteomic profiles (radioproteomics) to assess whether changes in radiomic signatures can stratify the degree of antifibrotic response to nintedanib in (experimental) fibrosing ILD. Unsupervised clustering of delta radiomic profiles revealed 2 distinct imaging phenotypes in mice treated with nintedanib, contrary to conventional densitometry readouts, which showed a more uniform response. Integrative analysis of delta radiomics and proteomics demonstrated that these phenotypes reflected different treatment response states, as further evidenced on transcriptional and cellular levels. Importantly, radioproteomics signatures paralleled disease- and drug-related biological pathway activity with high specificity, including extracellular matrix (ECM) remodeling, cell cycle activity, wound healing, and metabolic activity. Evaluation of the preclinical molecular response–defining features, particularly those linked to ECM remodeling, in a cohort of nintedanib-treated fibrosing patients with ILD, accurately stratified patients based on their extent of lung function decline. In conclusion, delta radiomics has great potential to serve as a noninvasive and readily accessible surrogate of molecular response phenotypes in fibrosing ILD. This could pave the way for personalized treatment strategies and improved patient outcomes.