2 April 2014 in IEEE Transactions on Medical Imaging
Colorectal polyps are important precursors to colon cancer, a major health problem. Colon capsule endoscopy is a safe and minimally invasive examination procedure, in which the images of the intestine are obtained via digital cameras on board of a small capsule ingested by a patient. The video sequence is then analyzed for the presence of polyps. We propose an algorithm that relieves the labor of a human operator analyzing the frames in the video sequence. The algorithm acts as a binary classifier, which labels the frame as either containing polyps or not, based on the geometrical analysis and the texture content of the frame.We assume that the polyps are characterized as protrusions that are mostly round in shape. Thus, a best fit ball radius is used as a decision parameter of the classifier. We present a statistical performance evaluation of our approach on a data set containing over 18 900 frames from the endoscopic video sequences of five adult patients. The algorithm achieves 47% sensitivity per frame and 81% sensitivity per polyp at a specificity level of 90%. On average, with a video sequence length of 3747 frames, only 367 false positive frames need to be inspected by an operator.
1 January 2014 in Communications in Mathematical Sciences
The objective of quantitative photoacoustic tomography (QPAT) is to reconstruct optical and thermodynamic properties of heterogeneous media from data of absorbed energy distribution inside the media. There have been extensive theoretical and computational studies on the inverse problem in QPAT, however, mostly in the diffusive regime. We present in this work some numerical reconstruction algorithms for multi-source QPAT in the radiative transport regime with energy data collected at either single or multiple wavelengths. We show that when the medium to be probed is non-scattering, explicit reconstruction schemes can be derived to reconstruct the absorption and the Gruneisen coefficients. When data at multiple wavelengths are utilized, we can reconstruct simultaneously the absorption, scattering and Gruneisen coefficients. We show by numerical simulations that the reconstructions are stable.Comment: 40 pages, 13 figure
1 January 2016 in SIAM Journal on Imaging Sciences
We estimate the wave speed in the acoustic wave equation from boundary measurements by constructing a reduced-order model (ROM) matching discrete time-domain data. The state-variable representation...
19 November 2014 in Inverse Problems
1 March 2013 in Inverse Problems
1 January 2020 in SIAM Journal on Imaging Sciences
We study an inverse scattering problem for a generic hyperbolic system of equations with an unknown coefficient called the reflectivity. The solution of the system models waves (sound, electromagne...