20 March 2025 in Journal of Electromagnetic Waves and Applications
15 May 2025 in IEEE Transactions on Automation Science and Engineering
This paper investigates the stochastic stability of the continuous-discrete maximum correntropy cubature Kalman filter (CD-MCCKF), which is developed by embedding the maximum correntropy criterion as an optimization strategy into the continuous-discrete filtering architecture. By assuming that the relevant functions satisfy certain properties, we first establish the convergence of the employed numerical method and fixed-point iteration technique. Subsequently, combined with the findings on the error covariance boundary, it is proved that the estimation error of CD-MCCKF keeps mean-square bounded under specific conditions. To validate this stability analysis finding and evaluate the filtering performance, we conduct a classical case study. Simulation results confirm that CD-MCCKF not only maintains bounded estimation errors, but also surpasses the conventional continuous-discrete filters in terms of accuracy and convergence.
1 May 2021 in Review of Scientific Instruments
The plasma current density profile plays a key role in the development of a high poloidal beta scenario, which is essential for long-pulse and high-performance plasma operation on a tokamak. Based on the polarimetry technique, a Motional Stark Effect (MSE) diagnostic has been built on the Experimental Advanced Superconducting Tokamak. To be prepared for real-time (RT) feedback control of the plasma current density profile in the future, a RT signal processing system has been developed. The RT signal processing system is composed of three functional modules: analog-to-digital conversion (ADC) module, polarization information extraction module, and digital-to-analog conversion (DAC) module. The final objective of this system is to acquire the polarization information of the MSE. Based on the field-programmable gate array unit, fast Fourier transformation is adopted to process the Photoelastic Modulator (PEM) digital signal, which was converted from a PEM signal via the ADC module. By means of frequency spectrum separation, the components around double modulating frequencies are restored through inverse fast Fourier transformation. Furthermore, the two amplitudes of their corresponding components can be obtained through a digital harmonic analyzer technique. Afterward, the ratio of the two amplitudes is calculated by arc tangent so that the polarization angle is obtained. Finally, the information of this polarization angle is converted into a voltage signal by the DAC module and then output in RT. The test results based on the RT signal processing system are in good agreement with those based on the phase lock-in amplifiers. The working cycle of this system is shorter than 10 ms, which meets the requirements of the MSE diagnostic as a RT controller. The algorithm of RT signal processing and the relevant technology applied for building this system are presented in the main body of this paper in detail.
1 April 2025 in IEEE Transactions on Instrumentation and Measurement
Real-time measurement of polarization angle of the Stark polarized light in motional Stark effect (MSE) diagnostic is essential for obtaining current density distribution, feedback control of which can be utilized to achieve advanced mode of tokamak device. In this paper, a digital lock-in amplifier (DLIA) based on field programmable logic array (FPGA) is developed, which is used for real-time measurement of polarization angle in MSE diagnostic on the Experimental Advanced Superconducting Tokamak (EAST). By demodulating the intensity-modulated polarized light that contains multiple harmonic components, the DLIA-based system can efficiently extract the amplitudes of two second-harmonics and further obtain the polarization angle from the two extracted amplitudes. The operation period of the system is 260.84 μs, which well satisfies the demands of MSE diagnostic for working cycle within 1 ms. Compared with the previous fast Fourier transform (FFT) method, the developed DLIA-based system has a lower latency. Compared to the commercial lock-in amplifiers currently used, the DLIA-based system in this work has the advantages of high integration and directly outputting the polarization angle of the Stark polarized light without extra signal processing. The performance of the DLIA-based system is demonstrated in laboratory test and field test of EAST. The maximum relative error in field test on EAST is less than 5%, meeting the requirement of MSE diagnostic.
27 August 2024 in Journal of Electromagnetic Waves and Applications