Grant A. McCallum

Grant A. McCallum

Auto-generated profile, based on publicly available information

Grant A. McCallum

Neural Engineering Center, Department of Biomedical Engineering Case Western Reserve University Cleveland Ohio USA

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 September 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
GMGrant A. McCallum
Grant A. McCallum
JSJay Shiralkar
Jay Shiralkar
DSDiana Suciu
Diana Suciu
GCGil Covarrubias
Gil Covarrubias
JYJennifer S. Yu
Jennifer S. Yu
Dominique M. DurandDominique M. Durand
Dominique M. Durand
Nerve fibers are known to reside within malignant tumors and the greater the neuronal density the worse prognosis for the patient. Recent discoveries using tumor bearing animal models have eluded to the autonomic nervous system having a direct effect on tumor growth and metastasis. We report the first direct and chronic in vivo measurements of neural activity within tumors. Using a triple-negative mammary cancer mouse model and chronic neural interface techniques, we have recorded neural activity directly within the tumor mass while the tumor grows and metastasizes. The results indicate that there is a strong connection between the autonomic nervous system and the tumor and could help uncover the mechanisms of tumor growth and metastasis.

17 June 2015 in Journal of Neural Engineering
Verified
Journal Article
Open access
PDF file
YDYazan M Dweiri
Yazan M Dweiri
TEThomas Eggers
Thomas Eggers
GMGrant McCallum
Grant McCallum
Dominique M. DurandDominique M. Durand
Dominique M. Durand
Objective. Peripheral nerves carry neural signals that could be used to control hybrid bionic systems. Cuff electrodes provide a robust and stable interface but the recorded signal amplitude is small (<3 μVrms 700 Hz–7 kHz), thereby requiring a baseline noise of less than 1 μVrms for a useful signal-to-noise ratio (SNR). Flat interface nerve electrode (FINE) contacts alone generate thermal noise of at least 0.5 μVrms therefore the amplifier should add as little noise as possible. Since mainstream neural amplifiers have a baseline noise of 2 μVrms or higher, novel designs are required. Approach. Here we apply the concept of hardware averaging to nerve recordings obtained with cuff electrodes. An optimization procedure is developed to minimize noise and power simultaneously. The novel design was based on existing neural amplifiers (Intan Technologies, LLC) and is validated with signals obtained from the FINE in chronic dog experiments. Main results. We showed that hardware averaging leads to a reduction in the total recording noise by a factor of 1/√N or less depending on the source resistance. Chronic recording of physiological activity with FINE using the presented design showed significant improvement on the recorded baseline noise with at least two parallel operation transconductance amplifiers leading to a 46.1% reduction at N = 8. The functionality of these recordings was quantified by the SNR improvement and shown to be significant for N = 3 or more. The present design was shown to be capable of generating <1.5 μVrms total recording baseline noise when connected to a FINE placed on the sciatic nerve of an awake animal. An algorithm was introduced to find the value of N that can minimize both the power consumption and the noise in order to design a miniaturized ultralow-noise neural amplifier. Significance. These results demonstrate the efficacy of hardware averaging on noise improvement for neural recording with cuff electrodes, and can accommodate the presence of high source impedances that are associated with the miniaturized contacts and the high channel count in electrode arrays. This technique can be adopted for other applications where miniaturized and implantable multichannel acquisition systems with ultra-low noise and low power are required.

11 February 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
JMJoseph Theodore Marmerstein
Joseph Theodore Marmerstein
GMGrant A. McCallum
Grant A. McCallum
Dominique M. DurandDominique M. Durand
Dominique M. Durand
The vagus nerve is the largest autonomic nerve and a major target of stimulation therapies for a wide variety of chronic diseases. However, chronic recording from the vagus nerve has been limited, leading to significant gaps in our understanding of vagus nerve function and therapeutic mechanisms. In this study, we use a carbon nanotube yarn (CNTY) biosensor to chronically record from the vagus nerves of freely moving rats for over 40 continuous hours. Vagal activity was analyzed using a variety of techniques, such as spike sorting, spike-firing rates, and interspike intervals. Many spike-cluster-firing rates were found to correlate with food intake, and the neural-firing rates were used to classify eating and other behaviors. To our knowledge, this is the first chronic recording and decoding of activity in the vagus nerve of freely moving animals enabled by the axon-like properties of the CNTY biosensor in both size and flexibility and provides an important step forward in our ability to understand spontaneous vagus-nerve function.

1 December 2023 in Journal of Neural Engineering
Verified
Journal Article
Open access
PDF file
BKB P Kotamraju
B P Kotamraju
TEThomas E Eggers
Thomas E Eggers
GMGrant A McCallum
Grant A McCallum
Dominique M. DurandDominique M. Durand
Dominique M. Durand
Objective. The primary challenge faced in the field of neural rehabilitation engineering is the limited advancement in nerve interface technology, which currently fails to match the mechanical properties of small-diameter nerve fascicles. Novel developments are necessary to enable long-term, chronic recording from a multitude of small fascicles, allowing for the recovery of motor intent and sensory signals. Approach. In this study, we analyze the chronic recording capabilities of carbon nanotube yarn electrodes in the peripheral somatic nervous system. The electrodes were surgically implanted in the sciatic nerve’s three individual fascicles in rats, enabling the recording of neural activity during gait. Signal-to-noise ratio (SNR) and information theory were employed to analyze the data, demonstrating the superior recording capabilities of the electrodes. Flat interface nerve electrode and thin-film longitudinal intrafascicular electrode electrodes were used as a references to assess the results from SNR and information theory analysis. Main results. The electrodes exhibited the ability to record chronic signals with SNRs reaching as high as 15 dB, providing 12 bits of information for the sciatic nerve, a significant improvement over previous methods. Furthermore, the study revealed that the SNR and information content of the neural signals remained consistent over a period of 12 weeks across three different fascicles, indicating the stability of the interface. The signals recorded from these electrodes were also analyzed for selectivity using information theory metrics, which showed an information sharing of approximately 1.4 bits across the fascicles. Significance. The ability to safely and reliably record from multiple fascicles of different nerves simultaneously over extended periods of time holds substantial implications for the field of neural and rehabilitation engineering. This advancement addresses the limitation of current nerve interface technologies and opens up new possibilities for enhancing neural rehabilitation and control.

15 February 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JSJay Shiralkar
Jay Shiralkar
TATiana Anthony
Tiana Anthony
GMGrant A McCallum
Grant A McCallum
Dominique M. DurandDominique M. Durand
Dominique M. Durand
Multiple studies report that melanomas are innervated tumors with sensory and sympathetic fibers where these neural fibers play crucial functional roles in tumor growth and metastasis with branch specificity. Yet there is no study which reports the direct neural recording and its pattern during in-vivo progression of the cancer. We performed daily neural recordings from male and female mice bearing orthotopic metastasizing- melanomas and melanomas with low metastatic poential, derived from B16-F10 and B16-F1 cells, respectively. Further, to explore the origins of neural activity, 6-Hydroxidopamine mediated chemical sympathectomy was performed followed by daily microneurographic recordings. We also performed the daily bioluminescent imaging to track in vivo growth of primary tumors and distant metastasis to the cranial area. Our results show that metastasizing tumors display high levels of neural activity while tumors with low metastatic potential lack it indicating that the presence of neural activity is linked to the metastasizing potential of the tumors. Moreover, the neural activity is not continuous over the tumor progression and has a sex-specific temporal patterns where males have two peaks of high neural activity while females show a single peak. The neural peak activity originated in peripheral sympathetic nerves as sympathectomy completely eliminated the peak activity in both sexes. Peak activities were highly correlated with the distant metastasis in both sexes. These results show that sympathetic neural activity is crucially involved in tumor metastasis and has sex-specific role in malignancy initiation.

20 May 2025 in Journal of Neuroscience Research
Verified
Journal Article
Open access
ARAaron J. Rodrigues
Aaron J. Rodrigues
JMJoseph Theodore Marmerstein
Joseph Theodore Marmerstein
BKBhanu P. Kotamraju
Bhanu P. Kotamraju
GMGrant A. McCallum
Grant A. McCallum
Dominique M. DurandDominique M. Durand
Dominique M. Durand
The vagus nerve, serving as a pivotal link between the brain and vital organs, regulates crucial physiological functions. It plays a central role in maintaining homeostasis within the body and must dynamically adapt to changing conditions such as anesthesia or sleep. While vagal tone, typically estimated indirectly from heart rate variability, has been extensively studied, direct measurement of vagal activity during sleep and anesthesia remains unreported to date. Recent technological advancements have facilitated the recording of vagus nerve activity in freely moving rodents using small, highly flexible carbon nanotube yarns. Consequently, it is now feasible to directly investigate vagal activity during events known to impact homeostasis, such as diurnal variations and anesthesia. In this study, we explore the relationship between anesthesia and vagus nerve activity by comparing the effects of 2% isoflurane anesthesia with activity in freely moving male Sprague Dawley rats. The findings reveal that 2% isoflurane anesthesia significantly suppresses vagus nerve activity, and normal activity levels do not resume until 2 h after the termination of the anesthesia supply. Additionally, we examine the influence of diurnal variations on vagus nerve activity and observe a notable presence of diurnal variations in vagal activity patterns. These results provide insights into the interaction among anesthesia, diurnal variations, and vagal tone, offering valuable understanding of the autonomic nervous system during critical physiological states.