Alexandra Kallitsopoulou

Alexandra Kallitsopoulou

Auto-generated profile, based on publicly available information

Alexandra Kallitsopoulou

IRFU, CEA-Université Paris-Saclay, F-91191 Gif-sur-Yvette

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2024 in Journal of Instrumentation
Verified
Journal Article
Open access
XWX. Wang
X. Wang
RAR. Aleksan
R. Aleksan
YAY. Angelis
Y. Angelis
JBJ. Bortfeldt
J. Bortfeldt
FBF. Brunbauer
F. Brunbauer
YZY. Zhou
Y. Zhou
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bombardment of the CsI photocathodes, alternative photocathode materials are needed to improve the robustness of PICOSEC MM. Diamond-like Carbon (DLC) film have been introduced as a novel robust photocathode material, which have shown promising results. A batch of DLC photocathodes with different thicknesses were produced and evaluated using ultraviolet light. The quantum efficiency measurements indicate that the optimized thickness of the DLC photocathode is approximately 3 nm. Furthermore, DLC photocathodes show good resistance to ion bombardment in aging test compared to the CsI photocathode. Finally, a PICOSEC MM prototype equipped with DLC photocathodes was tested in muon beams. A time resolution of around 42 ps with a detection efficiency of 97% for 150 GeV/c muons were obtained. These results indicate the great potential of DLC as a photocathode for the PICOSEC MM detector.

11 December 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
MLM. Lisowska
M. Lisowska
RAR. Aleksan
R. Aleksan
YAY. Angelis
Y. Angelis
SAS. Aune
S. Aune
JBJ. Bortfeldt
J. Bortfeldt
YZY. Zhou
Y. Zhou

1 November 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
MLM. Lisowska
M. Lisowska
JBJ. Bortfeldt
J. Bortfeldt
FBF. Brunbauer
F. Brunbauer
GFG. Fanourakis
G. Fanourakis
KFK.J. Floethner
K.J. Floethner
YZY. Zhou
Y. Zhou

1 March 2025 in Journal of Instrumentation
Verified
Journal Article
Closed access
YMY. Meng
Y. Meng
RAR. Aleksan
R. Aleksan
YAY. Angelis
Y. Angelis
JBJ. Bortfeldt
J. Bortfeldt
FBF. Brunbauer
F. Brunbauer
YZY. Zhou
Y. Zhou
PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector concept was successfully demonstrated through a single-channel prototype, achieving sub-25 ps time resolution with Minimum Ionizing Particles (MIPs). A series of studies followed, aimed at developing robust, large-area, and scalable detectors with high time resolution, complemented by specialized fast-response readout electronics. This work presents recent advancements towards large-area resistive PICOSEC MM, including 10 × 10 cm2 area prototypes and a 20 × 20 cm2 prototype, which features the jointing of four photocathodes. The time resolution of these detector prototypes was tested during the test beam, achieved a timing performance of around 25 ps for individual pads in MIPs. Meanwhile, customized electronics have been developed dedicated to the high-precision time measurement of the large-area PICOSEC MM. The performance of the entire system was evaluated during the test beam, demonstrating its capability for large-area integration. These advancements highlight the potential of PICOSEC MM to meet the stringent requirements of future particle physics experiments.

16 October 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
AKA. Kallitsopoulou
A. Kallitsopoulou
RAR. Aleksan
R. Aleksan
YAY. Angelis
Y. Angelis
SAS. Aune
S. Aune
JBJ. Bortfeldt
J. Bortfeldt
YZY. Zhou
Y. Zhou

1 April 2026 in Journal of Instrumentation
Verified
Journal Article
Open access
AKA. Kallitsopoulou
A. Kallitsopoulou
SAS. Aune
S. Aune
YAY. Angelis
Y. Angelis
RAR. Aleksan
R. Aleksan
ABA. Bonenfant
A. Bonenfant
YZY. Zhou
Y. Zhou
The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector concept that achieves picosecond-level timing. It couples a Cherenkov radiator, typically an MgF 2 crystal, to a Micromegas-based photodetector equipped with a photocathode, allowing the fast photoelectron-induced signal to suppress the intrinsic time jitter characteristic of gaseous detectors. This design enables sub-20 ps timing precision while preserving the robustness and scalability of Micro-Pattern Gaseous Detector (MPGD) technologies. The 96-pad PICOSEC-MM detector represents the latest advancement in this development, optimized for precision timing in high-energy physics. Building upon the R&D insights obtained with earlier 7-pad resistive prototypes, this large-area demonstrator was developed to validate the scalability, uniformity, and robustness of the technology for integration into the ENUBET project. The detector employs a 2.5 nm Diamond-Like Carbon (DLC) photocathode with a Micromegas board equipped with surface resistivity of 10 MΩ/□, providing an excellent timing performance. The prototype was characterized using 150 GeV/ c muons at the CERN SPS beamline, with one-third of the active area instrumented during each run. A dedicated alignment procedure, developed for multi-pad PICOSEC-MM systems, was used to reconstruct the pad centers and combine measurements across different detector regions. The measured timing resolution was 43 ps across the instrumented pads, while the Signal Arrival Time (SAT) distributions exhibited a good uniformity among the detector area that was tested. Mechanical flatness was identified as a key factor influencing timing precision. Maintaining a planarity tolerance within 10 μm is therefore critical to preserve a good timing resolution over large active areas. The successful operation of the 96-pad demonstrator confirms the scalability of the PICOSEC-MM concept marking a significant step toward implementing robust, high-granularity, picosecond-level gaseous timing detectors in monitored neutrino beam experiments such as ENUBET.