A significant part of reinforced concrete structures is subjected to intensive environmental impact during operation. This can cause local destruction and failure of buildings if obligatory measures are not taken to protect them from corrosion. This is especially true for industrial buildings, where the environment could be contaminated with aggressive products or waste. An important issue is the development of methods for calculating the load-bearing capacity and serviceability of reinforced concrete structures with corrosion damage. The main reason for this is the necessity to determine the durability and reliability of buildings and structures and the estimation of their safe operation time. As corrosion damages of concrete are a critical issue, more detailed experimental studies are needed. This paper presents experimental studies of concrete prisms under the simultaneous action of an aggressive environment and a constant level of compressive force. In total, 32 prisms under different loading conditions and in different aggressive medium were tested. Samples were divided in series, for which different load levels were chosen (, , ). Additionally, control samples in the air and immersed in water were tested. During the experiment, different parameters were monitored and recorded: decrease of cross-sectional size, the temperature and environmental humidity. Results of the study showed that destruction occurred due to the presence of corrosion damages of concrete and a reduction of the cross-sectional area. The stresses in the concrete at the destruction stage were less than the value of the prism strength by 10–12%. It was established that along the contour of the section, there is a partially degraded layer of concrete of 1.5–3.7 mm thickness, with corrosion microcracks and corrosion products. Additionally, experimental and theoretical diagrams of concrete with corrosion damages were obtained and compared. The ultimate deformations of concrete with corrosion damage, which correspond to the prismatic strength of concrete, in comparison with undamaged concrete were lower by 11–18%. Therefore, the concrete strength is decreased during exploitation under loading in an aggressive environment, which needs to be taken into account during calculations.
1 January 2021 in IOP Conference Series: Materials Science and Engineering
The article presents the development of a method of experimental study of reinforced concrete beams with damaged steel reinforcement. In addition, the purpose is to conduct experimental tests of undamaged samples with steel reinforcement of 20- and 16-mm diameter. Also, the 20 mm steel bars were damaged to the area equal to 16 mm samples, experimental tests of such samples were performed and corresponding analysis and comparison of the results of both tests was conducted. According to the study program, 6 beam samples were tested. Two of them were undamaged control samples with single load bearing reinforcement of Ø20 mm diameter; 2 samples with Ø20 mm reinforcement had about 36% damages (which corresponds to area of the 16 mm diameter samples) and 2 samples with Ø16 mm single reinforcement, which corresponds to 36% load bearing reinforcement damage of control samples (the area of 36% damages of 20 mm samples corresponds to 16 mm diameter). The experimental study identified the strength and strain parameters of reinforced concrete beams with damages in the load bearing stretched reinforcement due to the action of the bending moment, which causes the exhaustion of the bearing capacity.
20 November 2021 in Production Engineering Archives
Each structure is exposed to different influences during operation. As a result, there are various defects and damages of these elements that affect their safe operation. The article presents the results of experimental studies of reinforced concrete beams with damages to stretched reinforcement made with and without initial load application. As the damages were accepted one or five Ø5.6 mm holes. In one case, the damage was made until the beam destruction (up to the 8.4 mm opening) Control samples of both series were destroyed due to crushing of the compressed zone of concrete. Samples that were damaged without initial loading collapsed due to rupture of the stretched reinforcement. The same type of failure was identified for damages at the operational load level.
30 August 2021 in Eastern-European Journal of Enterprise Technologies
This paper reports the improved and verified procedure for calculating reinforced concrete beams affected by damage to stretched reinforcement when loaded. The main results from testing the reinforced concrete beams with damage in the stretched zone in the form of one hole in the reinforcement in the middle of the beam are given. The variable parameter of the study was the level of load resulting in the damage. It acquired values of 0, 30 %, 50 %, 70 % of the bearing capacity of control undamaged samples. Overall, the results of testing 12 samples are given. A new procedure has been proposed for taking into consideration changes in the mechanical characteristics of stretched reinforcement arising from its damage. This makes it possible to more accurately establish the bearing capacity of reinforced concrete bended elements affected by damage to their reinforcement during operation. The analysis of the calculation, compared with experimental quantities, led to a conclusion that the strain model could determine when the bearing capacity of reinforced concrete beams without damage and with damage to working reinforcement is exhausted. Based on the improved algorithm, the principle of using a strain model was proposed to establish when the bearing capacity of damaged samples, taking into consideration the effect of the load level, is exhausted. The theoretical estimation, considering when the bearing capacity is exhausted, showed results that are 3...21 % less than the experimental values, which ensures reliability of calculation of such structures. The proposed calculation provides a new approach to determining the bearing capacity of reinforced concrete beams damaged during operation. That, in turn, makes it possible to more accurately determine the residual bearing capacity of structures and increases the safety of their operation.