15 April 2019 in Journal of Laser Applications
As a result of the rapidly growing importance of applications in electro mobility that require a precisely defined laser weld depth, the demand for inline process monitoring and control is increasing. To overcome the challenges in process data acquisition, this paper proposes the application of a novel sensor concept for deep penetration laser beam welding with high brilliance laser sources. The experiments show that optical coherence tomography (OCT) can be used to measure the weld depth by comparing the distance to the material surface with the distance to the keyhole bottom measured by the sensor. Within the presented work, the measuring principle was used for the first time to observe a welding process with a highly focused laser beam source. First, a preliminary experimental study was carried out to evaluate the influence of the angle of incidence, the material, and the weld joint geometry on the quality of the sensor signal. When using a multimode fiber laser with a focus diameter of 320 μm, the measurements showed a distinct behavior for aluminum and copper. The findings about the measurement signal properties were then applied to laser beam welding with a single-mode fiber laser with a spot diameter of only 55 μm. The spot diameter of the OCT measuring beam was about 50 μm and thus only slightly smaller than that of the single-mode processing beam. A wide variety of tests were carried out to determine the limits of the measurement procedure. The results show that the application of OCT allows inline monitoring of the weld depth using both a multimode and a highly focused single-mode laser beam. In addition, various influences on the signal were identified, e.g., the material-specific melt pool dynamics as well as several characteristic reflection and absorption properties.
15 April 2019 in Journal of Laser Applications
Remote laser beam welding significantly outperforms conventional joining techniques in terms of flexibility and productivity. This process benefits in particular from a highly focused laser radiation and thus from a well-defined heat input. The small spot sizes of high brilliance laser beam sources, however, require a highly dynamic and precise positioning of the beam. Also, the laser intensities typically applied in this context result in high process dynamics and in demand for a method to ensure a sufficient weld quality. A novel sensor concept for remote laser processing based on optical coherence tomography (OCT) was used for both quality assurance and edge tracking. The OCT sensor was integrated into a 3D scanner head equipped with an additional internal scanner to deflect the measuring beam independently of the processing beam. With this system, the surface topography of the process zone as well as the surrounding area can be recorded. Fundamental investigations on aluminum, copper, and galvanized steel were carried out. Initially, the influence of the material, the angle of incidence, the welding position within the scanning field, and the temperature on the OCT measuring signal were evaluated. Based on this, measuring strategies for edge tracking were developed and validated. It was shown that orthogonal measuring lines in the advance of the process zone can reliably track the edge of a fillet weld. By recording the topography in the trailing area of the process zone, it was possible to assess the weld seam quality. Comparing the results to microscopic measurements, it was shown that the system is capable of clearly identifying characteristic features of the weld seam. Also, it was possible to observe an influence of the welding process on the surface properties in the heat-affected zone, based on the quality of the measuring signal.
30 April 2020 in Journal of Laser Applications
The aluminum alloy AA6082 is often used in high-voltage storage systems due to its favorable electrical and mechanical properties. Laser beam welding is a flexible process for producing the required welds. To protect the sensitive components of the battery cells, the required weld depth must be maintained in order to avoid destruction of the components and to reduce the number of defective parts. Optical coherence tomography (OCT) is a promising method for the inline monitoring of the deep welding process, since the depth of the vapor capillary can be measured without the influence of process emissions such as process light or welding fumes. Due to the robustness of the measurement method, the measured depth of the keyhole can be used as an input variable for a process control. However, there is a geometric difference between the optically detectable keyhole depth and the melt pool depth. This depth is additionally determined by fluid dynamic processes in the melt pool. In order to consider the difference between the melt pool depth and the keyhole depth when evaluating OCT measurement signals, a thermal simulation model was developed. By iteratively adapting the keyhole geometry in the simulation on the basis of genetic algorithms, an optimization of the correlation was achieved. The model was calibrated based on the comparison of metallographic cross sections with the calculated melt pool geometries. The results were used to provide a database for improving the performance of the signal processing algorithms. Based on the calculation results, it was possible to determine and quantify a dependence of the melt film thickness below the keyhole on the welding process parameters. By including the melt thickness below the keyhole, it was possible to increase the accuracy in the interpretation of OCT data with regard to the welding depth. The quantity can thus be used as an input quantity for signal processing algorithms for OCT data evaluation.