Petr Bruza

Petr Bruza

Auto-generated profile, based on publicly available information

Petr Bruza

Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 April 2018 in Nature Communications
Verified
Journal Article
Open access
PDF file
JKJake D. Koralek
Jake D. Koralek
JKJongjin B. Kim
Jongjin B. Kim
PBPetr Brůža
Petr Brůža
CCChandra Breanne Curry
Chandra Breanne Curry
ZCZhijiang Chen
Zhijiang Chen
DDDaniel P. DePonte
Daniel P. DePonte
The physics and chemistry of liquid solutions play a central role in science, and our understanding of life on Earth. Unfortunately, key tools for interrogating aqueous systems, such as infrared and soft X-ray spectroscopy, cannot readily be applied because of strong absorption in water. Here we use gas-dynamic forces to generate free-flowing, sub-micron, liquid sheets which are two orders of magnitude thinner than anything previously reported. Optical, infrared, and X-ray spectroscopies are used to characterize the sheets, which are found to be tunable in thickness from over 1 μm down to less than 20 nm, which corresponds to fewer than 100 water molecules thick. At this thickness, aqueous sheets can readily transmit photons across the spectrum, leading to potentially transformative applications in infrared, X-ray, electron spectroscopies and beyond. The ultrathin sheets are stable for days in vacuum, and we demonstrate their use at free-electron laser and synchrotron light sources.

8 May 2020 in Nature Communications
Verified
Journal Article
Open access
PDF file
RHR. L. Hachadorian
R. L. Hachadorian
PBP. Bruza
P. Bruza
MJM. Jermyn
M. Jermyn
DGD. J. Gladstone
D. J. Gladstone
BPB. W. Pogue
B. W. Pogue
LJL. A. Jarvis
L. A. Jarvis
Imaging Cherenkov emission during radiation therapy cancer treatments can provide a real-time, non-contact sampling of the entire dose field. The emitted Cherenkov signal generated is proportional to deposited dose, however, it is affected by attenuation from the intrinsic tissue optical properties of the patient, which in breast, ranges from primarily adipose to fibroglandular tissue. Patients being treated with whole-breast X-ray radiotherapy (n = 13) were imaged for 108 total fractions, to establish correction factors from the linear relationships between Cherenkov light and CT number (HU). This study elucidates this relationship in vivo, and a correction factor approach is used to scale each image to improve the linear correlation between Cherenkov emission intensity and dose ( $$R_{6X}^2 = 0.85,\,R_{10X}^2 = 0.95$$R6X2=0.85,R10X2=0.95 ). This study provides a major step towards direct quantitative radiation dose imaging in humans by utilizing non-contact camera sensing of Cherenkov emission during the radiation therapy treatment.

13 April 2018 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
BPBrian W. Pogue
Brian W. Pogue
JFJinchao Feng
Jinchao Feng
ELEthan P. LaRochelle
Ethan P. LaRochelle
PBPetr Bruža
Petr Bruža
HLHuiyun Lin
Huiyun Lin
LJLesley A. Jarvis
Lesley A. Jarvis

26 February 2018 in Nature Photonics
Verified
Journal Article
Closed access
PDF file
TGTais Gorkhover
Tais Gorkhover
AUAnatoli Ulmer
Anatoli Ulmer
KFKen Ferguson
Ken Ferguson
MBMax Bucher
Max Bucher
FMFilipe R. N. C. Maia
Filipe R. N. C. Maia
CBChristoph Bostedt
Christoph Bostedt

15 April 2022 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
MAM.Ramish Ashraf
M.Ramish Ashraf
MRMahbubur Rahman
Mahbubur Rahman
XCXu Cao
Xu Cao
KDKayla Duval
Kayla Duval
BWBenjamin B Williams
Benjamin B Williams
PBPetr Bruza
Petr Bruza
Objective. Existing ultra-high dose rate (UHDR) electron sources lack dose rate independent dosimeters and a calibrated dose control system for accurate delivery. In this study, we aim to develop a custom single-pulse dose monitoring and a real-time dose-based control system for a FLASH enabled clinical linear accelerator (Linac). Approach. A commercially available point scintillator detector was coupled to a gated integrating amplifier and a real-time controller for dose monitoring and feedback control loop. The controller was programmed to integrate dose for each radiation pulse and stop the radiation beam when the prescribed dose was delivered. Additionally, the scintillator was mounted in a solid water phantom and placed underneath mice skin for in vivo dose monitoring. The scintillator was characterized in terms of its radiation stability, mean dose-rate ( D ̇ m ), and dose per pulse ( D p ) dependence. Main results. The D p exhibited a consistent ramp-up period across ∼4–5 pulse. The plastic scintillator was shown to be linear with D ̇ m (40–380 Gy s −1 ) and D p (0.3–1.3 Gy Pulse −1 ) to within +/− 3%. However, the plastic scintillator was subject to significant radiation damage (16%/kGy) for the initial 1 kGy and would need to be calibrated frequently. Pulse-counting control was accurately implemented with one-to-one correspondence between the intended and the actual delivered pulses. The dose-based control was sufficient to gate on any pulse of the Linac. In vivo dosimetry monitoring with a 1 cm circular cut-out revealed that during the ramp-up period, the average D p was ∼0.045 ± 0.004 Gy Pulse −1 , whereas after the ramp-up it stabilized at 0.65 ± 0.01 Gy Pulse −1 . Significance. The tools presented in this study can be used to determine the beam parameter space pertinent to the FLASH effect. Additionally, this study is the first instance of real-time dose-based control for a modified Linac at ultra-high dose rates, which provides insight into the tool required for future clinical translation of FLASH-RT.

1 September 2018 in IUCrJ
Verified
Journal Article
Open access
PDF file
ILIda V. Lundholm
Ida V. Lundholm
JSJonas Sellberg
Jonas Sellberg
TETomas Ekeberg
Tomas Ekeberg
MHMax F. Hantke
Max F. Hantke
KOKenta Okamoto
Kenta Okamoto
FMFilipe R. N. C. Maia
Filipe R. N. C. Maia
Diffraction before destruction using X-ray free-electron lasers (XFELs) has the potential to determine radiation-damage-free structures without the need for crystallization. This article presents the three-dimensional reconstruction of the Melbournevirus from single-particle X-ray diffraction patterns collected at the LINAC Coherent Light Source (LCLS) as well as reconstructions from simulated data exploring the consequences of different kinds of experimental sources of noise. The reconstruction from experimental data suffers from a strong artifact in the center of the particle. This could be reproduced with simulated data by adding experimental background to the diffraction patterns. In those simulations, the relative density of the artifact increases linearly with background strength. This suggests that the artifact originates from the Fourier transform of the relatively flat background, concentrating all power in a central feature of limited extent. We support these findings by significantly reducing the artifact through background removal before the phase-retrieval step. Large amounts of blurring in the diffraction patterns were also found to introduce diffuse artifacts, which could easily be mistaken as biologically relevant features. Other sources of noise such as sample heterogeneity and variation of pulse energy did not significantly degrade the quality of the reconstructions. Larger data volumes, made possible by the recent inauguration of high repetition-rate XFELs, allow for increased signal-to-background ratio and provide a way to minimize these artifacts. The anticipated development of three-dimensional Fourier-volume-assembly algorithms which are background aware is an alternative and complementary solution, which maximizes the use of data.