Laura Hellen Cerqueira Gomes dos Santos

Laura Hellen Cerqueira Gomes dos Santos

Auto-generated profile, based on publicly available information

Laura Hellen Cerqueira Gomes dos Santos

Universidade Federal de São Carlos, Departamento de Fisioterapia, São Carlos SP, Brazil

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2022 in Physiotherapy Theory and Practice
Verified
Journal Article
Closed access
LFLisandra Cristine de Faria
Lisandra Cristine de Faria
DMDarlene Barbosa Marques
Darlene Barbosa Marques
LGLaura Hellen dos Santos Cerqueira Gomes
Laura Hellen dos Santos Cerqueira Gomes
SASarah M. dos Anjos
Sarah M. dos Anjos
NDNatalia Duarte
Natalia Duarte
Most measures to assess the lower extremity (LE) after a neurological injury assess the lower limb motor capacity in the laboratory or clinical settings as the lower-extremity motor subscale of Fug...

7 February 2024 in Arquivos de Neuro-Psiquiatria
Verified
Journal Article
Open access
PDF file
NONayara Kelly de Oliveira
Nayara Kelly de Oliveira
LSLaura Helen Cerqueira Gomes dos Santos
Laura Helen Cerqueira Gomes dos Santos
GRGabriela Cristina dos Reis
Gabriela Cristina dos Reis
NDNatalia Duarte
Natalia Duarte
Background StepWatch Activity Monitor (SAM) is used to measure the mobility of chronic hemiparetic patients and the Life Space Assessment (LSA) scale was developed to assess the displacement of hemiparetic patients in different contexts through self-reporting. Studies that apply the LSA remotely and correlate it with the number of steps measured by the SAM were not found. Objective To evaluate the measurement properties of the LSA applied remotely and to evaluate the correlation between the LSA scale score and the number of steps measured by the SAM in post-stroke chronic hemiparetic patients. Methods Nineteen patients participated in the study. The LSA scale was applied remotely and later, face to face. The SAM measured the steps taken by the participants over a period of three consecutive days. The correlation between the LSA and the SAM was performed using Pearson's correlation. The measurement properties calculated of remote LSA were the intraclass correlation coefficient (ICC), Cronbrach's alpha, standard error of measurement (SEM), and smallest real difference (SRD). Results The reproducibility of the LSA scale between remote and face-to-face applications was considered excellent with ICC = 0.85 (IC 95% 0.62-0.94); SEM = 8.4; SRD = 23.2, and Cronbach's alpha = 0.85. The correlation between SAM and LSA was positive, considered moderate (r = 0.51) and significant (p = 0.025). Conclusion The LSA is a reproducible measure for post-stroke chronic hemiparetic patients even if applied remotely and can be used as a remote measurement for mobility in a real-world environment for people with chronic hemiparesis after stroke.

12 May 2026 in Arquivos de Neuro-Psiquiatria
Verified
Journal Article
Open access
LGLaura Hellen S. Cerqueira Gomes
Laura Hellen S. Cerqueira Gomes
DMDarlene Barbosa Marques
Darlene Barbosa Marques
LFLisandra Cristine de Faria
Lisandra Cristine de Faria
GUGitendra Anthony Uswatte
Gitendra Anthony Uswatte
ETEdward Taub
Edward Taub
NDNatalia Duarte
Natalia Duarte
Lower extremity motor function assessments are essential to evaluate mobility and independence in stroke survivors. However, widely-used instruments do not account for the use of assistive devices, which may limit their sensitivity in detecting functional changes over time. To translate and cross-culturally adapt the Lower Extremity Motor Function Test (LE-MFT) into Brazilian Portuguese and to evaluate its initial measurement properties. The present study reports the translation, cross-cultural adaptation, evaluation of internal consistency, interrater reliability, construct validity, and floor/ceiling effects of the LE-MFT Brazil. The LE-MFT was translated and culturally adapted following international guidelines. Fifty stroke survivors were evaluated by two independent raters to examine the interrater reliability. Construct validity was assessed through correlations with the Timed Up and Go (TUG) test and the 10-Meter Walk Test (10MWT). Floor and ceiling effects were also analyzed. All LE-MFT scales showed excellent interrater reliability (intraclass correlation coefficient [ICC] = 0.86–0.96) and internal consistency (Cronbach's Alpha [α] = 0.92–0.96). Strong correlations were found between the LE-MFT and TUG (r ≥ 0.78; p < 0.001), and between the LE-MFT and 10MWT (r ≥ 0.71; p < 0.001), supporting construct validity. No floor nor ceiling effects were observed, except on the Equipment scale, which showed a ceiling effect in 38% of the participants. The Brazilian version of the LE-MFT is a valid and reliable instrument to assess lower-limb motor function in individuals with chronic stroke. Its consideration of assistive-device use provides added clinical value for tracking functional independence.

3 April 2026 in Journal of Bodywork and Movement Therapies
Verified
Journal Article
Open access
GRGabriela Cristina dos Reis
Gabriela Cristina dos Reis
NONayara Kelly de Oliveira
Nayara Kelly de Oliveira
LSLaura Hellen Cerqueira Gomes dos Santos
Laura Hellen Cerqueira Gomes dos Santos
NDNatalia Duarte
Natalia Duarte
Post-stroke hemiparesis commonly reduces mobility, limiting daily activities and participation. Objective monitoring, such as step counting, quantifies real-world ambulatory activity, while patient-reported outcome measures (PROMs) capture perceived functional performance. The Lower Extremity Motor Activity Log (LE-MAL), translated into Portuguese, assesses self-reported use of the more affected lower limb. To examine the criterion-related validity of the LE-MAL by evaluating its association with step counts obtained from triaxial accelerometry activity monitors. In this cross-sectional validation study, 31 individuals with chronic post-stroke hemiparesis wore activity monitors for at least 10 h/day over three consecutive days. The LE-MAL was administered via structured interview. Criterion-related validity was assessed using Pearson's correlation coefficient. Agreement was further explored using the intraclass correlation coefficient (ICC; two-way mixed-effects model, consistency) and Bland-Altman analysis. The LE-MAL total score showed a positive, moderate correlation with the 3-day average step count (r = 0.52, p < 0.01). Agreement between LE-MAL scores and step counts was low (ICC_single = 0.001, 95% CI -0.35 to 0.35; p = 0.497), consistent with conceptual and metric differences between a PROM and an objective activity count. Bland-Altman analysis indicated a mean bias close to zero, wide 95% limits of agreement, and no evidence of proportional bias. The LE-MAL demonstrates a positive, moderate association with objectively measured step counts, supporting its criterion-related validity as a PROM of perceived real-world use of the more affected lower limb. Used alongside activity monitoring, it may help clinicians interpret ambulatory behavior in individuals with chronic post-stroke hemiparesis.

20 May 2025 in Physiotherapy Theory and Practice
Verified
Journal Article
Closed access
LGLaura Hellen S. C. Gomes
Laura Hellen S. C. Gomes
GRGabriela Cristina dos Reis
Gabriela Cristina dos Reis
NONayara Kelley de Oliveira
Nayara Kelley de Oliveira
SASarah M. dos Anjos
Sarah M. dos Anjos
NDNatalia Duarte
Natalia Duarte
The TCI Mobile application (TCI Mobile app) has tools to help assess the mobility of people with chronic stroke. Objective: To investigate the construct validity of the TCI Mobile app to assess the mobility of people with chronic stroke. This cross-sectional study included 30 participants with chronic stroke (>6 months), able to walk 8 meters, three times a day with or without an assistive device. Data collection spans 5 days, starting with sociodemographic data and assessment scales: the Timed Up and Go Test, Life Space Assessment, 6-meter Walk Test, 10-meter Walk Test, and Lower Extremity Motor Activity Log. After baseline data, participants wore the TCI Mobile app and an activity monitor in their homes for 3 consecutive days. The Cohen correlation test was used to assess correlations, categorized as small (0.10-0.29), moderate (0.30-0.49), and large (>0.50). There was a positive and large correlation between the TCI Mobile and activity monitors (0.63 p < .01), 10-meter Walk Test (0.54 p < .01) and Life Space Assessment (0.54 p < .01); a negative and large correlation with the Timed Up and Go Test (-0.50 p < .01); and a positive and moderate correlation with the 6-meter Walk Test (0.42 p = .02) and Lower Extremity Motor Activity Log (0.45 p = .01). The TCI Mobile app demonstrates strong construct validity for assessing mobility in chronic stroke patients. By offering accessible and objective data, it supports clinical decision-making and promotes greater patient engagement in real-world rehabilitation settings.