1 January 1999 in Applied Optics
We have studied the light-scattering properties of human erythrocytes both experimentally and theoretically. In the experimental study measurements were performed with a Scanning Flow Cytometer (SFC). The SFC can measure the light-scattering pattern (indicatrix) of an individual particle over an angular range of 10–60°. We have observed polymorphism in the measured set of indicatrices. To understand the reason for this polymorphism, we have made a theoretical study of the scattering properties of erythrocytes. The Wentzel–Kramer–Brillouin approximation has been employed to calculate indicatrices of individual erythrocytes in different orientations relative to the incident light beam. The indicatrices were calculated over an angular range of 15–35°. A comparison of the experimentally measured and theoretically calculated indicatrices shows that the polymorphism is due mainly to the different orientation of the erythrocytes in the flow. The effect caused by the Poiseuille profile of the flow on an individual erythrocyte within the SFC cuvette capillary was studied theoretically by use of the Stokes approximation. Rotation of an erythrocyte was predicted by this theoretical analysis, and this prediction was further verified by comparison with experimental results.
13 October 1999 in Cytometry
Background: The differential light‐scattering pattern, an indicatrix, provides the most complete characterization of the optical properties of a particle. Particle classification can be performed on the basis of particle parameters retrieved from the indicatrices. This classification extends the ability of flow cytometry in particle recognition. Methods: The scanning flow cytometer (SFC) permits an acquisition of traces of light scattering signals, i.e., native SFC traces, from single particles. The acquired native SFC traces are transformed into indicatrices. The performance of the SFC in measurements of indicatrices has been demonstrated for the following particles: lymphocytes, erythrocytes, polystyrene particles, and milk‐fat particles. Results: The structure and profile of the indicatrix for each particle type have been found to be unique. Classification of polystyrene particles has been performed on the basis of the map formed by particle refractive index and size. The polystyrene particles were classified using this map into different size categories ranging from 1.4–7 μm, with a size deviation of 0.07 μm. Conclusions: The method based on analysis of native SFC traces shows better performance in particle classification than the method based on the particle refractive index and size map. The classification performance of the SFC will be useful, for example, for particle sorting and particle identification, and with additional fluorescent measurements may have applications in multiparameter particle‐based immunoassay. Cytometry 37:215–220, 1999.
9 December 2011 in Vaccine
9 August 2000 in Cytometry
Background Flow cytometry is a powerful tool for the analysis of individual particles in a flow. Differential light scattering (an indicatrix) was used for many years to obtain morphologic information about microorganisms. The indicatrices play the same role for individual particle recognition as a spectrum for substance characterization. We combined two techniques to analyze the indicatrix of the cells for the purpose of developing a database of light‐scattering functions of cells. Methods The scanning flow cytometer (SFC) allows the measurement of the entire indicatrix of individual particles at polar angles ranging from 5° to 100°. In this work, light‐scattering properties of Escherichia coli have been studied both experimentally and theoretically with the SFC and the T‐matrix method, respectively. The T‐matrix method was used because of the nonspherical shape of E. coli cells, which were modeled by a prolate spheroid. Results The indicatrices of E. coli cells were stimulated with T‐matrix method at polar angles ranging from 10° to 60°. The absolute cross‐section of light scattering of E. coli has been determined comparing the cross section of polystyrene particles modeled by a homogeneous sphere. The E. coli indicatrices were compared for logarithmic and stationary phases of cell growth. Conclusions The indicatrices of E. coli were reproducible and could be used for identification of these cells in biologic suspensions. The angular location of the indicatrix minimum can be used in separation of cells in logarithmic and stationary phases. To use effectively the indicatrices for that purpose, the light‐scattering properties of other microorganisms have to be studied. Cytometry 41:41–45, 2000
1 November 2006 in Journal of Quantitative Spectroscopy and Radiative Transfer