1 June 2021 in Psychological Assessment
This study aims to examine whether there is an equivalence between the two different versions of Wisconsin Card Sorting Test (WCST) regarding psychometric properties on two distinct samples: individuals diagnosed with schizophrenia and those who are healthy. A total of 504 individuals were included in the study, 243 were diagnosed with schizophrenia, and 261 were healthy individuals. Both samples were separated into two subsamples, and the individuals in each separated group were administered either WCST-C (computerized) or WCST-M (manual) version of the test. We compared statistical measures of mean and variance with the data obtained from the two samples. We carried out analyses related to parallel forms reliability and equality of variances of the tests scores produced by parallel forms of the WCST. There was no significant difference between mean values of manual and computerized versions administered for each sample. However, the patterns of variances of the obtained scores were dissimilar. According to these findings, the two versions were found to be inequivalent regarding psychometric properties. (PsycInfo Database Record (c) 2021 APA, all rights reserved).
1 May 2018 in Biomedical Signal Processing and Control
1 January 2023 in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
Image segmentation, whose objectives are set by well-defined tasks and which is generally significant for automatic applications, deals with isolating image pixels of interest. Data; which might be redundant, useless or even task-complicating due to amount and rawness, must be reduced, compact representations must be obtained and useful features must be extracted. In this work, a heuristic approach for detecting skull contours in monochrome ultrasound images displaying transcerebellar fetal skulls is described. At the start of the process, the user is expected to mark few points manually along the skull boundary on the input image. Due to the bright-pixels composition of skull contours and discontinuities between edge segments arising from imaging modality, the heuristic method utilizes the concepts of average shape model and intensity-based computation of average positions. The results on sample images, when compared to ground-truth segmentations, indicate a 96,5% similarity on average. When the visually-satisfactory outputs are used as inputs in diagnosis systems for spina bifida detection, either better or comparable results are obtained in terms of F-measure and GMRP. The proposed method is supposed to be a facilitative factor in certain automatic diagnosis systems.