Peng Wu

Peng Wu

Auto-generated profile, based on publicly available information

Peng Wu

Electric Power Wireless Communication Technology Laboratory, China Electric Power Research Institute, Nanjing, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JWJunmin Wu
Junmin Wu
PWPeng Wu
Peng Wu
SLShidong Liu
Shidong Liu
XWXiaoli Wang
Xiaoli Wang
YXYaqin Xie
Yaqin Xie
The high-accuracy self-positioning of the inspection robot is the key to ensure the accuracy of the inspection task. The existing location solutions do not solve the problem of low positioning accuracy when the robot is located at the edge of the cell. The positioning method based on received signal strength (RSS) is a low-cost positioning scheme. However, this method is greatly affected by the fluctuation of the RSS, which leads to the poor positioning accuracy of the target, especially for the target located at the edge of the cell. Meanwhile, the positioning accuracy is also related to the location distribution of the access point (AP). A three-step optimization algorithm based on RSS and AP layout is proposed in this article to improve the localization accuracy of the inspection robots when it is at the edge of the cell. First, the optimal AP layout with the highest positioning accuracy is selected based on the maximization of Fisher information matrix (FIM). Then, the matrix is decomposed based on the active set method (ASM). Finally, for different initial user estimation position, the positioning accuracy of the user is further improved using an improved extended min-max (IEMM) method. Simulation results show that the optimal AP layout ensures the lowest positioning error compared with the specified and the worst layout scenario. In the case of six optimal AP layouts, the positioning accuracy of the proposed algorithm is improved by 16.07%, 48.35%, and 17.54% compared with the min-max strategy (MMS), the min-max (MM) algorithm with area partition strategy, and the traditional Taylor series expansion method, respectively.

18 October 2024
Verified
Conference Paper
Open access
MSMinda Shi
Minda Shi
BRBaoping Ren
Baoping Ren
LZLiang Zhu
Liang Zhu
PWPeng Wu
Peng Wu
WJWei Jiang
Wei Jiang
In this paper, we employ the cloud-radio access network (C-RAN) architecture to support the electricity sensors (ESs) with ultra-reliable and low-latency communication (URLLC) requirements in smart grids. Our study specifically addresses scenarios involving unlicensed spectrum and imperfect channel knowledge, with a focus on evaluating the ESs’ rate performance under listen-before-talk (LST) operations. Utilizing the use-and-then-forget bounding technique in conjunction with finite blocklength capacity theory, we derive a closed-form expression for the achievable rate. This expression facilitates a comprehensive analysis of the impact of LBT across various system configurations. The theoretical findings are validated through extensive simulations, providing significant insights into the performance of ESs in the considered C-RAN-URLLC framework.