David G Sutton

David G Sutton

Auto-generated profile, based on publicly available information

David G Sutton

Department of Medical Physics, University of Dundee, UK

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2012 in Journal of Radiological Protection
Verified
Journal Article
Closed access
HWH Wallace
H Wallace
CMC J Martin
C J Martin
DSD G Sutton
D G Sutton
DPD Peet
D Peet
JWJ R Williams
J R Williams
The specification of shielding for CT facilities in the UK and many other countries has been based on isodose scatter curves supplied by the manufacturers combined with the scanner's mAs workload. Shielding calculations for radiography and fluoroscopy are linked to a dose measurement of radiation incident on the patient called the kerma-area product (KAP), and a related quantity, the dose-length product (DLP), is now employed for assessment of CT patient doses. In this study the link between scatter air kerma and DLP has been investigated for CT scanners from different manufacturers. Scatter air kerma values have been measured and scatter factors established that can be used to estimate air kerma levels within CT scanning rooms. Factors recommended to derive the scatter air kerma at 1 m from the isocentre are 0.36 µGy (mGy cm)(-1) for the body and 0.14 µGy (mGy cm)(-1) for head scans. The CT scanner gantries only transmit 10% of the scatter air kerma level and this can also be taken into account when designing protection. The factors can be used to predict scatter air kerma levels within a scanner room that might be used in risk assessments relating to personnel whose presence may be required during CT fluoroscopy procedures.

3 May 2012 in Journal of Radiological Protection
Verified
Journal Article
Closed access
DSD G Sutton
D G Sutton
CMC J Martin
C J Martin
DPD Peet
D Peet
JWJ R Williams
J R Williams
The specification of shielding for fluoroscopic facilities in the UK is based on the determination of scatter incident on a barrier using a simple formula linking kerma area product and scatter kerma. Over the last few years there has been a move to incorporate additional copper filtration in equipment used for high dose fluoroscopic and interventional examinations, and the existing formula does not take this into account. The spectral and transmission characteristics of the scattered radiation resulting from a primary x-ray beam filtered with additional copper are not known. In this study, the relationship between primary and scattered radiation in these beams has been investigated as have their transmission characteristics. The scatter kerma area product from filtered beams is shown to be greater than that from conventional x-rays and a simple numerical correction linking the two has been derived. The implications for shielding calculations have been assessed and the impact of the correction on calculated barrier thickness has been shown to be relatively small. The broad beam transmission characteristics of the radiation scattered from the filtered beams have been simulated using Monte Carlo methods and found to be adequately described by the standard transmission equation using conventional coefficients.

1 September 2014 in British Journal of Radiology
Verified
Journal Article
Open access
DSD G Sutton
D G Sutton
SMS McVey
S McVey
DGD Gentle
D Gentle
AHA J Hince
A J Hince
NMNicola MacDonald
Nicola MacDonald
SMS McCallum
S McCallum
This article reports on a pilot study designed to collect dose data representative of current CT chest abdomen pelvis (CAP) practice in Scotland, make any immediately obvious interventions and to identify if the current UK diagnostic reference level (DRL) of 940 mGy cm is still appropriate. The aims are to identify if a Scotland-wide picture archiving and communication system (PACS)-based dose audit of a number of CT examinations is likely to have value in terms of optimization of patient doses and to comment on the significance of the results in terms of future optimization strategies. Dose audit of CT CAP examinations at 32 different scanner sites across Scotland using accepted data collection and analysis methods. The minimum sample size was 30. RESULTS indicate that CT CAP doses are lower than those previously reported (median, 800 mGy cm, 75th percentile 840 mGy cm) but follow a distribution that is not in keeping with the concept of DRLs as presently understood or implemented. There is value in a PACS-based dose audit project to provide serial snapshots of patient doses as optimization efforts take place and to revise current knowledge about CT doses. In our opinion, the results call into question whether DRLs or the concept of "achievable dose" are suitable for devising optimization strategies once a certain degree of optimization has taken place. The results reported here suggest that it may be time to take a different approach to optimization, concentrating on tools that are more refined than the DRL, which may have become more of a compliance tool than an aid to optimization.

1 August 1993 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
DSD G Sutton
D G Sutton
VKV Kempi
V Kempi

9 September 2025 in Journal of Radiological Protection
Verified
Journal Article
Open access
WRW. Rühm
W. Rühm
KAK. Applegate
K. Applegate
NBN. Ban
N. Ban
FBF. Bochud
F. Bochud
SBSimon Bouffler
Simon Bouffler
AWAndrzej Wojcik
Andrzej Wojcik
The System of Radiological Protection (the “System”) developed by the International Commission on Radiological Protection (ICRP) is built on nearly a century of efforts of numerous scientists and practitioners working together internationally. It rests on three enduring pillars: science, ethics, and experience. These pillars support the three fundamental principles that shape radiological protection strategies: justification, optimisation, and application of dose limits. Of note, optimisation of protection must be understood as a flexible and context-sensitive process, which allows identification of the appropriate level of protection, not simply the lowest dose, taking into account economic, societal and environmental factors. The System has proven effective in protecting workers, patients, members of the public, and the environment in all exposure situations. Effects of high doses, where acute injuries to healthy tissue occur, are rarely observed, and mostly due to accidental situations except for unavoidable side effects of radiotherapy. At low doses, the System is supported by application of the Linear-No-Threshold (LNT) model. This model enables prudent (that is, carefully considered given existing uncertainties) policy decisions and estimation of risks at low doses by extrapolation from epidemiological data observed at medium and high radiation doses, acknowledging uncertainty without ignoring potential harm.

17 October 2024 in Journal of Radiological Protection
Verified
Journal Article
Open access
JHJohn D Harrison
John D Harrison
Mark HillMark Hill
Mark Hill
SMSusan McCready-Shea
Susan McCready-Shea
GSGraham M Smith
Graham M Smith
DSDavid G Sutton
David G Sutton
The term ‘low dose’ is applied to different levels of dose depending on the circumstances of exposure, with the potential for confusion unless the reasoning is clear. The United Nations Scientific Committee on the Effects of Ionising Radiation has defined low absorbed doses of ionising radiation as below about 100 mGy, and low dose rates as below 0.1 mGy min−1 (6 mGy h−1). These values relate to the interpretation of scientific evidence from epidemiological and biological studies. The International Commission on Radiological Protection has used similar values of 100 mSv and 5 mSv h−1 and applied this categorisation directly to the specific situation of patients undergoing diagnostic procedures: doses below 100 mSv were referred to as ‘low’ and doses below 10 mSv as ‘very low’. Consideration of other exposure situations suggest that the same terms can be used for exposures received by emergency workers. However, for workers and members of the public in planned exposure situations, it is suggested that the term ‘low dose’ applies to doses below 10 mSv and 1 mSv, respectively—that is, below the dose limits. In each case, dose is being used as a surrogate for risk—risks at low doses are uncertain and estimates may change, but order of magnitude considerations are sufficient in most cases. Doses of < 100 mSv, < 10 mSv and < 1 mSv correspond to life-time cancer risk estimates of the order of < 10−2, < 10−3 and < 10−4, respectively.