12 May 2020 in IEEE Access
Doubly fed induction generator (DFIG) may suffer from huge disturbance owing to the uncertainty of generator parameters and load fluctuation during operation process. Hence, in the context of virtual synchronous generator (VSG) technology and its power-frequency control characteristics, this paper presents a VSG-based nonlinear adaptive robust controller (NARC), aiming to enhance the comprehensive regulation performance of DFIG. Firstly, a nonlinear robust adaptive controller with disturbance rejection and uncertainty adaptive learning ability is designed by establishing an improved dynamic model of the rotor motion equation in VSG, so as to achieve the optimal regulation of DFIG with robustness and adaptability. Secondly, in order to realize the fast dynamic response and autonomous synchronization ability in DFIG, a modified control strategy of the grid side converter (GSC) in DFIG is constructed by voltage and current dual-loop control (DLC) and VSG, which not only retains the significant dynamic response ability of the current inner-loop in DLC, but also improves the inertia and damping of the system. Finally, simulation results indicate that the modified control strategy exhibits satisfied dynamic performance and reliability, and reveals the robustness and adaptability of the control strategy in response to external random interferences and internal uncertain parameters.
1 January 2025 in IET Generation, Transmission & Distribution
Aiming at the problem of increased complexity in broadband oscillations caused by the introduction of virtual synchronous generator (VSG) control to grid‐forming and grid‐following grid‐connected converters interacting with inductive weak grids, positive and negative sequence impedance of such converters is established under small perturbations in phase angle and voltage using harmonic linearization. The impact of various control links on the broadband impedance characteristics associated with different control strategies is then analysed. It is observed that the grid‐forming converter equipped with VSG demonstrates lower impedance magnitude and inductive behaviour in the medium‐to‐high frequency range, thus emulating the external behaviour of a synchronous generator more accurately. Furthermore, the analysis based on the maximum peak Nyquist stability criterion reveals that voltage control and current‐type VSG lack phase margin, leading to potential oscillation risks within their respective dominant frequency bands. Finally, the validity of the broadband oscillation mechanism analysis is confirmed through hardware‐in‐loop experiments and impedance sweep analyses.
23 July 2025 in Journal of Power Sources
1 August 2021 in Surfaces and Interfaces
1 January 2026 in IET Image Processing
This paper introduces MEA‐YOLO, a robust and efficient detector evolved from YOLOv8n, aimed at achieving an optimal balance between detection accuracy and computational cost in challenging transmission‐line environments: (1) a MAF‐Enchancer module that amalgamates receptive‐field attention convolution (RFA‐Conv), progressive multi‐scale feature refinement and a content‐driven enhancement block to augment feature extraction in instances of substantial degradation; (2) a SENetV2‐based dynamic channel attention technique to accentuate defect‐related representations while mitigating background noise; A dynamic drenching and bifurcation detection mechanism to improve multi‐scale feature modelling while ensuring efficient inference. To assess the suggested methodology, we create a transmission‐line defect dataset encompassing various environmental circumstances and subsequently validate the model on an additional industrial defect dataset to evaluate model generalisability. The experimental findings indicate that MEA‐YOLO attains a mean Average Precision (mAP) of 0.8031 across five demanding scenarios, surpassing the YOLOv8n baseline by 0.0502. Ultimately, thorough comparisons with traditional detectors, current YOLO benchmarks, lightweight alternatives and state‐of‐the‐art transformer‐based real‐time detectors reveal that MEA‐YOLO attains an ideal equilibrium among robustness, accuracy and computational efficiency, validating its practical applicability for real‐world transmission‐line inspection contexts.
6 August 2025 in International Journal of Circuit Theory and Applications