Haishuang Hao

Haishuang Hao

Auto-generated profile, based on publicly available information

Haishuang Hao

School of Chinese Materia Medica, Nanjing University of Chinese Medicine, Nanjing, 210023, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2024 in Journal of Ethnopharmacology
Verified
Journal Article
Closed access
LWLong Wang
Long Wang
HHHaishuang Hao
Haishuang Hao
XMXian-Hua Meng
Xian-Hua Meng
WZWenbo Zhang
Wenbo Zhang
YZYin Zhang
Yin Zhang
JYJunli Yang
Junli Yang

17 August 2021 in Zhonghua Yi Xue Za Zhi
Verified
Journal Article
Closed access
XLX N Liu
X N Liu
XCX J Chen
X J Chen
XSX B Sun
X B Sun
WQWei Qiu
Wei Qiu
LPL S Peng
L S Peng
HHH J Hao
H J Hao
Objective: To establish the standard operation procedure (SOP) for detection of oligoclonal band (OCB) in cerebrospinal fluid (CSF) and verify consistency by using this SOP in different laboratories. Methods: The SOP for detection of CSF-OCB fluid was successfully established by an expert feedback approach. Neuroimmunology laboratories in 3 representative Chinese three-tier research hospitals were selected for this study, and commercially available protein electrophoresis automation systems and detection SOP were set up. The quality control product was provided by the College of American Pathologists (CAP) and Sebiacompany were used for interior quality and compared to each other, respectively. Seventeen serum and CSF paired samples were tested and compared using the same SOP. Kappa test or Kendall W test were adopted to evaluate the inter-laboratory consistency among different hospitals. Results: The results of repeated testings in a single hospital suggested that the 2-and 4-fold dilution for CSF-OCB were reported as positive, while 64-and 128-fold dilution were reported as negative. Positive or negative inconsistencies were reported in 8-, 16-, and 32-fold dilution. After increasing the number of repetitions, the results showed that both 16-and 32-fold dilution were reported as negative, and 8-fold dilution exhibited negative results (2 positive results for 40 repetitions, coincidence rate=95%).The results of multi-center inter-laboratory quality assessment showed that the detection consistency rate among 3 hospitals was 100% (Kappa value =1). Conclusions: The SOP to detect CSF-OCB established in this study demonstrates a good repeatability and stability. Therefore,such SOP would be a good reference for diagnostic laboratories to detect CSF-OCB in China.