Gleb M. Katyba

Gleb M. Katyba

Auto-generated profile, based on publicly available information

Gleb M. Katyba

Osipyan Institute of Solid State Physics of the Russian Academy of Sciences, Chernogolovka, Russia

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2018 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
NCNikita Chernomyrdin
Nikita Chernomyrdin
AKA. S. Kucheryavenko
A. S. Kucheryavenko
GKG. S. Kolontaeva
G. S. Kolontaeva
GKG. M. Katyba
G. M. Katyba
IDIrina Dolganova
Irina Dolganova
KZKirill I. Zaytsev
Kirill I. Zaytsev
We have developed a method of terahertz (THz) solid immersion (SI) microscopy for continuous-wave reflection-mode imaging of soft biological tissues with a sub-wavelength spatial resolution. In order to achieve strong reduction in the dimensions of the THz beam caustic, an electromagnetic wave is focused into the evanescent field volume behind a medium with a high refractive index. We have experimentally demonstrated a 0.15λ-resolution of the proposed imaging modality at λ = 500 μm, which is beyond the Abbe diffraction limit and represents a considerable improvement over the previously-reported arrangements of SI imaging setups. The proposed technique does not involve any sub-wavelength near-field probes and diaphragms, thus, avoiding the THz beam attenuation due to such elements. We have applied the developed method for THz imaging of various soft tissues: a plant leaf blade, cell spheroids, and tissues of the breast ex vivo. Our THz images clearly reveal sub-wavelength features in tissues, therefore, promising applications of THz SI microscopy in biology and medicine.

1 December 2018 in Progress in Crystal Growth and Characterization of Materials
Verified
Journal Article
Closed access
GKG.M. Katyba
G.M. Katyba
KZK.I. Zaytsev
K.I. Zaytsev
IDIrina Dolganova
Irina Dolganova
ISI.A. Shikunova
I.A. Shikunova
NCNikita Chernomyrdin
Nikita Chernomyrdin
VKVladimir Kurlov
Vladimir Kurlov

6 February 2019 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
AGArseniy A. Gavdush
Arseniy A. Gavdush
NCNikita Chernomyrdin
Nikita Chernomyrdin
KMKirill M. Malakhov
Kirill M. Malakhov
SBSheyh-Islyam T. Beshplav
Sheyh-Islyam T. Beshplav
IDIrina Dolganova
Irina Dolganova
KZKirill I. Zaytsev
Kirill I. Zaytsev
We applied terahertz (THz)-pulsed spectroscopy to study ex vivo the refractive index and absorption coefficient of human brain gliomas featuring different grades, as well as perifocal regions containing both intact and edematous tissues. Glioma samples from 26 patients were considered and analyzed according to further histological examination. In order to fix tissues for the THz measurements, we applied gelatin embedding, which allows for sustaining their THz response unaltered, as compared to that of the freshly excised tissues. We observed a statistical difference between the THz optical constants of intact tissues and gliomas of grades I to IV, while the response of edema was similar to that of tumor. The results of this paper justify a potential of THz technology in the intraoperative label-free diagnosis of human brain gliomas for ensuring the gross-total resection.

6 September 2018 in Advanced Optical Materials
Verified
Journal Article
Closed access
PDF file
GKGleb M. Katyba
Gleb M. Katyba
KZKirill I. Zaytsev
Kirill I. Zaytsev
NCNikita Chernomyrdin
Nikita Chernomyrdin
ISIrina A. Shikunova
Irina A. Shikunova
GKGennady A. Komandin
Gennady A. Komandin
MSMaksim Skorobogatiy
Maksim Skorobogatiy

18 May 2016 in IEEE Transactions on Terahertz Science and Technology
Verified
Journal Article
Closed access
KZKirill I. Zaytsev
Kirill I. Zaytsev
GKGleb M. Katyba
Gleb M. Katyba
VKVladimir Kurlov
Vladimir Kurlov
ISIrina A. Shikunova
Irina A. Shikunova
VKValeriy E. Karasik
Valeriy E. Karasik
SYStanislav O. Yurchenko
Stanislav O. Yurchenko
In this paper, an ability for highly efficient terahertz (THz) waveguiding in multichannel sapphire shaped crystals is demonstrated. The edge-defined film-fed growth (EFG) technique (or Stepanov technique) of shaped crystal growth has been implemented to manufacture the THz photonic crystalline (PC) waveguide. The PC waveguide has been characterized using both numerical simulations and experimental study. It allows guiding the THz waves in multimode regime with the minimal dispersion in frequency range of 1.0-1.55 THz and the minimal power extinction coefficient of 0.02 dB/cm at 1.45 THz. The mode interference phenomenon has been observed in this waveguide highlighting the prospectives of its use for intrawaveguide interferometry. These results demonstrate the capabilities of combining the EFG/Stepanov technique advantages with unique properties of sapphire, such as relatively low THz-wave absorption, high mechanical, thermal, chemical, and radiation strength, for manufacturing the THz waveguides characterized with low loss and dispersion and suitable for use in wide range of THz technology applications in biomedical and material sciences, including sensing in aggressive environment.

11 November 2021 in Optica
Verified
Journal Article
Open access
NCNikita Chernomyrdin
Nikita Chernomyrdin
MSMaksim Skorobogatiy
Maksim Skorobogatiy
AGArsenii Gavdush
Arsenii Gavdush
GMG. R. Musina
G. R. Musina
GKG. M. Katyba
G. M. Katyba
KZKirill I. Zaytsev
Kirill I. Zaytsev
Solid Immersion (SI) microscopy is a modern imaging modality that overcomes the Abbe diffraction limit and offers novel applications in various branches of visible, infrared, terahertz, and millimeter-wave optics. Despite the widespread use, SI microscopy usually results in qualitative imaging. Indeed, it presents only the raw distributions (in the image plane) of the backscattered field intensity, while unlocking the information about the physical properties of an imaged object, such as its complex refractive index (RI) distribution, requires resolving the inverse problem and remains a daunting task. In this paper, a method for resolving the SI microscopy inverse problem is developed, capable of reconstructing the RI distribution at the object imaging plane with subwavelength spatial resolution, while performing only intensity measurements. The sample RI is retrieved via minimization of the error function that characterizes discrepancy between the experimental data and the predictions of analytical model. This model incorporates all the key features of the electromagnetic-wave interaction with the SI lens and an imaged object, including contributions of the evanescent and ordinary-reflected waves, as well as effects of light polarization and wide beam aperture. The model is verified numerically, using the finite-element frequency-domain method, and experimentally, using the in-house reflection-mode continuous-wave terahertz SI microscope. Spatial distributions of the terahertz RIs of different low-absorbing optical materials and highly absorbing biological objects were studied and compared to a priori known data to demonstrate the potential of the novel SI microscopy modality. Given the linear nature of the Maxwell’s equations, the developed method can be applied for subwavelength-resolution SI microscopy at other spectral ranges.