Pablo D. Quinones

Pablo D. Quinones

Auto-generated profile, based on publicly available information

Pablo D. Quinones

Department of Mechanical Engineering, University of Michigan-Ann Arbor, Ann Arbor, MI 48105

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2005 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
NDNihad Dukhan
Nihad Dukhan
PQPablo D. Quiñones-Ramos
Pablo D. Quiñones-Ramos
ECEdmundo Cruz-Ruiz
Edmundo Cruz-Ruiz
Miguel Velez-ReyesMiguel Velez-Reyes
Miguel Velez-Reyes
ESElaine P. Scott
Elaine P. Scott

1 January 2012 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
PQPablo D. Quiñones
Pablo D. Quiñones
GCGerardo J. Carbajal
Gerardo J. Carbajal

14 July 2009 in Journal of Electronic Packaging
Verified
Journal Article
Closed access
PDF file
PQPablo D. Quinones
Pablo D. Quinones
LMLawrence S. Mok
Lawrence S. Mok
A cooling device using stacked centrifugal fans and circular heat sinks was designed for cooling a semiconductor chip with a heat flux near 125 W/cm2. In this device, heat is conducted from the chip to a copper heat distribution block and then distributed to multiple heat sinks via four heat pipes. The copper block with embedded heat pipes or evaporator block was optimized using finite element analysis, and several cases were validated with experimental data. The experiments showed great benefits by having a second fan/heat sink in the device. The copper block by itself was found to contribute more than half of the overall thermal resistance of the cooling device. The thermal spreading resistance of the block can be reduced by about 70% if a piece of high-conductivity material, such as a diamond-copper composite, is inserted into its base. The thermal spreading resistance is generally lower when the thickness of the high-conductivity base piece increases. However, the analysis shows that the benefit of using a high-conductivity base tapers off as the thickness of the base piece nears the diameter of the heat pipes (δ∗=1) and weakly worsens after (δ∗>1). The base will also not have a benefit when the size of the chip approaches that of the copper block (A∗=1).

1 January 2003
Verified
Conference Paper
Closed access
PDF file
YJYi Jia
Yi Jia
PQPablo D. Quinones
Pablo D. Quinones
Frictional heating from rolling and sliding contacts of gear teeth is of extreme importance for monitoring the health of a gear transmission under its continuing operation. The surface temperature holds the critical information about a gear’s health condition. A new power circulating gear test rig with a multichannel computer data acquisition system has been built to develop various sensor technologies for surface temperature evaluation of gear teeth. In this paper, the surface temperature monitoring of gear tooth will be presented by using miniature thermocouples. Five miniature type-K thermocouples of 125 μm in diameter have been embedded underneath the tooth surface of a spur gear, and real-time surface temperature variations from a wide range of operating conditions were measured. The various effects of load, rotating speed, and meshing point on the surface temperature are discussed. The results attained in this study indicate that the maximum temperature rise occurs on the dedendum, close to the dedendum circle, and the maximum surface temperature difference at the various contact points along the tooth profile was 13°C. Among the various temperature monitoring techniques, the thermocouple is a very reliable and practical mean for gear health monitoring.