Ana Cláudia Mirândola Barbosa Reis

Ana Cláudia Mirândola Barbosa Reis

Auto-generated profile, based on publicly available information

Ana Cláudia Mirândola Barbosa Reis

Universidade de São Paulo, Brasil

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2015 in Brazilian Journal of Otorhinolaryngology
Verified
Journal Article
Open access
ARAna Cláudia Mirandola Barbosa Reis
Ana Cláudia Mirandola Barbosa Reis
AFAna Claudia Figueiredo Frizzo
Ana Claudia Figueiredo Frizzo
MIMyriam de Lima Isaac
Myriam de Lima Isaac
CGCristiane Fregonesi Dutra Garcia
Cristiane Fregonesi Dutra Garcia
CFCarolina Araújo Rodrigues Funayama
Carolina Araújo Rodrigues Funayama
MIMaria Cecília Martinelli Iório
Maria Cecília Martinelli Iório
Behavioral and electrophysiological auditory evaluations contribute to the understanding of the auditory system and of the process of intervention. To study P300 in subjects with severe or profound sensorineural hearing loss. This was a descriptive cross-sectional prospective study. It included 29 individuals of both genders with severe or profound sensorineural hearing loss without other type of disorders, aged 11 to 42 years; all were assessed by behavioral audiological evaluation and auditory evoked potentials. A recording of the P3 wave was obtained in 17 individuals, with a mean latency of 326.97ms and mean amplitude of 3.76V. There were significant differences in latency in relation to age and in amplitude according to degree of hearing loss. There was a statistically significant association of the P300 results with the degrees of hearing loss (p=0.04), with the predominant auditory communication channels (p<0.0001), and with time of hearing loss. P300 can be recorded in individuals with severe and profound congenital sensorineural hearing loss; it may contribute to the understanding of cortical development and is a good predictor of the early intervention outcome.

1 May 2019 in Brazilian Journal of Otorhinolaryngology
Verified
Journal Article
Open access
MAMaria Stella Arantes Do Amaral
Maria Stella Arantes Do Amaral
ARAna Cláudia Mirândola B. Reis
Ana Cláudia Mirândola B. Reis
EMEduardo T. Massuda
Eduardo T. Massuda
MHMiguel Hyppolito
Miguel Hyppolito
The surgery during which the cochlear implant internal device is implanted is not entirely free of risks and may produce problems that will require revision surgeries. To verify the indications for cochlear implantation revision surgery for the cochlear implant internal device, its effectiveness and its correlation with certain variables related to language and hearing. A retrospective study of patients under 18 years submitted to cochlear implant surgery from 2004 to 2015 in a public hospital in Brazil. Data collected were: age at the time of implantation, gender, etiology of the hearing loss, audiological and oral language characteristics of each patient before and after cochlear implant surgery and any need for surgical revision and the reason for it. Two hundred and sixty-five surgeries were performed in 236 patients. Eight patients received a bilateral cochlear implant and 10 patients required revision surgery. Thirty-two surgeries were necessary for these 10 children (1 bilateral cochlear implant), of which 21 were revision surgeries. In 2 children, cochlear implant removal was necessary, without reimplantation, one with cochlear malformation due to incomplete partition type I and another due to trauma. With respect to the cause for revision surgery, of the 8 children who were successfully reimplanted, four had cochlear calcification following meningitis, one followed trauma, one exhibited a facial nerve malformation, one experienced a failure of the cochlear implant internal device and one revision surgery was necessary because the electrode was twisted. The incidence of the cochlear implant revision surgery was 4.23%. The period following the revision surgeries revealed an improvement in the subject's hearing and language performance, indicating that these surgeries are valid in most cases.

3 July 2016 in International Archives of Otorhinolaryngology
Verified
Journal Article
Open access
PDF file
GCGrace Kelly Seixas Ciscare
Grace Kelly Seixas Ciscare
EMErika Barioni Mantello
Erika Barioni Mantello
CFCarla Aparecida Urzedo Fortunato-Queiroz
Carla Aparecida Urzedo Fortunato-Queiroz
MHMiguel Hyppolito
Miguel Hyppolito
ARAna Reis
Ana Reis
Introduction A cochlear implant in adolescent patients with pre-lingual deafness is still a debatable issue. Objective The objective of this study is to analyze and compare the development of auditory speech perception in children with pre-lingual auditory impairment submitted to cochlear implant, in different age groups in the first year after implantation. Method This is a retrospective study, documentary research, in which we analyzed 78 reports of children with severe bilateral sensorineural hearing loss, unilateral cochlear implant users of both sexes. They were divided into three groups: G1, 22 infants aged less than 42 months; G2, 28 infants aged between 43 to 83 months; and G3, 28 older than 84 months. We collected medical record data to characterize the patients, auditory thresholds with cochlear implants, assessment of speech perception, and auditory skills. Results There was no statistical difference in the association of the results among groups G1, G2, and G3 with sex, caregiver education level, city of residence, and speech perception level. There was a moderate correlation between age and hearing aid use time, age and cochlear implants use time. There was a strong correlation between age and the age cochlear implants was performed, hearing aid use time and age CI was performed. Conclusion There was no statistical difference in the speech perception in relation to the patient's age when cochlear implant was performed. There were statistically significant differences for the variables of auditory deprivation time between G3 - G1 and G2 - G1 and hearing aid use time between G3 - G2 and G3 - G1.

1 August 2016 in CoDAS
Verified
Journal Article
Open access
HSHumberto de Oliveira Simões
Humberto de Oliveira Simões
AFAna Cláudia Figueiredo Frizzo
Ana Cláudia Figueiredo Frizzo
SZSthella Zanchetta
Sthella Zanchetta
MHMiguel Hyppolito
Miguel Hyppolito
ARAna Cláudia Mirândola Barbosa Reis
Ana Cláudia Mirândola Barbosa Reis
To analyze the latency and amplitude of P300 responses obtained with electrodes positioned at Cz and Fz and in different tasks of infrequent stimulus identification in normal hearing individuals. Forty adults of both genders participated in the study. Three recordings with three different tasks were obtained for the identification of the infrequent stimulus; simultaneous recordings were obtained from Cz and Fz positions. Cz position showed significantly greater amplitudes and lower latencies than Fz. Regarding the three tasks, only "pronouncing the word 'thin'" was different from "raising a finger", with lowest latencies for the verbal task. Regarding amplitude, significantly higher values were observed for "raising a finger", followed by "pronouncing the word 'thin'" and mental counting. Cz obtained the best values, highest amplitude and lowest latency. Lowest latencies were obtained for the task of "pronouncing the word 'thin'" and the highest amplitudes were obtained for "raising a finger".

12 July 2015 in International Archives of Otorhinolaryngology
Verified
Journal Article
Open access
PDF file
ABAline Cristine Bazon
Aline Cristine Bazon
AGAlina Sanches Gonçales
Alina Sanches Gonçales
MIMyriam de Lima Isaac
Myriam de Lima Isaac
MHMiguel Hyppolito
Miguel Hyppolito
ARAna Cláudia Mirândola Barbosa Reis
Ana Cláudia Mirândola Barbosa Reis
EMErika Barioni Mantello
Erika Barioni Mantello
Introduction The objective of the evaluation of auditory perception of cochlear implant users is to determine how the acoustic signal is processed, leading to the recognition and understanding of sound. Objective To investigate the differences in the process of auditory speech perception in individuals with postlingual hearing loss wearing a cochlear implant, using two different speech coding strategies, and to analyze speech perception and handicap perception in relation to the strategy used. Methods This study is prospective cross-sectional cohort study of a descriptive character. We selected ten cochlear implant users that were characterized by hearing threshold by the application of speech perception tests and of the Hearing Handicap Inventory for Adults. Results There was no significant difference when comparing the variables subject age, age at acquisition of hearing loss, etiology, time of hearing deprivation, time of cochlear implant use and mean hearing threshold with the cochlear implant with the shift in speech coding strategy. There was no relationship between lack of handicap perception and improvement in speech perception in both speech coding strategies used. Conclusion There was no significant difference between the strategies evaluated and no relation was observed between them and the variables studied.

1 January 2020 in Brazilian Journal of Otorhinolaryngology
Verified
Journal Article
Open access
SZSthella Zanchetta
Sthella Zanchetta
HSHumberto Oliveira Simões
Humberto Oliveira Simões
PLPamela Papile Lunardelo
Pamela Papile Lunardelo
MCMarina de Oliveira Canavezi
Marina de Oliveira Canavezi
ARAna Cláudia Mirândola Barbosa Reis
Ana Cláudia Mirândola Barbosa Reis
EMEduardo Tanaka Massuda
Eduardo Tanaka Massuda
Patient-reported outcome measures, inventory and or questionnaire, allow patients to present their perspective of the impact of their individual condition on a day-to-day basis, independent of the analysis of test results by the expert clinician. Outcome measures are recommended when there is evidence showing their reliability, validity and sensitivity. There are standardized patient-reported outcome measures for hearing in English language; however, other languages lack these instruments. Adapt the Amsterdam inventory for auditory disability and handicap to Brazilian Portuguese and analyze its validation measures. We conducted two studies. In Study 1, we translated and adapted the Amsterdam inventory for auditory disability and handicap to Brazilian Portuguese according to good practice guidelines; this included the pre-test stage. In Study 2, we administered the Portuguese version to adults with and without hearing loss (n=31 and 18, respectively) and analyzed the measures of instrument validation, reliability, and reproducibility. Moreover, we calculated the correlation between pure tone thresholds and scores on the questionnaire. The results obtained in Study 1 demonstrated the feasibility of the translation process and the instrument's cultural adaptation, as well as its applicability, resulting in the Portuguese version of the Amsterdam inventory for auditory disability and handicap. In Study 2, the results revealed construct values for the questions and domains, as well as for the total reliable score. The intra-interviewer test-retest condition showed excellent reproducibility (ICC=0.97). Finally, there was a strong positive correlation (r=0.83) between the mean pure tone threshold and the hearing difficulties values, as measured by the instrument's scores. The English version of the Amsterdam inventory for auditory disability and handicap could be translated and adapted to Brazilian Portuguese. An analyses of the validation process yielded reliable, consistent, and stable results.