Pneumatic artificial muscles (PAMs) are soft and flexible linear pneumatic actuators which produce human muscle like actuation. Due to these properties, the muscle actuators have an adaptable compliance for various robotic platforms as well as medical applications. While a variety of possible actuation schemes are present, there is still a need for the development of a soft actuator that is very light-weight, compact, and flexible with high power-to-weight ratio. To achieve this, the development of the PAM actuators has become an interesting topic for many researchers. In this review, the development of the different kinds of PAM available to date are presented along with manufacturing process and the operating principle. The various force models for artificial muscle presented in the literature are broadly reviewed with the constraints. Furthermore, the applications of PAM are included and classified based on the fields of biorobotics, medicine, and industry, along with advanced medical instrumentation. Finally, the needful improvements in terms of the dynamics of the muscle are discussed for the precise control of the PAMs as per the requirements for the applications. This review will be helpful for researchers working in the field of robotics and for designers to develop new type of artificial muscle depending on the applications.
14 July 2023 in International Journal of Intelligent Robotics and Applications
In this work, the design, modeling, and development of a low-cost lower limb exoskeleton (LLES) system are presented for paediatric rehabilitation (age: 8–12 years, mass: 25–40 kg, height: 115–125 cm). The exoskeleton system, having three degrees-of-freedom (DOFs) for each limb, is designed in the SolidWorks software. A wheel support module is introduced in the design to ensure the user’s stability and safety. The finite element analysis of the hip joint connector along with the wheel support module is realized for maximum loading conditions. The holding torque capacity of exoskeleton joints is estimated using an affordable spring-based experimental setup. A working prototype of the LLES is developed with holding torque rated actuators. Thereafter, the dynamic analysis for the human-exoskeleton coupled system is carried out using the Euler-Lagrange principle and SimMechanics model. The simulation results of estimating joint actuator torques are obtained for two paraplegic subjects (Case I: 10 years age, 30 kg mass, 120 cm height and Case II: 12 years age, 40 kg mass, 125 cm height). The details of input parameters such as body mass, link lengths, joint angles, and contact forces are discussed. The simulation results of dynamic analysis have shown the potential of estimating the torques of joint actuators for the developed prototype during motion assistance and gait rehabilitation.
14 July 2021 in Journal of Intelligent & Robotic Systems
The objective of this work is to design a neuro-fuzzy compensated PID control for passive gait rehabilitation using a lower extremity exoskeleton system. A prototype of 6-DOFs exoskeleton device is developed to assist the children of age 8–10 years old. A dummy having a well-matched body attributes to a healthy child (10 years) is utilized in this work to carry out the experimental runs. Kinect-LabVIEW setup is employed to compute the desired joint angles in the sagittal plane for a healthy gait trajectory. The Euler–Lagrange method is utilized to formulate the dynamic analysis of the exoskeleton system. As the performance of existing control strategies for gait rehabilitation devices is still debatable; therefore, a robust neuro-fuzzy compensated PID control strategy is designed in this work. The asymptotic stability of the proposed control scheme is proved mathematically by Lyapunov theorem. Thereafter, the proposed control strategy is implemented on the exoskeleton-dummy setup in real-time and compared with the classical PID control strategy. From experimental runs, the root mean square error (RMSE) for proposed control scheme is found to be less by 40% nearly while tracking the desired gait trajectory. The robustness of the proposed controller is also validated by varying lower limb masses of dummy and by providing an external disturbance. It is observed that proposed controller is more robust to deal with the input disturbance as compared to parametric uncertainty. Finally, the low values of settling time in both the directions ensures the fast convergence of proposed controller.