1 April 2022 in The Journal of the Acoustical Society of America
In this article, the application of spatial covariance matching is investigated for the task of producing spatially enhanced binaural signals using head-worn microphone arrays. A two-step processing paradigm is followed, whereby an initial estimate of the binaural signals is first produced using one of three suggested binaural rendering approaches. The proposed spatial covariance matching enhancement is then applied to these estimated binaural signals with the intention of producing refined binaural signals that more closely exhibit the correct spatial cues as dictated by the employed sound-field model and associated spatial parameters. It is demonstrated, through objective and subjective evaluations, that the proposed enhancements in the majority of cases produce binaural signals that more closely resemble the spatial characteristics of simulated reference signals when the enhancement is applied to and compared against the three suggested starting binaural rendering approaches. Furthermore, it is shown that the enhancement produces spatially similar output binaural signals when using these three different approaches, thus indicating that the enhancement is general in nature and could, therefore, be employed to enhance the outputs of other similar binaural rendering algorithms.
1 February 2024 in The Journal of the Acoustical Society of America
A perceptual study was conducted to investigate the perceived accuracy of two sound-field reproduction approaches when experienced by hearing-impaired (HI) and normal-hearing (NH) listeners. The methods under test were traditional signal-independent Ambisonics reproduction and a parametric signal-dependent alternative, which were both rendered at different Ambisonic orders. The experiment was repeated in two different rooms: (1) an anechoic chamber, where the audio was delivered over an array of 44 loudspeakers; (2) an acoustically-treated listening room with a comparable setup, which may be more easily constructed within clinical settings. Ten bilateral hearing aid users, with mild to moderate symmetric hearing loss, wearing their devices, and 15 NH listeners were asked to rate the methods based upon their perceived similarity to simulated reference conditions. In the majority of cases, the results indicate that the parametric reproduction method was rated as being more similar to the reference conditions than the signal-independent alternative. This trend is evident for both groups, although the variation in responses was notably wider for the HI group. Furthermore, generally similar trends were observed between the two listening environments for the parametric method. The signal-independent approach was instead rated as being more similar to the reference in the listening room.
3 March 2022 in American Journal of Audiology
Objective: The objective of this study was to investigate the localization ability of bilateral cochlear implant (BiCI) users for virtual sound sources produced over a limited loudspeaker arrangement. Design: Ten BiCI users and 10 normal-hearing subjects participated in listening tests in which amplitude- and time-panned virtual sound sources were produced over a limited loudspeaker setup with varying azimuth angles. Three stimuli were utilized: speech, bandpassed pink noise between 20 Hz and 1 kHz, and bandpassed pink noise between 1 kHz and 8 kHz. The data were collected via a two-alternative forced-choice procedure and used to calculate the minimum audible angle (MAA) of each subject, which was subsequently compared to the results of previous studies in which real sound sources were employed. Result: The median MAAs of the amplitude-panned speech, low-frequency pink noise, and high-frequency pink noise stimuli for the BiCI group were calculated to be 20°, 38°, and 12°, respectively. For the time-panned stimuli, the MAAs of the BiCI group for all three stimuli were calculated to be close to the upper limit of the listening test. Conclusions: The computed MAAs of the BiCI group for amplitude-panned speech were marginally larger than BiCI users' previously reported MAAs for real sound sources, whereas their computed MAAs for the time-panned stimuli were significantly larger. Subsequent statistical analysis indicated a statistically significant difference in the performances of the BiCI group in localizing the amplitude-panned sources and the time-panned sources. It follows that time-panning over limited loudspeaker arrangements may not be a useful clinical tool, whereas amplitude-panning utilizing such a setup may be further explored as such. Additionally, a comparison with the patient demographics indicated correlations between the results and the patients' age at time of diagnoses and the time passed between date of diagnosis and their implant surgeries.
1 February 2025 in The Journal of the Acoustical Society of America
This study investigates the use of amplitude panning in a localization accuracy test and the influence of a non-ideal environment on its feasibility as a clinical tool. The horizontal localization accuracy of 16 normal-hearing participants and ten bilateral hearing aid users was assessed for real and amplitude panned sound sources produced over loudspeakers. Localization accuracy was measured with speech-shaped noise in both an anechoic chamber (free-field) and an acoustically treated listening room (non–free-field). The root mean square error between the response angle and the target angle was calculated for each participant. Thus, the root mean square error for the two sound source types for each test environment could be calculated and compared, and also contrasted against existing literature. Statistical analysis of the control group results revealed an effect of the target angle, method used (real vs amplitude panning) and environment (free-field vs non–free-field). An interaction between target angle and environment was also found. For the hearing aid user group, however, only an effect of target angle was found, which may lend support to simpler setups with fewer loudspeakers in non–free-field environments. However, the effect of the room varied between individuals within this group, thereby warranting further exploration.