Mara Kaufmann

Mara Kaufmann

Auto-generated profile, based on publicly available information

Mara Kaufmann

Department of Orthopaedics and Traumatology University Hospital Basel Basel Switzerland

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in Gait & Posture
Verified
Journal Article
Closed access
PIPetros Ismailidis
Petros Ismailidis
CNCorina Nüesch
Corina Nüesch
MKMara Kaufmann
Mara Kaufmann
MCMartin Clauss
Martin Clauss
GPGeert Pagenstert
Geert Pagenstert
AMAnnegret Mündermann
Annegret Mündermann

13 August 2022 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
MKMara Kaufmann
Mara Kaufmann
CNCorina Nüesch
Corina Nüesch
MCMartin Clauss
Martin Clauss
GPGeert Pagenstert
Geert Pagenstert
AEAnke Eckardt
Anke Eckardt
PIPetros Ismailidis
Petros Ismailidis
Inertial measurement units (IMUs) are commonly used for gait assessment, yet their potential for quantifying improvements in gait function and patterns after total hip arthroplasty (THA) has not been fully explored. The primary aim of this study was to compare spatiotemporal parameters and sagittal plane kinematic patterns of patients with hip osteoarthritis (OA) before and after THA, and to asymptomatic controls. The secondary aim was to assess the association between dynamic hip range of motion (ROM) during walking and the Hip Osteoarthritis Outcome Scores (HOOS). Twenty‐four patients with hip OA and 24 matched asymptomatic controls completed gait analyses using the RehaGait® sensor system. Patients were evaluated pre‐ and 1 year postoperatively, controls in a single visit. Differences in kinematic data were analyzed using statistical parametric mapping, and correlations between dynamic hip ROM and HOOS were calculated. Walking speed and stride length significantly increased (+0.08 m/s, p = 0.019; +0.06 m, p = 0.048) after THA but did not reach the level of asymptomatic controls (−0.11 m/s, p = 0.028; −0.14 m, p = 0.001). Preoperative hip and knee kinematics differed significantly from controls. After THA, they improved significantly and did not differ from controls. Dynamic hip flexion‐extension ROM correlated positively with all HOOS subscores (r > 0.417; p ≤ 0.001). The change in HOOS symptoms in patients was explained by the combination of baseline HOOS symptoms and change in dynamic hip ROM (r2 = 0.748) suggesting that the additional information gained with IMU gait analysis helps to complement and objectify patient‐reported outcome measures pre‐ and postoperatively and monitor treatment‐related improvements.