Andrew E. S. Barentine

Andrew E. S. Barentine

Auto-generated profile, based on publicly available information

Andrew E. S. Barentine

Department of Chemistry, Stanford University, Stanford, California 94305, USA

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2018 in Journal of Cell Biology
Verified
Journal Article
Open access
PDF file
LSLena K. Schroeder
Lena K. Schroeder
ABAndrew E.S. Barentine
Andrew E.S. Barentine
HMHolly Merta
Holly Merta
SSSarah Schweighofer
Sarah Schweighofer
YZYongdeng Zhang
Yongdeng Zhang
SBShirin Bahmanyar
Shirin Bahmanyar
The endoplasmic reticulum (ER) is composed of interconnected membrane sheets and tubules. Superresolution microscopy recently revealed densely packed, rapidly moving ER tubules mistaken for sheets by conventional light microscopy, highlighting the importance of revisiting classical views of ER structure with high spatiotemporal resolution in living cells. In this study, we use live-cell stimulated emission depletion (STED) microscopy to survey the architecture of the ER at 50-nm resolution. We determine the nanoscale dimensions of ER tubules and sheets for the first time in living cells. We demonstrate that ER sheets contain highly dynamic, subdiffraction-sized holes, which we call nanoholes, that coexist with uniform sheet regions. Reticulon family members localize to curved edges of holes within sheets and are required for their formation. The luminal tether Climp63 and microtubule cytoskeleton modulate their nanoscale dynamics and organization. Thus, by providing the first quantitative analysis of ER membrane structure and dynamics at the nanoscale, our work reveals that the ER in living cells is not limited to uniform sheets and tubules; instead, we suggest the ER contains a continuum of membrane structures that includes dynamic nanoholes in sheets as well as clustered tubules.

10 June 2021 in Cell
Verified
Journal Article
Closed access
ECEdward M. Courchaine
Edward M. Courchaine
ABAndrew E.S. Barentine
Andrew E.S. Barentine
KSKorinna Straube
Korinna Straube
DLDong-Ryoung Lee
Dong-Ryoung Lee
JBJoerg Bewersdorf
Joerg Bewersdorf
KNKarla M. Neugebauer
Karla M. Neugebauer

25 March 2021 in Optica
Verified
Journal Article
Open access
MVMary Grace M. Velasco
Mary Grace M. Velasco
MZMengyang Zhang
Mengyang Zhang
JAJacopo Antonello
Jacopo Antonello
PYPeng Yuan
Peng Yuan
EAEdward S. Allgeyer
Edward S. Allgeyer
OMOns Msaad
Ons Msaad
Stimulated emission depletion (STED) microscopy enables the three-dimensional (3D) visualization of dynamic nanoscale structures in living cells, offering unique insights into their organization. However, 3D-STED imaging deep inside biological tissue is obstructed by optical aberrations and light scattering. We present a STED system that overcomes these challenges. Through the combination of two-photon excitation, adaptive optics, red-emitting organic dyes, and a long-working-distance water-immersion objective lens, our system achieves aberration-corrected 3D super-resolution imaging, which we demonstrate 164 µm deep in fixed mouse brain tissue and 76 µm deep in the brain of a living mouse.

5 October 2015 in Nature Physics
Verified
Journal Article
Closed access
DLD. S. Lobser
D. S. Lobser
ABA. E. S. Barentine
A. E. S. Barentine
ECE. A. Cornell
E. A. Cornell
HLH. J. Lewandowski
H. J. Lewandowski

17 May 2021 in Nature Methods
Verified
Journal Article
Closed access
PDF file
ZMZach Marin
Zach Marin
MGMichael Graff
Michael Graff
ABAndrew E. S. Barentine
Andrew E. S. Barentine
CSChristian Soeller
Christian Soeller
KCKenny Kwok Hin Chung
Kenny Kwok Hin Chung
DBDavid Baddeley
David Baddeley

1 September 2018 in Biophysical Journal
Verified
Journal Article
Open access
ABAndrew E.S. Barentine
Andrew E.S. Barentine
LSLena K. Schroeder
Lena K. Schroeder
MGMichael Graff
Michael Graff
DBDavid Baddeley
David Baddeley
JBJoerg Bewersdorf
Joerg Bewersdorf
Reliable interpretation and quantification of cellular features in fluorescence microscopy requires an accurate estimate of microscope resolution. This is typically obtained by measuring the image of a nonbiological proxy for a point-like object, such as a fluorescent bead. Although appropriate for confocal microscopy, bead-based measurements are problematic for stimulated emission depletion microscopy and similar techniques where the resolution depends critically on the choice of fluorophore and acquisition parameters. In this article, we demonstrate that for a known geometry (e.g., tubules), the resolution can be measured in situ by fitting a model that accounts for both the point spread function (PSF) and the fluorophore distribution. To address the problem of coupling between tubule diameter and PSF width, we developed a technique called nested-loop ensemble PSF fitting. This approach enables extraction of the size of cellular features and the PSF width in fixed-cell and live-cell images without relying on beads or precalibration. Nested-loop ensemble PSF fitting accurately recapitulates microtubule diameter from stimulated emission depletion images and can measure the diameter of endoplasmic reticulum tubules in live COS-7 cells. Our algorithm has been implemented as a plugin for the PYthon Microscopy Environment, a freely available and open-source software.