Alexander Kiepas

Alexander Kiepas

Auto-generated profile, based on publicly available information

Alexander Kiepas

Department of Chemical and Biomolecular Engineering, Johns Hopkins University, Baltimore, MD 21218, USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2022 in Nature
Verified
Journal Article
Open access
PDF file
KBKaustav Bera
Kaustav Bera
AKAlexander Kiepas
Alexander Kiepas
IGInês Godet
Inês Godet
YLYizeng Li
Yizeng Li
PMPranav Mehta
Pranav Mehta
KKKonstantinos Konstantopoulos
Konstantinos Konstantopoulos
Cells respond to physical stimuli, such as stiffness1, fluid shear stress2and hydraulic pressure3,4. Extracellular fluid viscosity is a key physical cue that varies under physiological and pathological conditions, such as cancer5. However, its influence on cancer biology and the mechanism by which cells sense and respond to changes in viscosity are unknown. Here we demonstrate that elevated viscosity counterintuitively increases the motility of various cell types on two-dimensional surfaces and in confinement, and increases cell dissemination from three-dimensional tumour spheroids. Increased mechanical loading imposed by elevated viscosity induces an actin-related protein 2/3 (ARP2/3)-complex-dependent dense actin network, which enhances Na+/H+exchanger 1 (NHE1) polarization through its actin-binding partner ezrin. NHE1 promotes cell swelling and increased membrane tension, which, in turn, activates transient receptor potential cation vanilloid 4 (TRPV4) and mediates calcium influx, leading to increased RHOA-dependent cell contractility. The coordinated action of actin remodelling/dynamics, NHE1-mediated swelling and RHOA-based contractility facilitates enhanced motility at elevated viscosities. Breast cancer cells pre-exposed to elevated viscosity acquire TRPV4-dependent mechanical memory through transcriptional control of the Hippo pathway, leading to increased migration in zebrafish, extravasation in chick embryos and lung colonization in mice. Cumulatively, extracellular viscosity is a physical cue that regulates both short- and long-term cellular processes with pathophysiological relevance to cancer biology.

17 October 2022 in Nature Communications
Verified
Journal Article
Open access
PDF file
YZYuqi Zhang
Yuqi Zhang
YLYizeng Li
Yizeng Li
KTKeyata N. Thompson
Keyata N. Thompson
KSKonstantin Stoletov
Konstantin Stoletov
QYQinling Yuan
Qinling Yuan
KKKonstantinos Konstantopoulos
Konstantinos Konstantopoulos
Cell migration regulates diverse (patho)physiological processes, including cancer metastasis. According to the Osmotic Engine Model, polarization of NHE1 at the leading edge of confined cells facilitates water uptake, cell protrusion and motility. The physiological relevance of the Osmotic Engine Model and the identity of molecules mediating cell rear shrinkage remain elusive. Here, we demonstrate that NHE1 and SWELL1 preferentially polarize at the cell leading and trailing edges, respectively, mediate cell volume regulation, cell dissemination from spheroids and confined migration. SWELL1 polarization confers migration direction and efficiency, as predicted mathematically and determined experimentally via optogenetic spatiotemporal regulation. Optogenetic RhoA activation at the cell front triggers SWELL1 re-distribution and migration direction reversal in SWELL1-expressing, but not SWELL1-knockdown, cells. Efficient cell reversal also requires Cdc42, which controls NHE1 repolarization. Dual NHE1/SWELL1 knockdown inhibits breast cancer cell extravasation and metastasis in vivo, thereby illustrating the physiological significance of the Osmotic Engine Model.

13 January 2023 in Science Advances
Verified
Journal Article
Closed access
RLRobert A. Law
Robert A. Law
AKAlexander Kiepas
Alexander Kiepas
HDHabben E. Desta
Habben E. Desta
EIEmiliano Perez Ipiña
Emiliano Perez Ipiña
MPMaria Parlani
Maria Parlani
KKKonstantinos Konstantopoulos
Konstantinos Konstantopoulos
Cells tune adherens junction dynamics to regulate epithelial integrity in diverse (patho)physiological processes, including cancer metastasis. We hypothesized that the spatially confining architecture of peritumor stroma promotes metastatic cell dissemination by remodeling cell-cell adhesive interactions. By combining microfluidics with live-cell imaging, FLIM/FRET biosensors, and optogenetic tools, we show that confinement induces leader cell dissociation from cohesive ensembles. Cell dissociation is triggered by myosin IIA (MIIA) dismantling of E-cadherin cell-cell junctions, as recapitulated by a mathematical model. Elevated MIIA contractility is controlled by RhoA/ROCK activation, which requires distinct guanine nucleotide exchange factors (GEFs). Confinement activates RhoA via nucleocytoplasmic shuttling of the cytokinesis-regulatory proteins RacGAP1 and Ect2 and increased microtubule dynamics, which results in the release of active GEF-H1. Thus, confining microenvironments are sufficient to induce cell dissemination from primary tumors by remodeling E-cadherin cell junctions via the interplay of microtubules, nuclear trafficking, and RhoA/ROCK/MIIA pathway and not by down-regulating E-cadherin expression.

8 June 2023
Verified
Preprint
Open access
PDF file
CBClaire M Brown
Claire M Brown
CVCesar Leonardo Villa
Cesar Leonardo Villa
AKAlexander Kiepas
Alexander Kiepas
KPKmichiel Not Provided
Kmichiel Not Provided
ANAlexander Nowakowski
Alexander Nowakowski
APAlexander.Kiepas Not Provided
Alexander.Kiepas Not Provided
This protocol outlines in detail how to measure illumination overhead (IO) and collect raw illumination intensity data using the Rigol ds1054z oscilloscope. In fluorescence microscopy, IO is defined as the time a sample is illuminated without the emitted light being captured by the camera, resulting in unnecessary photobleaching and phototoxicity. Minimizing IO is critical for all live imaging experiments. IO occurs due to delays/errors in the synchronization between the microscope fluorescence excitation light source, exposure of the sample to excitation light and the camera exposure time for capturing emitted fluorescence light. The amount of IO varies greatly across setups due to software settings, physical hardware and how components are connected and triggered by the hardware and/or software. Thus, it is recommended that each individual measure the IO of their own microscope and experimental setup including for their exact image acquisition settings. More details use of this protocol and the need to measure IO can be found in Kiepas et. al. JCS, 2020 (https://pubmed.ncbi.nlm.nih.gov/31988150/) and Kiepas et. al. Microscopy Today, 2020 (https://www.cambridge.org/core/journals/microscopy-today/article/microscope-hardware-and-software-delays-cause-phototoxicity/B964736E4617AEC17C8B1BBD8B4F37B8)