Frank Edler

Frank Edler

Auto-generated profile, based on publicly available information

Frank Edler

Physikalisch-Technische Bundesanstalt (PTB), Abbestrasse 2-12, 10587 Berlin, Germany

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
RERené Eisermann
René Eisermann
SKStephan Krenek
Stephan Krenek
THTobias Habisreuther
Tobias Habisreuther
PEPetra Ederer
Petra Ederer
SSSigurd Simonsen
Sigurd Simonsen
ÅOÅge Andreas Falnes Olsen
Åge Andreas Falnes Olsen
Fiber Bragg gratings inscribed in single crystalline multimode sapphire fibers (S-FBG) are suitable for monitoring applications in harsh environments up to 1900 °C. Despite many approaches to optimize the S-FBG sensor, a metrological investigation of the achievable temperature uncertainties is still missing. In this paper, we developed a hybrid optical temperature sensor using S-FBG and thermal radiation signals. In addition, the sensor also includes a thermocouple for reference and process control during a field test. We analyzed the influence of the thermal gradient and hotspot position along the sensor for all three detection methods using an industrial draw tower and fixed point cells. Moreover, the signal processing of the reflected S-FBG spectrum was investigated and enhanced to determine the reachable measurement repeatability and uncertainty. For that purpose, we developed an analytical expression for the long-wavelength edge of the peak. Our findings show a higher stability against mechanical-caused mode variations for this method to measure the wavelength shift compared to established methods. Additionally, our approach offers a high robustness against aging effects caused by high-temperature processes (above 1700 °C) or harsh environments. Using temperature-fixed points, directly traceable to the International System of Units, we calibrated the S-FBG and thermocouple of the hybrid sensor, including the corresponding uncertainty budgets. Within the scope of an over 3-weeks-long field trial, 25 production cycles of an industrial silicon manufacturing process with temperatures up to 1600 °C were monitored with over 100,000 single measurements. The absolute calibrated thermocouple (Uk=2≈1K…4K) and S-FBG (Uk=2≈10K…14K) measurements agreed within their combined uncertainty. We also discuss possible strategies to significantly reduce the uncertainty of the S-FBG calibration. A follow-up measurement of the sensor after the long-term operation at high temperatures and the transport of the measuring system together with the sensor resulted in a change of less than 0.5 K. Thus, both the presented hybrid sensor and the measuring principle are very robust for applications in harsh environments.

10 October 2007 in International Journal of Thermophysics
Verified
Journal Article
Closed access
PDF file
FEF. Edler
F. Edler
PEP. Ederer
P. Ederer
ABA. C. Baratto
A. C. Baratto
HVH. D. Vieira
H. D. Vieira

29 January 2008 in International Journal of Thermophysics
Verified
Journal Article
Closed access
PDF file
FEF. Edler
F. Edler
RMR. Morice
R. Morice
JPJ. Pearce
J. Pearce

15 October 2014 in International Journal of Thermophysics
Verified
Journal Article
Closed access
PDF file
FEF. Edler
F. Edler
ELE. Lenz
E. Lenz
SHS. Haupt
S. Haupt

5 April 2022 in Measurement Science and Technology
Verified
Journal Article
Open access
PDF file
DTD J L Tucker
D J L Tucker
FEF Edler
F Edler
VŽV Žužek
V Žužek
JBJ Bojkovski
J Bojkovski
CICarmen Garcia Izquierdo
Carmen Garcia Izquierdo
NAN Arifovic
N Arifovic
Mineral insulated metal sheathed (MIMS) base metal thermocouples experience thermoelectric drift over their lifetime caused by use at high temperatures and metallurgical changes, causing spurious measurement errors. CCPI Europe Limited and University of Cambridge have designed a MIMS thermocouple with an additional inner sheath, in order to protect the thermoelements from the effects that cause thermoelectric drift. The performance of these dual-wall thermocouples and conventional type N and type K thermocouples are assessed at six different National Metrology Institutes (NMIs) using two different testing regimes: isothermal testing at 1200 °C, and thermal cycling tests between 300 °C and 1150 °C. The investigation demonstrates that in both testing regimes, the type N dual-wall thermocouples showed a significantly reduced thermoelectric drift by about a factor of three compared to the conventional thermocouples. There was no significant difference between the type K dual-wall and conventional type K thermocouples in the isothermal tests, and the type K dual-wall thermocouples showed greater drift than the conventional thermocouples in the thermal cycling tests, but the conventional type K thermocouples were less robust than the dual-wall type K thermocouples. The results presented in this paper represent an impartial assessment of the thermoelectric stability of both dual-wall thermocouples and conventional thermocouples, which may provide assurance to potential users.

23 May 2023 in Metrologia
Verified
Journal Article
Open access
FEF Edler
F Edler
Thermoelectric inhomogeneities of type S, type R and Pt-20%Rh/Pt thermocouples were determined in the temperature range between 200 °C and 1000 °C in temperature steps of 50 °C. Immersion profiles with each thermocouple at each of the 16 scanning temperatures were measured. From the measured temperature dependencies of the inhomogeneities, methods were derived how thermoelectric inhomogeneities measured at only one or two scanning temperatures are quantitatively transferred to other temperatures or temperature ranges. For this purpose, thermoelectric inhomogeneities were classified as irreversible and reversible inhomogeneities, as they must be treated differently. Irreversible thermoelectric inhomogeneities can be extrapolated linearly with temperature or electromotive force from only one immersion profile measurement at an arbitrary temperature to other temperatures in the temperature range investigated. Reversible inhomogeneities in Pt/Rh alloyed thermocouples must be taken as a kind of unavoidable background inhomogeneity (noise) whose amplitude essentially depends on the alloy composition. The distinction between reversible and irreversible inhomogeneities is made by measuring immersion profiles at two scanning temperatures: first at a temperature between 400 °C and 450 °C, where reversible inhomogeneities have a maximum value and at a temperature between 600 °C and 700 °C, where reversible inhomogeneities have a minimum in contrast to irreversible inhomogeneities.