Shanice Elisabeth Wilhelmus Janssens

Shanice Elisabeth Wilhelmus Janssens

Auto-generated profile, based on publicly available information

Shanice Elisabeth Wilhelmus Janssens

Maastricht University

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2020 in European Journal of Neuroscience
Verified
Journal Article
Open access
PDF file
TGTom A. de Graaf
Tom A. de Graaf
ATAlix Thomson
Alix Thomson
SJShanice E.W. Janssens
Shanice E.W. Janssens
SBSander van Bree
Sander van Bree
SOSanne Ten Oever
Sanne Ten Oever
ASAlexander T. Sack
Alexander T. Sack
In recent years, the influence of alpha (7–13 Hz) phase on visual processing has received a lot of attention. Magneto‐/encephalography (M/EEG) studies showed that alpha phase indexes visual excitability and task performance. Studies with transcranial alternating current stimulation (tACS) aim to modulate oscillations and causally impact task performance. Here, we applied right occipital tACS (O2 location) to assess the functional role of alpha phase in a series of experiments. We presented visual stimuli at different pre‐determined, experimentally controlled, phases of the entraining tACS signal, hypothesizing that this should result in an oscillatory pattern of visual performance in specifically left hemifield detection tasks. In experiment 1, we applied 10 Hz tACS and used separate psychophysical staircases for six equidistant tACS‐phase conditions, obtaining contrast thresholds for detection of visual gratings in left or right hemifield. In experiments 2 and 3, tACS was at EEG‐based individual peak alpha frequency. In experiment 2, we measured detection rates for gratings with (pseudo‐)fixed contrast. In experiment 3, participants detected brief luminance changes in a custom‐built LED device, at eight equidistant alpha phases. In none of the experiments did the primary outcome measure over phase conditions consistently reflect a one‐cycle sinusoid. However, post hoc analyses of reaction times (RT) suggested that tACS alpha phase did modulate RT for specifically left hemifield targets in both experiments 1 and 2 (not measured in experiment 3). This observation requires future confirmation, but is in line with the idea that alpha phase causally gates visual inputs through cortical excitability modulation.

2 December 2021 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
SJShanice E. W. Janssens
Shanice E. W. Janssens
ASAlexander T. Sack
Alexander T. Sack
Transcranial magnetic stimulation (TMS) can cause measurable effects on neural activity and behavioral performance in healthy volunteers. In addition, TMS is increasingly used in clinical practice for treating various neuropsychiatric disorders. Unfortunately, TMS-induced effects show large intra- and inter-subject variability, hindering its reliability, and efficacy. One possible source of this variability may be the spontaneous fluctuations of neuronal oscillations. We present recent studies using multimodal TMS including TMS-EMG (electromyography), TMS-tACS (transcranial alternating current stimulation), and concurrent TMS-EEG-fMRI (electroencephalography, functional magnetic resonance imaging), to evaluate how individual oscillatory brain state affects TMS signal propagation within targeted networks. We demonstrate how the spontaneous oscillatory state at the time of TMS influences both immediate and longer-lasting TMS effects. These findings indicate that at least part of the variability in TMS efficacy may be attributable to the current practice of ignoring (spontaneous) oscillatory fluctuations during TMS. Ignoring this state-dependent spread of activity may cause great individual variability which so far is poorly understood and has proven impossible to control. We therefore also compare two technical solutions to directly account for oscillatory state during TMS, namely, to use (a) tACS to externally control these oscillatory states and then apply TMS at the optimal (controlled) brain state, or (b) oscillatory state-triggered TMS (closed-loop TMS). The described multimodal TMS approaches are paramount for establishing more robust TMS effects, and to allow enhanced control over the individual outcome of TMS interventions aimed at modulating information flow in the brain to achieve desirable changes in cognition, mood, and behavior.

7 August 2021 in European Journal of Neuroscience
Verified
Journal Article
Open access
PDF file
SJShanice E. W. Janssens
Shanice E. W. Janssens
ASAlexander T. Sack
Alexander T. Sack
SOSanne Ten Oever
Sanne Ten Oever
TGTom A. de Graaf
Tom A. de Graaf
Rhythmic stimulation can be applied to modulate neuronal oscillations. Such ‘entrainment’ is optimized when stimulation frequency is individually calibrated based on magneto/encephalography markers. It remains unknown how consistent such individual markers are across days/sessions, within a session, or across cognitive states, hemispheres and estimation methods, especially in a realistic, practical, lab setting. We here estimated individual alpha frequency (IAF) repeatedly from short electroencephalography (EEG) measurements at rest or during an attention task (cognitive state), using single parieto‐occipital electrodes in 24 participants on 4 days (between‐sessions), with multiple measurements over an hour on 1 day (within‐session). First, we introduce an algorithm to automatically reject power spectra without a sufficiently clear peak to ensure unbiased IAF estimations. Then we estimated IAF via the traditional ‘maximum’ method and a ‘Gaussian fit’ method. IAF was reliable within‐ and between‐sessions for both cognitive states and hemispheres, though task‐IAF estimates tended to be more variable. Overall, the ‘Gaussian fit’ method was more reliable than the ‘maximum’ method. Furthermore, we evaluated how far from an approximated ‘true’ task‐related IAF the selected ‘stimulation frequency’ was, when calibrating this frequency based on a short rest‐EEG, a short task‐EEG, or simply selecting 10 Hz for all participants. For the ‘maximum’ method, rest‐EEG calibration was best, followed by task‐EEG, and then 10 Hz. For the ‘Gaussian fit’ method, rest‐EEG and task‐EEG‐based calibration were similarly accurate, and better than 10 Hz. These results lead to concrete recommendations about valid, and automated, estimation of individual oscillation markers in experimental and clinical settings.

16 March 2022 in NeuroImage
Verified
Journal Article
Open access
SJShanice E.W. Janssens
Shanice E.W. Janssens
SOSanne Ten Oever
Sanne Ten Oever
ASAlexander T. Sack
Alexander T. Sack
TGTom A. de Graaf
Tom A. de Graaf
Transcranial alternating current stimulation (tACS) can be used to study causal contributions of oscillatory brain mechanisms to cognition and behavior. For instance, individual alpha frequency (IAF) tACS was reported to enhance alpha power and impact visuospatial attention performance. Unfortunately, such results have been inconsistent and difficult to replicate. In tACS, stimulation generally involves one frequency, sometimes individually calibrated to a peak value observed in an M/EEG power spectrum. Yet, the 'peak' actually observed in such power spectra often contains a broader range of frequencies, raising the question whether a biologically calibrated tACS protocol containing this fuller range of alpha-band frequencies might be more effective. Here, we introduce 'Broadband-alpha-tACS', a complex individually calibrated electrical stimulation protocol. We band-pass filtered left posterior resting-state EEG data around the IAF (± 2 Hz), and converted that time series into an electrical waveform for tACS stimulation of that same left posterior parietal cortex location. In other words, we stimulated a brain region with a 'replay' of its own alpha-band frequency content, based on spontaneous activity. Within-subjects (N = 24), we compared to a sham tACS session the effects of broadband-alpha tACS, power-matched spectral inverse ('alpha-removed') control tACS, and individual alpha frequency (IAF) tACS, on EEG alpha power and performance in an endogenous attention task previously reported to be affected by alpha tACS. Broadband-alpha-tACS significantly modulated attention task performance (i.e., reduced the rightward visuospatial attention bias in trials without distractors, and reduced attention benefits). Alpha-removed tACS also reduced the rightward visuospatial attention bias. IAF-tACS did not significantly modulate attention task performance compared to sham tACS, but also did not statistically significantly differ from broadband-alpha-tACS. This new broadband-alpha-tACS approach seems promising, but should be further explored and validated in future studies.

1 February 2020 in Neuropsychologia
Verified
Journal Article
Open access
SJShanice E.W. Janssens
Shanice E.W. Janssens
ASAlexander T. Sack
Alexander T. Sack
SJSarah Jessen
Sarah Jessen
TGTom A. de Graaf
Tom A. de Graaf
As a highly social species, we constantly evaluate human faces to decide whether we can trust someone. Previous studies suggest that face trustworthiness can be processed unconsciously, but the underlying neural pathways remain unclear. Specifically, the question remains whether processing of face trustworthiness relies on early visual cortex (EVC), required for conscious perception. If processing of trustworthiness can bypass EVC, then disrupting EVC should impair subjective (conscious) trustworthiness perception while leaving objective (forced-choice) trustworthiness judgment intact. We applied double-pulse transcranial magnetic stimulation (TMS) to right EVC, at different stimulus onset asynchronies (SOAs) from presentation of a face in either the left or right hemifield. Faces were slightly rotated clockwise or counterclockwise, and were either trustworthy or untrustworthy. On each trial, participants discriminated 1) trustworthiness, 2) stimulus rotation, and 3) reported subjective visibility of trustworthiness. At early SOAs and specifically in the left hemifield, performance on the rotation task was impaired by TMS. Crucially, though TMS also impaired subjective visibility of trustworthiness, no effects on trustworthiness discrimination were obtained. Thus, conscious perception of face trustworthiness (captured by subjective visibility ratings) relies on intact EVC, while objective forced-choice trustworthiness judgments may not. These results are consistent with the hypothesis that objective trustworthiness processing can bypass EVC. For basic visual features, extrastriate pathways are well-established; but face trustworthiness depends on a complex configuration of features. Its potential processing without EVC is therefore of particular interest, further highlighting its ecological relevance.

20 June 2019 in bioRxiv
Verified
Preprint
Open access
PDF file
TGTom A. de Graaf
Tom A. de Graaf
ATAlix Thomson
Alix Thomson
SJShanice E. W. Janssens
Shanice E. W. Janssens
SBSander van Bree
Sander van Bree
SOSanne Ten Oever
Sanne Ten Oever
ASAlexander T. Sack
Alexander T. Sack
In recent years the influence of alpha (7-13 Hz) phase on visual processing has received a lot of attention. Magneto-/encephalography (M/EEG) studies showed that alpha phase indexes visual excitability and task performance. If occipital alpha phase is functionally relevant, the phase of occipital alpha-frequency transcranial alternating current stimulation (tACS) could modulate visual processing. Visual stimuli presented at different pre-determined, experimentally controlled, phases of the entraining tACS signal should then result in an oscillatory pattern of visual performance. We studied this in a series of experiments. In experiment one, we applied 10 Hz tACS to right occipital cortex (O2) and used independent psychophysical staircases to obtain contrast thresholds for detection of visual gratings in left or right hemifield, in six equidistant tACS phase conditions. In experiments two and three, tACS was at EEG-based individual peak alpha frequency. In experiment two, we measured detection rates for gratings with (pseudo-)fixed contrast levels. In experiment three, participants detected brief luminance changes in a custom-built LED device, at eight equidistant alpha phases. In none of the experiments did the primary outcome measure over phase conditions consistently reflect a one-cycle sinusoid as predicted. However, post-hoc analyses of reaction times (RT) suggested that tACS alpha phase did modulate RT in both experiments 1 and 2 (not measured in experiment 3). This observation is in line with the idea that alpha phase causally gates visual inputs through cortical excitability modulation.