PURPOSE: Endurance training improves oxidative stress and vascular endothelial dysfunction in patients with chronic heart failure (CHF). However, patients with CHF and an implantable cardioverter defibrillator (ICD) or cardiac resynchronization therapy-defibrillator (CRT-D) often avoid endurance training for fear of ICD shock. Recent studies have reported that stretching exercises enhance antioxidant activity and improve vascular responses. Therefore, we aimed to assess the effects of 4 weeks of stretching exercises on oxidative stress and vascular endothelial function in patients with CHF with an ICD or CRT-D. METHODS: Fifty sedentary patients with CHF (78% males; mean age = 70 ± 9 years; left ventricular ejection fraction = 26% ± 8%) with an ICD or CRT-D were randomly divided into a group that performed 4 weeks of stretching exercises (stretching group) and a group that continued a sedentary lifestyle (control group). We compared the reactive hyperemia peripheral arterial tonometry (RH-PAT) index and blood parameters, such as von Willebrand factor (vWF), malondialdehyde-modified low-density lipoprotein cholesterol (MDA-LDL), reactive oxygen species (ROS), high-sensitivity C-reactive protein, pentraxin 3, and fibrinogen between the 2 groups before and after the 4-week study period. RESULTS: In the stretching group, a significant increase in the RH-PAT index and significant decreases in vWF, MDA-LDL, ROS, and fibrinogen concentrations were observed after the study compared with before (all P < .05). No significant changes were observed in the control group. CONCLUSION: Four weeks of stretching exercises improved vascular endothelial dysfunction through attenuation of oxidative stress in sedentary patients with CHF with an ICD or CRT-D.
The antiarrhythmic effect of triple-site biventricular stimulation (Tri-V) is poorly understood. This study aims to evaluate the effect of cardiac resynchronization therapy (CRT) on ventricular arrhythmia (VA) with Tri-V using a single right ventricular (RV) and double left ventricular (LV) lead. Over a period of 3.5 years, 58 consecutive patients with New York Heart Association class II–IV heart failure, an LV ejection fraction of ≤0.35, and a QRS interval of ≥120 ms were enrolled. Acute haemodynamic responses to dual-site biventricular stimulation (Bi-V) and Tri-V were evaluated by assigning patients to a Bi-V or Tri-V group. Electrocardiogram parameters [QT interval, JT interval, and transmural dispersion of repolarization (TDR)] were measured over time after CRT. Spontaneous VA detected by telemetry was reviewed and confirmed. During a mean follow-up of 481 days after implantation, VA occurred in 2 of 22 patients in the Tri-V group and 14 of 36 patients in Bi-V group. Triple-site biventricular stimulation was thus associated with a decreased VA risk (P = 0.044). Multivariate Cox analysis showed that Tri-V pacing prevented arrhythmic events as compared with Bi-V pacing (hazard ratio, 0.13; 95% confidence interval, 0.029–0.610; P = 0.009). Ventricular repolarization indices at 6 months were significantly shortened in Tri-V compared with Bi-V (QTc, −23.6 vs. −14.1%, P = 0.008; JTc, −21.4 vs. −7.7%, P = 0.005; TDRc, −39.9 vs. −17.0%, P < 0.001). Compared with Bi-V, Tri-V reduced VA during long-term follow-up. Improvements in repolarization parameters may result in antiarrhythmic effects.
Although the delivery catheter system for pacemaker-lead implantation is a new alternative to the stylet system, no randomized controlled trial has addressed the difference in right ventricular (RV) lead placement accuracy to the septum between the stylet and the delivery catheter systems. This multicentre prospective randomized controlled trial aimed to prove the efficacy of the delivery catheter system for accurate delivery of RV lead to the septum. In this trial, 70 patients (mean age 78 ± 11 years; 30 men) with pacemaker indications of atrioventricular block were randomized to the delivery catheter or the stylet groups. Right ventricular lead tip positions were assessed using cardiac computed tomography within 4 weeks of pacemaker implantation. Lead tip positions were classified into RV septum, anterior/posterior edge of the RV septal wall, and RV free wall. The primary endpoint was the success rate of RV lead tip placement to the RV septum. Right ventricular leads were implanted as per allocation in all patients. The delivery catheter group had higher success rate of RV lead deployment to the septum (78 vs. 50%; P = 0.024) and narrower paced QRS width (130 ± 19 vs. 142 ± 15 ms P = 0.004) than those in the stylet group. However, there was no significant difference in procedure time [91 (IQR 68–119) vs. 85 (59–118) min; P = 0.488] or the incidence of RV lead dislodgment (0 vs. 3%; P = 0.486). The delivery catheter system can achieve a higher success rate of RV lead placement to the RV septum and narrower paced QRS width than the stylet system. jRCTs042200014 (https://jrct.niph.go.jp/en-latest-detail/jRCTs042200014) Outcome comparison between delivery catheter and stylet systems. The delivery catheter system can achieve a higher RV lead placement on the RV septum success rate and a narrower paced QRS width than the stylet system. RV, right ventricular.
Introduction Pacing-induced cardiomyopathy occasionally occurs in patients undergoing pacemaker implantation. Although compared with right ventricular (RV) apical pacing, RV septal pacing can attenuate left ventricular dyssynchrony; the success rate of lead placement on the RV septum using the stylet system is low. Additionally, no randomised controlled trial has addressed the issue regarding the accuracy of RV lead placement on the RV septum using the stylet and delivery catheter systems. This study hypothesises that a newly available delivery catheter system can improve the accuracy of RV lead placement on the RV septum. Methods and analysis In a multicentre, prospective, randomised, single-blind, controlled trial, 70 patients with pacemaker indication owing to atrioventricular block will be randomised to either the delivery catheter or stylet group before the pacemaker implantation procedure. The position of the RV lead tip will be assessed using ECG-gated cardiac CT in all patients within 4 weeks after pacemaker implantation. Lead tip positions are classified into three groups: (1) RV septum, (2) anterior/posterior edge of the RV septal wall and (3) RV free wall. The primary endpoint will be the success rate of RV lead tip placement on the RV septum, which will be evaluated using cardiac CT. Ethics and dissemination This study will be conducted according to the stipulations of the Helsinki Declaration and the institutional review board of Hamamatsu University School of Medicine. The results of the study will be disseminated at several research conferences and will be published in peer-reviewed journals. Trial registration number jRCTs042200014; Pre-results.