Mokhtar Yaghoubi

Mokhtar Yaghoubi

Auto-generated profile, based on publicly available information

Mokhtar Yaghoubi

Tehran Iran (the Islamic Republic of)

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
MYMokhtar Yaghoubi
Mokhtar Yaghoubi
JMJavad Shokrollahi Moghani
Javad Shokrollahi Moghani
NNNegar Noroozi
Negar Noroozi
MZMohammad Reza Zolghadri
Mohammad Reza Zolghadri
In this paper, a fast and practical method is proposed for open-circuit (OC) fault diagnosis (FD) in a three-phase quasi-Z-source inverter (q-ZSI). Compared to the existing fast OC FD techniques in three-phase voltage-source inverters (VSIs), this method is more cost-effective since no ultra-fast processor or high-speed measurement is required. Additionally, the method is independent of the load condition. The proposed method is only applicable to Z-source family inverters and is based on observing the effect of shoot-through (SH) intervals on the system variables during switching periods. The proposed algorithm includes two consecutive stages: OC detection and fault location identification. When both stages of the OC FD algorithm are done, a redundant leg is activated and utilized instead of the failed leg. The accuracy of the proposed method is confirmed by the experimental results from a low-voltage q-ZSI prototype.

4 September 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
NNNegar Noroozi
Negar Noroozi
MYMokhtar Yaghoubi
Mokhtar Yaghoubi
MZMohammad Reza Zolghadri
Mohammad Reza Zolghadri
The leakage current originated from the fluctuations of the common-mode voltage (CMV) is an issue in a transformerless grid-connected photovoltaic (PV) system. In this paper, a modified space vector modulation based on the Fourier transform analysis is proposed to reduce the leakage current in a three-phase quasi-Z-source inverter (qZSI). The CMV harmonic content in a qZSI contains low and high-frequency harmonics which cause safety and EMI problems respectively. By implementing the proposed modulation in a three-phase qZSI, the low-frequency harmonics of the CMV are mainly reduced. The distribution of the high-frequency harmonics is also modified in a way they can be simply filtered. Passive filtering in a qZSI using other modulation techniques is less effective than using this method. Applying the proposed modulation in the presence of a high-frequency inductive-capacitive filter results in the strong suppression of both high and low-frequency harmonics (more than 90% in the investigated case). A reduced-voltage prototype is designed to evaluate the modulation method. The experimental results from this prototype verify the accuracy of the proposed technique.

23 January 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
NNNegar Noroozi
Negar Noroozi
MYMokhtar Yaghoubi
Mokhtar Yaghoubi
MZMohammad Reza Zolghadri
Mohammad Reza Zolghadri