Mohammadamin Azimi

Mohammadamin Azimi

Auto-generated profile, based on publicly available information

Mohammadamin Azimi

Trenchless Technology Center Louisiana Tech University Ruston LA USA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

20 February 2020 in Energy Science & Engineering
Verified
Journal Article
Open access
PDF file
Liu EnbinLiu Enbin
Liu Enbin
BGBingyan Guo
Bingyan Guo
LLLiuxin Lv
Liuxin Lv
WQWeibiao Qiao
Weibiao Qiao
MAMohammadamin Azimi
Mohammadamin Azimi
In view of the complicated heat transfer calculation for air coolers and the difficulty of directly calculating the exit temperature of natural gas in a compressor station, taking the dry air cooler of model GP12 × 3‐6‐258‐13.0S‐S‐23.4/DR‐Ia configured in the West‐East Natural Gas Pipeline II as an example, a three‐dimensional simplified model of the air cooler is established. The model is used to simulate a temperature flow field of a dry air cooler‐finned tube based on Fluent flow field analysis software. This paper studies the cooling effect of the dry air cooler‐finned tube on high‐temperature and high‐pressure natural gas at compressor outlet. By comparing and analyzing the relationships among natural gas mass flow, inlet air temperature, inlet natural gas temperature, and outlet natural gas temperature for an air cooler, the formula of temperature drop of dry air cooler to natural gas is fitted, and the fitting formula is verified by field operation data. The results show that the average error between the fitting results and the actual data is less than 1.5%, which proves the correctness of the fitting formula and greatly simplifies the heat transfer calculation process for air coolers.

1 August 2023 in Journal of Pipeline Systems Engineering and Practice
Verified
Journal Article
Closed access
HLHongfang Lu
Hongfang Lu
HPHaoyan Peng
Haoyan Peng
ZXZhao-Dong Xu
Zhao-Dong Xu
GQGuojin Qin
Guojin Qin
MAMohammadamin Azimi
Mohammadamin Azimi
LCLi Cao
Li Cao

23 February 2016 in Advances in Structural Engineering
Verified
Journal Article
Closed access
MAMohammadamin Azimi
Mohammadamin Azimi
ABAsma Bagherpourhamedani
Asma Bagherpourhamedani
MTMahmood Md. Tahir
Mahmood Md. Tahir
ASAbdul Rahman Bin Mohd Sam
Abdul Rahman Bin Mohd Sam
CMChau-Khun Ma
Chau-Khun Ma
Using continuous spiral reinforcements can greatly improve the seismic performance of reinforced concrete columns, in terms of ductility and energy dissipation capacity. The simultaneous incorporation of this method in beams and columns might influence the behaviour of beam–column connections as wide spectrums of brittle failure were observed in this region. A new proposed beam–column connection introduced as ‘twisted opposing rectangular spiral’ was investigated in this research in both experimental and numerical manners along with comparing its seismic performance with both normal rectangular spiral and conventional shear reinforcement systems. The design of three full-scale beam–column connections was performed according to Eurocode (EC8-04) for high ductility classes, and the quasi-static cyclic loading recommended by American Concrete Institute Building Code (ACI 318-08) was hired to conduct the seismic tests. Finally, the experimental results were validated by numerical results obtained from the finite element analysis of the three specimens. The results revealed improved ultimate lateral resistant, energy dissipation capacity and ductility for the new proposed connection.

1 January 2014 in The Scientific World Journal
Verified
Journal Article
Open access
PDF file
MAMohammadamin Azimi
Mohammadamin Azimi
AAAzlan Bin Adnan
Azlan Bin Adnan
ASAbdul Rahman Bin Mohd Sam
Abdul Rahman Bin Mohd Sam
MTMahmood Md Tahir
Mahmood Md Tahir
Iman FaridmehrIman Faridmehr
Iman Faridmehr
RHReza Hodjati
Reza Hodjati
The seismic performance of RC columns could be significantly improved by continuous spiral reinforcement as a result of its adequate ductility and energy dissipation capacity. Due to post-earthquake brittle failure observations in beam-column connections, the seismic behaviour of such connections could greatly be improved by simultaneous application of this method in both beams and columns. In this study, a new proposed detail for beam to column connection introduced as “twisted opposing rectangular spiral” was experimentally and numerically investigated and its seismic performance was compared against normal rectangular spiral and conventional shear reinforcement systems. In this study, three full scale beam to column connections were first designed in conformance with Eurocode (EC2-04) for low ductility class connections and then tested by quasistatic cyclic loading recommended by ACI Building Code (ACI 318-02). Next, the experimental results were validated by numerical methods. Finally, the results revealed that the new proposed connection could improve the ultimate lateral resistance, ductility, and energy dissipation capacity.

1 August 2015 in Latin American Journal of Solids and Structures
Verified
Journal Article
Open access
PDF file
MAMohammadamin Azimi
Mohammadamin Azimi
AAAzlan Bin Adnan
Azlan Bin Adnan
MTMahmood Md. Tahir
Mahmood Md. Tahir
Abdul Rahman Mohd SamAbdul Rahman Mohd Sam
Abdul Rahman Mohd Sam
SRSk Muiz Bin Sk Abd Razak
Sk Muiz Bin Sk Abd Razak
The seismic performance of RC columns can considerably be improved through the use of continuous spiral reinforcement in terms of ductility and energy dissipation capacity. Since the beam-column connections were subjected to brittle failure after earthquakes, the simultaneous application of this method in both beams and columns could greatly improve the seismic behaviour of such connections. In this investigation, a new proposed detail for beam to column connection introduced as "twisted opposing rectangular spiral" was investigated both experimentally and numerically and its seismic performance was verified through comparison with normal rectangular spiral and conventional shear reinforcement systems. In this research, three full scale beam to column connections were first designed according to Eurocode (EC8-04) for Medium ductility classes and then tested by quasi-static cyclic loading suggested by ACI Building Code (ACI 318-08). Finally, numerical methods were hired to validate the experimental results. The results indicated that the ultimate lateral resistance, ductility and energy dissipation capacity of the connection could be improved using the new proposed connection.