Atul Garg

Atul Garg

Auto-generated profile, based on publicly available information

Atul Garg

Department of Microbiology, Sanjay Gandhi Postgraduate Institute of Medical Sciences (SGPGIMS) , Lucknow

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 November 2020 in Journal of Medical Virology
Verified
Journal Article
Open access
PDF file
AGAtul Garg
Atul Garg
UGUjjala Ghoshal
Ujjala Ghoshal
SPSangram S. Patel
Sangram S. Patel
DSD. V. Singh
D. V. Singh
AAAkshay K. Arya
Akshay K. Arya
NSNikki Srivastava
Nikki Srivastava
There are more than 350 real‐time polymerase chain reaction (RT‐PCR) coronavirus disease‐2019 (COVID‐19) testing kits commercially available but these kits have not been evaluated for pooled sample testing. Thus, this study was planned to compare and evaluate seven commercially available kits for pooled samples testing. Diagnostic accuracy of (1) TRUPCR SARS‐CoV‐2 Kit (Black Bio), (2) TaqPath RT‐PCR COVID‐19 Kit (Thermo Fisher Scientific), (3) Allplex 2019‐nCOV Assay (Seegene), (4) Patho detect COVID‐19 PCR kit (My Lab), (5) LabGun COVID‐19 RT‐PCR Kit (Lab Genomics, Korea), (6) Fosun COVID‐19 RT‐PCR detection kit (Fosun Ltd.), (7) Real‐time Fluorescent RT‐PCR kit for SARS CoV‐2 (BGI) was evaluated on precharacterised 40 positive and 10 negative COVID‐19 sample pools. All seven kits detected all sample pools with low Ct values (30); the TRUPCR Kit, TaqPath Kit, Allplex Assay, and BGI RT‐PCR kit showed 100% sensitivity, specificity, and accuracy. However, the Fosun kit, LabGun Kit, and Patho detect kit could detect only 90%, 85%, and 75% of weakly positive samples, respectively. We conclude that all seven commercially available RT‐PCR kits included in this study can be used for routine molecular diagnosis of COVID‐19. However, regarding performing pooled sample testing, it might be advisable to use those kits that performed best regarding positive identification in samples' pool, that is TRUPCR SARS‐CoV‐2 Kit, TaqPath RT‐PCR COVID‐19 Kit, Allplex 2019‐nCOV Assay, and BGI Real‐time RT‐PCR kit for detecting SARS CoV‐2.

1 January 2019 in Journal of Laboratory Physicians
Verified
Journal Article
Open access
PDF file
AGAtul Garg
Atul Garg
JGJaya Garg
Jaya Garg
DSDharam Veer Singh
Dharam Veer Singh
TDTn Dhole
Tn Dhole
BACKGROUND: Dengue virus infection is an important emerging disease of the tropical and subtropical regions and is mainly diagnosed by serological detection of NS1 antigen and IgM antidengue antibodies. Since enzyme-linked immunosorbent assay (ELISA) facilities are not easily available at most diagnostic centers, so most of them use various commercially available rapid diagnostic tests (RDTs) kits. AIMS AND OBJECTIVES: This study was designed to access the diagnostic accuracy of four commercially available and widely used RDTs for serodiagnosis of dengue virus infection in Indian laboratories. SUBJECTS AND METHODS: The study was conducted at Department of Microbiology, G.S.V.M Medical College, Kanpur, India, to estimate the sensitivity and specificity of following RDTs: (1) Dengue Cassette (Panbio, Australia), (2) Bioline Dengue Duo (SD Diagnostics, Korea), (3) Dengue Day 1 test (J Mitra and Co., India), and (4) Dengucheck Duo (Tulip Diagnostics, India) on 72 confirmed dengue serum samples that were positive by dengue reverse transcription-polymerase chain reaction, dengue NS1, and IgM ELISA along with 80 serum samples from nondengue febrile illness patients. RESULTS: The majority of the RDTs demonstrated low sensitivity but good specificity for detecting NS1 antigen. Detection of antidengue IgM antibodies by RDTs demonstrated low sensitivity ranging from 27.8% to 77.7%. However, specificity was generally higher (50%–86.2%) and more consistent across the assays. CONCLUSION: The study results differed markedly from the RDTs manufacturers’ claimed performance characteristics. Therefore, the RDT results should be interpreted cautiously and ELISA should be performed as far as possible for serodiagnosis of dengue virus infection.

13 October 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
UGUjjala Ghoshal
Ujjala Ghoshal
AGAtul Garg
Atul Garg
SVShruthi Vasanth
Shruthi Vasanth
AAAkshay K. Arya
Akshay K. Arya
APAnkita Pandey
Ankita Pandey
VSVikram P. Singh
Vikram P. Singh
COVID-19 testing is required before admission of a patient in the hospitals, invasive procedures, major and minor surgeries etc. Real Time Polymerase chain reaction is the gold standard test for the diagnosis, but requires well equipped biosafety laboratory along with trained manpower. In this study we have evaluated the diagnostic accuracy of novel TrueNat molecular assay for detecting SARS CoV-2. TrueNat is a chip-based real time PCR test and works on portable, light weight, battery powered equipment and can be used in remote areas with poor infrastructure. In this study 1807 patients samples were collected for both TrueNat and RTPCR COVID-19 testing during study period. Of these 174 (9.7%) and 174 (15%) were positive by RTPCR and TrueNat respectively and taking results of RTPCR as gold standard TrueNat test showed a sensitivity, specificity and diagnostic accuracy of 69.5, 90.9% and 89.2% respectively. It can be concluded that TrueNat is a simple, easy to use, good rapid molecular diagnostic test for diagnosis of COVID-19 especially in resource limited settings and will prove to be a game changer of molecular diagnostics in future.

22 October 2020 in Disaster Medicine and Public Health Preparedness
Verified
Journal Article
Open access
PDF file
SSSai Saran
Sai Saran
MGMohan Gurjar
Mohan Gurjar
AGAtul Garg
Atul Garg
During the current coronavirus disease (COVID-19) pandemic, it is estimated that tens of thousands of health care workers have been infected. The doffing of personal protective equipment (PPE) has been identified an important place and procedure that might influence the self-contamination of health care workers. More recent evidence suggests that, in addition to existing infection control standards, there is an urgent need for the incorporation of various recent information and advancements pertaining to structure and process to reduce the self-contamination of health care workers during the doffing of PPE.

1 November 2023 in The Journal of Clinical Endocrinology & Metabolism
Verified
Journal Article
Closed access
PDF file
JMJayakrishnan C Menon
Jayakrishnan C Menon
PSPratibha Singh
Pratibha Singh
AAArchana Archana
Archana Archana
PSPreeti Singh
Preeti Singh
MMMedha Mittal
Medha Mittal
EBEesh Bhatia
Eesh Bhatia
Background While the frequency of islet antibody-negative (idiopathic) type 1 diabetes mellitus (T1DM) is reported to be increased in Indian children, its aetiology is not studied. We investigated the role of monogenic diabetes in the causation of islet antibody-negative T1DM. Methods We conducted a multicentre, prospective, observational study of 169 Indian children (age 1-18 years) with recent-onset T1DM. All were tested for antibodies against GAD65, islet antigen-2 and zinc transporter 8, using validated ELISA. Thirty-four islet antibody-negative children underwent targeted next-generation sequencing for 31 genes implicated in monogenic diabetes using the Illumina platform. All mutations were confirmed by Sanger sequencing. Results Thirty-five (21%) children were negative for all islet antibodies. Twelve patients (7% of entire cohort, 34% of patients with islet antibody-negative T1DM) were detected to have pathogenic or likely pathogenic genetic variants. The most frequently affected locus was WFS1, with 9 patients (5% of entire cohort, 26% of islet antibody-negative). These included 7 children with homozygous, and 1 patient each with a compound heterozygous and heterozygous mutation. Children with Wolfram syndrome 1 (WS) presented with severe insulin-requiring diabetes (including 3 patients with ketoacidosis), but other syndromic manifestations were not detected. In 3 patients, heterozygous mutations in HNF4A, ABCC8 and PTF1A loci were detected. Conclusions Nearly one-quarter of Indian children with islet antibody-negative T1DM had recessive mutations in the WFS1 gene. These patients did not exhibit other features of WS at the time of diagnosis. Testing for monogenic diabetes, especially WS, should be considered in Indian children with antibody-negative T1DM.

1 May 2021 in Indian Journal of Medical Research
Verified
Journal Article
Open access
JGJaya Garg
Jaya Garg
AGAtul Garg
Atul Garg
Indian J Med Res, Official publication of Indian Council of Medical Research,India