Mary Ensch

Mary Ensch

Auto-generated profile, based on publicly available information

Mary Ensch

Department of Chemical Engineering and Materials Science Michigan State University East Lansing MI USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2020 in Water and Environment Journal
Verified
Journal Article
Closed access
PDF file
MEMary Ensch
Mary Ensch
CRCory Rusinek
Cory Rusinek
MBMichael F. Becker
Michael F. Becker
TSThomas Schuelke
Thomas Schuelke

23 January 2018 in Analytical Chemistry
Verified
Journal Article
Closed access
MEMary Ensch
Mary Ensch
VMVanessa Y. Maldonado
Vanessa Y. Maldonado
GSGreg M. Swain
Greg M. Swain
RRRobert Rechenberg
Robert Rechenberg
MBMichael F. Becker
Michael F. Becker
CRCory Rusinek
Cory Rusinek

1 June 2020 in The Electrochemical Society Interface
Verified
Journal Article
Open access
PDF file
SWSuzanne Witt
Suzanne Witt
NRNick Rancis
Nick Rancis
MEMary Ensch
Mary Ensch
VMVanessa Maldonado
Vanessa Maldonado
Per- and polyfluoroalkyl substances (PFAS) are manmade compounds used in a variety of industrial applications, and their consumption by humans can lead to many adverse health effects. Due to their high stability, destroying PFAS once they have contaminated water streams has become a major challenge. One promising remediation method is electrochemical oxidation (EO). To perform EO, electrode materials that can withstand high current and voltage conditions are required. Boron-doped diamond (BDD) is one such material, and its viability has been demonstrated for the EO of PFAS in a custom water treatment system applied and optimized to high-strength waste streams laden with PFAS. The permanent and disruptive nature of the technology lends itself to applicability in complex media such as IX regenerates, RO rejects, aqueous film forming foam (AFFF), industrial wastewaters, and landfill leachates, among others.

1 April 2019 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
MEMary Ensch
Mary Ensch
BWBettina Wehring
Bettina Wehring
GLGreg D. Landis
Greg D. Landis
EGElias Garratt
Elias Garratt
MBMichael F. Becker
Michael F. Becker
CRCory Rusinek
Cory Rusinek

1 May 2020 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
MEMary Ensch
Mary Ensch
EDEmma Davis
Emma Davis
GLGreg D. Landis
Greg D. Landis
VMVanessa Y. Maldonado
Vanessa Y. Maldonado
MBMichael F Becker
Michael F Becker
TSThomas Schuelke
Thomas Schuelke
Per- and Polyfluoroalkyl substances (PFAS) are a group of manmade chemicals which are persistent in the environment and have shown to be toxic to human health. They have accumulated in drinking water, groundwater, and wastewater around the globe for over six decades. Although the production of some chain lengths has ceased, remediation is critical. Current remediation techniques include adsorbents such as granular activated carbon (GAC) and Ion exchange (IX) columns. GAC is merely used to adsorb the PFAS, but struggles with capturing shorter chains and requires regeneration with incineration.1 IX has shown improvement in its ability to capture all PFAS chain lengths, and can be regenerated with a solution comprised of a salt or base and an alcohol.1 This regenerate solution desorbs all of the PFAS from the resin into a smaller concentrated solution of roughly a few hundred gallons. This solution is typically comprised of PFAS in the parts per million (ppm) range.2 These concentrated PFAS solutions can lead to further contamination of the environment through discharge of landfill leachate to wastewater treatment plants from landfill disposal. Due to the high salinity, low volume, and high concentration of PFAS in IX regenerate solutions, electrochemical oxidation is a promising treatment technology to destroy the PFAS and remove the chance of future human exposure. This study employs a boron-doped diamond (BDD) on niobium (Nb) electrode stack to investigate the role that current density has in the electrochemical destruction of PFAS in a complex solution matrix. The electrode stack was comprised of two anode plates sandwiched in between three cathode plates. This entire stack was then placed into a constantly stirred reactor comprised of 750 ml of solution. A constant current density of 50 mA/cm2 was investigated initially for a total of 12 hours. In order to save on energy consumption, further studies used a combined current density approach. This involved applying 50 mA/cm2 for only the first hour of the test before lowering the current density to 5 mA/cm2 for the remaining 11 hours. Multiple literature IX regenerate solutions were simulated and spiked with perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS).3–6 Multiple samples were taken over the course of the oxidation experiments and sent for PFAS analysis using the Environmental Protection Agency’s (EPA) modified 537 method. Additional process parameters were monitored over time including the pH, voltage, temperature, and the reduction in chemical oxygen demand (COD) and ammonia depending on the simulated regenerate solution used. Further analysis showed a significant reduction in energy with a minimal additional amount of PFAS remaining in the initial combined current density study compared to the traditional constant current density approach. 1. Woodard, S., Berry, J. & Newman, B. Ion exchange resin for PFAS removal and pilot test comparison to GAC. Remediation 27, 19–27 (2017). 2. Liang, S., Pierce, R. “David”, Lin, H., Chiang, S. Y. D. & Huang, Q. “Jack”. Electrochemical oxidation of PFOA and PFOS in concentrated waste streams. Remediation 28, 127–134 (2018). 3. Conte, L., Falletti, L., Zaggia, A. & Milan, M. Polyfluorinated Organic Micropollutants Removal from Water by Ion Exchange and Adsorption. in CHEMICAL ENGINEERING TRANSACTIONS 43, (2015). 4. Zaggia, A., Conte, L., Falletti, L., Fant, M. & Chiorboli, A. Use of strong anion exchange resins for the removal of perfluoroalkylated substances from contaminated drinking water in batch and continuous pilot plants. Water Res. 91, 137–146 (2016). 5. Chularueangaksorn, P., Tanaka, S., Fujii, S. & Kunacheva, C. Regeneration and reusability of anion exchange resin used in perfluorooctane sulfonate removal by batch experiments. J. Appl. Polym. Sci. 130, 884–890 (2013). 6. Deng, S., Yu, Q., Huang, J. & Yu, G. Removal of perfluorooctane sulfonate from wastewater by anion exchange resins: Effects of resin properties and solution chemistry. Water Res. 44, 5188–5195 (2010).