1 October 2018 in IEEE Sensors Journal
Pose tracking based on a permanent magnet is not limited by line-of-sight. In general, a high-remanence and axially magnetized cylindrical permanent magnet is utilized as the magnetic source, which is regarded as a magnetic dipole model. However, this magnetic tracking approach cannot estimate the rotation information along the direction of the magnetic moment. Thus, only three-dimensional (3D) linear motion and 2D rotational motion of the magnet can be tracked. On the other hand, inertial sensors provide effective 3D orientation tracking. In this study, an inertial measurement unit was attached on the surface of a permanent magnet. Then the tracking information of these two modes was fused based on the adaptive weighted fusion algorithm. Experiments show that the full 6D pose is acquired with an improved orientation accuracy, where the average orientation errors for α, β, and γ, obtained by the fusion algorithm, were 0.81°, 0.93°, and 1.26°, respectively. This study is helpful to those who want to accurately track the full 6D pose of an object.
11 May 2018 in IEEE Access
Accurate evaluation of bradykinesia plays a crucial role in the diagnosis and therapy effect of Parkinson’s disease (PD). However, the subjective assessment shows low consistency among different evaluators, and the objective sensor-based methods cannot accurately distinguish patients with different grades of the 5-point clinical bradykinesia ratings. In this study, an objective scoring method based on axis-angle representation and multi-class support vector machine (SVM) classifier was employed to estimate the bradykinesia severity. To reduce the dimension of attitude data for the better statistical analysis, the axis-angle representation approach was employed to obtain the 1-dimensional (1D) combined orientation angle to express the 3D hand-grasping assessment task. The significant bradykinesia features extracted from the 1-D combined orientation angle were used to train the SVM classification algorithm to acquire an objective score on the bradykinesia severity. Clinical experiments with 78 patients and 18 age-matched healthy subjects showed that the classification accuracy of the proposed method was 95.349%, which was superior to other related reports. Hence, the proposed objective scoring method can provide a 5-point bradykinesia score in real-time, and matches the clinical assessment approach of neurologists. Moreover, this method improves both the inter-rater reliability and intra-rater reliability of the bradykinesia assessment.